📋 FDA Reference

Cordis Cath Sheath Introduc Mid-Length Sheath Syst

Cordis US Corp.

Contact Cordis US Corp. ↗ Compare similar devices

Summary: The Cordis Cath Sheath Introducer Mid-Length Sheath System is a medical device used to facilitate the introduction of catheters and other devices into the vascular system. It is primarily used by interventional cardiologists and radiologists.

FDA Clearance Information

Pathway ? 510(k)
Number ? K861082 ↗
Decision Date ? May 5, 1986
Product Code ? DYB
Device Class ? Class 2
Evidence ? 0 studies

The Cordis Cath Sheath Introducer Mid-Length Sheath System was cleared through the FDA 510(k) pathway on May 5, 1986. Manufactured by Cordis, this device is classified as Class 2 under product code DYB.

What It Is

The Cordis Cath Sheath Introducer Mid-Length Sheath System is a vascular access device designed to aid in the insertion of catheters into the bloodstream. It consists of a sheath and dilator that provide a stable and secure entry point into the vascular system, minimizing trauma to the vessel. This system is essential for procedures requiring catheterization, such as angiography or the deployment of embolization coils.

FDA-Cleared Indications

  • Facilitates percutaneous introduction of catheters and other intravascular devices into the vascular system.
  • Provides vascular access during diagnostic and interventional catheter-based procedures.
  • Supports the passage and exchange of compatible catheters or devices while maintaining access to the vessel.

Clinical Applications

  • Vascular access for angiography and other diagnostic imaging procedures.
  • Access for catheter-based vascular interventions, including angioplasty and stent procedures.
  • Access for embolization procedures when compatible catheters or embolic delivery systems are used.
  • Temporary access for introducing and exchanging compatible intravascular devices.

Reported off-label uses

  • Use as an access sheath for specialized neurointerventional procedures when the sheath specifications are appropriate.
  • Use for selected venous interventions or other catheter-based procedures outside the original labeled application, based on clinician judgment and device compatibility.

Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.

Practical Considerations

  • The sheath and dilator must be selected to match the target vessel, access site, catheter diameter and procedural requirements.
  • The system is intended for temporary procedural use; it is not an implant designed to remain in the vessel after the procedure.
  • Use sterile technique and appropriate imaging guidance, such as ultrasound and fluoroscopy, to reduce the risk of bleeding, vessel injury, infection and malposition.
  • Confirm compatibility with the guidewire, catheter and other devices before use; excessive force can damage the vessel or device.
  • MRI safety depends on the exact model and materials. Because this record does not provide model-specific MRI labeling, consult the current Cordis instructions for use and MRI conditions before scanning.

Procedures that use this device

Frequently Asked Questions

What is the Cordis Cath Sheath Introducer Mid-Length Sheath System used for?

It is used to facilitate the introduction of catheters and other devices into the vascular system for diagnostic and therapeutic procedures.

What specialties typically use this device?

Interventional cardiologists and radiologists commonly use this device in procedures requiring vascular access.

What are the FDA-cleared indications?

The device is indicated for providing vascular access for catheter-based interventions in patients requiring diagnostic or therapeutic procedures.

Disclaimer: This page compiles publicly available regulatory and published clinical evidence for educational reference. It does not constitute medical advice, product endorsement, or a recommendation for clinical use. Always consult manufacturer documentation and clinical judgment for patient care decisions.