PTA Balloon Catheter
FDA Clearance Information
The PTA balloon catheter by Cook was cleared via the FDA 510k pathway on October 22, 2003. It is classified as a Class 2 device under product code DQY.
What It Is
FDA-Cleared Indications
- Used for percutaneous transluminal angioplasty of narrowed or obstructed peripheral blood vessels.
- Intended to restore or improve blood flow through stenotic peripheral vasculature.
- Use is governed by the specific catheter model's FDA-cleared labeling, including its indicated vessel sizes and treatment locations.
Clinical Applications
- Balloon angioplasty of stenotic peripheral arteries.
- Treatment of peripheral vascular narrowing that limits blood flow.
- Angioplasty of selected venous or dialysis-access lesions when permitted by the specific product labeling.
- Balloon dilation performed during an endovascular procedure under fluoroscopic imaging.
Reported off-label uses
- Balloon dilation of selected venous stenoses outside the device's labeled vascular territory.
- Angioplasty of thrombosed or dysfunctional arteriovenous dialysis access as part of an access-maintenance procedure.
- Balloon preparation or post-dilation of a lesion during selected peripheral or venous stent procedures.
Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.
Evidence Summary
Reported Outcomes
Safety Profile
Evidence Limitations
Practical Considerations
- Available balloon diameters, lengths, shaft configurations and rated burst pressures vary by model; select the catheter for the target vessel and lesion.
- The catheter must be compatible with the guidewire, introducer sheath and contrast-injection system specified in its labeling.
- Use fluoroscopic or other appropriate imaging guidance, and inflate the balloon only with the recommended contrast-saline mixture and within labeled pressure limits.
- Contraindications and precautions include inability to cross the lesion, severe vessel tortuosity, uncorrected coagulation problems, contrast allergy or significant renal impairment when contrast is required.
- MRI safety depends on the exact catheter model and whether it remains in the patient; check the current manufacturer labeling before MRI. Most angioplasty catheters are single-use devices and are removed after the procedure.
Procedures that use this device
Frequently Asked Questions
What are the clinical indications for PTA balloon catheter?
The PTA balloon catheter is indicated for use in percutaneous transluminal angioplasty to treat vascular stenosis, particularly in arteriovenous access and peripheral artery disease.
What outcomes have been reported in clinical studies?
Studies have reported effective management of vascular stenosis, with reduced procedure time and contrast use compared to standard methods.
What complications have been reported?
Reported complications include potential vessel injury or restenosis, though specific safety data from the evidence is limited.