Stent Graft Balloon Catheter
Via Biomedical
FDA Clearance Information
The stent graft balloon catheter was cleared by the FDA through the 510(k) pathway on October 15, 2009. It is manufactured by Via Biomedical and classified as a Class 2 device.
What It Is
FDA-Cleared Indications
- For percutaneous placement and expansion of a stent graft within a blood vessel.
- For treatment of vascular stenosis or occlusion when endovascular stent-graft placement is clinically appropriate.
- For maintaining or restoring patency of vascular access, including hemodialysis access, according to the specific device labeling.
Clinical Applications
- Endovascular placement and balloon expansion of a vascular stent graft.
- Treatment of stenosis in a vascular access circuit used for hemodialysis.
- Treatment of selected venous stenoses or occlusions requiring covered stent placement.
- Percutaneous maintenance or restoration of vascular access patency.
Reported off-label uses
- Treatment of selected central venous stenoses outside the device's specific labeled indication.
- Use in venous stenting procedures involving iliac or other large veins when the device is not specifically labeled for that anatomy.
Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.
Evidence Summary
Reported Outcomes
Safety Profile
Evidence Limitations
Practical Considerations
- The catheter, guidewire, sheath, and stent-graft dimensions must be compatible with the target vessel and the planned access route.
- Use requires fluoroscopic or other appropriate imaging guidance, sterile technique, and careful vessel sizing before deployment.
- Balloon inflation pressure and duration must follow the device instructions for use; excessive inflation can injure the vessel or damage the stent graft.
- MRI conditions depend on the specific stent-graft and catheter components. The implanted stent graft should be evaluated using its current labeling before an MRI examination.
- Contraindications and precautions include unsuitable vessel size or anatomy, inability to safely obtain vascular access, active infection at the treatment site, and allergy or intolerance to contrast or device materials.
Procedures that use this device
Frequently Asked Questions
What are the clinical indications for stent graft balloon catheter?
The device is indicated for use in maintaining vascular access, particularly in patients requiring hemodialysis, and in treating venous stenosis.
What outcomes have been reported in clinical studies?
Clinical studies have reported successful maintenance of vascular access patency and effective treatment of stenosis, with technical success in multiple cases.
What complications have been reported?
Safety data from evidence indicate potential complications such as stent migration and vessel injury, though these are relatively infrequent.