Cordis Catheter Sheath Introducer
FDA Clearance Information
The Cordis Catheter Sheath Introducer was cleared via the FDA 510(k) pathway on August 26, 1993. It is manufactured by Cordis and classified as a Class 2 device.
What It Is
FDA-Cleared Indications
- Introduction of catheters into the vascular system.
- Maintenance of vascular access during catheter-based procedures.
- Use when a hemostatic valve is needed to reduce blood loss during catheter insertion and exchange.
Clinical Applications
- Establishing access for central venous catheterization.
- Supporting hemodynamic monitoring through vascular catheters.
- Providing access for infusion of multiple solutions or medications.
- Maintaining catheter access during diagnostic or interventional vascular procedures.
Reported off-label uses
- Providing arterial access for embolization and other endovascular interventions when the selected sheath size and configuration are appropriate.
- Maintaining access during neurointerventional procedures such as aneurysm coiling or AVM embolization when used according to institutional practice.
- Providing access during transjugular procedures, including portal venous interventions, when the device is compatible with the planned technique.
Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.
Evidence Summary
Reported Outcomes
Safety Profile
Evidence Limitations
Practical Considerations
- Available sizes, lengths, dilators, and catheter compatibility should be confirmed for the planned procedure; the appropriate size depends on the catheter or devices that must pass through it.
- The access site may be central venous, peripheral venous, or arterial depending on the procedure and the specific labeled configuration. Use sterile technique and imaging guidance when clinically appropriate.
- The hemostatic valve reduces blood loss but does not eliminate bleeding, air entry, thrombosis, infection, vascular injury, or hematoma risk.
- MRI safety depends on the exact model and whether the sheath remains in place; confirm the product-specific MRI labeling before scanning.
- This is generally a temporary access device rather than a long-term implant. Avoid use when the access route is unsuitable or when the patient has a contraindication to the planned vascular procedure.
Procedures that use this device
Frequently Asked Questions
What are the clinical indications for Cordis Catheter Sheath Introducer?
The device is indicated for use in central venous catheterization and other procedures requiring vascular access.
What outcomes have been reported in clinical studies?
Studies have reported successful catheterization and improved hemostasis, particularly in complex vascular procedures.
What complications have been reported?
Safety data indicate potential complications such as vascular spasm and pain, especially with larger sheath sizes.