Concentric Balloon Guide Catheter
Concentric Medical
FDA Clearance Information
The concentric balloon guide catheter was cleared by the FDA through the 510(k) pathway on November 17, 2010. It is manufactured by Concentric Medical and classified as a Class 2 device.
What It Is
FDA-Cleared Indications
- Provides vascular access and support for the introduction of interventional devices into the peripheral and neurovascular systems.
- Is intended for use during endovascular procedures requiring catheter-based access to blood vessels.
- The specific cleared indication depends on the complete device labeling and instructions for use.
Clinical Applications
- Endovascular access and support during selected neurovascular interventions.
- Endovascular access and support during selected peripheral vascular interventions.
- Temporary balloon occlusion or flow control when specified by the device labeling and procedure plan.
- Delivery or exchange support for compatible therapeutic catheters and devices.
Reported off-label uses
- Proximal flow arrest and aspiration support during mechanical thrombectomy for acute ischemic stroke, when used outside the exact indications in the device labeling.
- Temporary flow control during complex venous thrombectomy or other peripheral endovascular procedures when the use is not specifically included in the labeling.
Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.
Evidence Summary
Reported Outcomes
Safety Profile
Evidence Limitations
Practical Considerations
- The catheter must be matched to the target vessel, guidewire, sheath, and therapeutic device by diameter, length, and compatibility.
- Balloon inflation requires careful monitoring of the recommended inflation medium, volume, pressure, and vessel diameter; overinflation can injure the vessel or rupture the balloon.
- Use fluoroscopic or other appropriate imaging guidance, with attention to vessel tortuosity, spasm, dissection, thrombus, and difficult access.
- MRI safety is model-specific. Confirm the exact device's MR Safe, MR Conditional, or MR Unsafe status before MRI; do not assume all balloon guide catheters have the same classification.
- Potential complications include bleeding or hematoma at the access site, vessel injury, thrombosis, embolization, infection, balloon rupture, and complications related to contrast or sedation.
Procedures that use this device
Frequently Asked Questions
What are the clinical indications for concentric balloon guide catheter?
The device is indicated for use in neurovascular and peripheral vascular interventions, particularly in thrombectomy procedures.
What outcomes have been reported in clinical studies?
Studies have reported successful outcomes in complex thrombectomy cases and aneurysm treatments using the device.
What complications have been reported?
Safety data indicate complications such as difficult catheterization due to vessel anatomy, but no major adverse events were reported.