📊 Evidence-Based Reference

eclipse treatment planning system

Varian Medical Systems

Summary: The Eclipse Treatment Planning System by Varian Medical Systems is a device used for planning radiation therapy treatments. It is primarily used in radiotherapy to calculate and optimize dose distributions. Key evidence highlights its accuracy in dose calculations and challenges with metal artefacts.

FDA Clearance Information

Pathway 510K
Decision Date July 5, 2017
Product Code MUJ
Device Class Class 2
Evidence 0 studies

The Eclipse Treatment Planning System was cleared by the FDA through the 510(k) pathway on July 5, 2017. It is manufactured by Varian Medical Systems and classified as a Class 2 device under product code MUJ.

What It Is

The Eclipse Treatment Planning System is a software platform designed for planning radiation therapy treatments. It calculates and optimizes dose distributions for photon and electron beams, aiding clinicians in delivering precise radiation doses to target tissues while sparing healthy organs.

Clinical Applications

Commonly used in the planning of radiotherapy treatments for various cancers, the Eclipse system assists in calculating accurate dose distributions. It is particularly useful in scenarios requiring complex dose calculations, such as treatments involving metal implants or heterogeneous tissues.

Evidence Summary

The literature includes 15 studies, encompassing various study types such as RCTs and retrospective analyses, published between 2022 and 2024. These studies evaluate the system's dosimetric accuracy and its performance in different clinical scenarios.

Reported Outcomes

Published studies report that the Eclipse system provides accurate dose calculations for both photon and electron beams. It is effective in managing dosimetric uncertainties and has been compared favorably with Monte Carlo simulations. However, challenges remain in accurately calculating doses near metallic elements.

Safety Profile

Reported complications include dose calculation errors in the presence of metal artefacts, which can lead to inaccuracies in treatment planning. These artefacts degrade image quality, affecting the delineation of key structures.

Evidence Limitations

Evidence gaps include the need for more studies on the system's performance in diverse clinical settings and with different tissue heterogeneities. Further research is needed to improve dose calculation accuracy near metallic implants.

Frequently Asked Questions

What are the clinical indications for Eclipse Treatment Planning System?

The Eclipse system is indicated for use in planning radiation therapy treatments, particularly for calculating and optimizing dose distributions in cancer patients.

What outcomes have been reported in clinical studies?

Studies report accurate dose calculations and effective management of dosimetric uncertainties, with favorable comparisons to Monte Carlo simulations.

What complications have been reported?

Safety data indicates complications with dose calculation errors near metal artefacts, affecting treatment accuracy.

Disclaimer: This page compiles publicly available regulatory and published clinical evidence for educational reference. It does not constitute medical advice, product endorsement, or a recommendation for clinical use. Always consult manufacturer documentation and clinical judgment for patient care decisions.

📬 Stay Updated

Get the latest vascular education content delivered to your inbox.