Edwards Esheath Optima Introducer Set

Edwards Lifesciences LLC

Ask about this device Compare similar devices

Summary: The Edwards eSheath Optima Introducer Set is a medical device used for vascular access during embolization procedures. It is typically utilized by interventional radiologists and cardiologists.

FDA Clearance Information

Pathway ? 510(k)
Number ? K252364 ↗
Decision Date ? August 29, 2025
Product Code ? DYB
Device Class ? Class 2
Evidence ? 0 studies

The Edwards eSheath Optima Introducer Set was cleared via the FDA 510k pathway on August 29, 2025. Manufactured by Edwards Lifesciences, it is a Class 2 device under product code DYB.

What It Is

The Edwards eSheath Optima Introducer Set is a vascular access device designed to facilitate the introduction of other medical devices into the vascular system. It features a sheath and dilator system that allows for smooth and controlled access, minimizing trauma to the vessel. This device is particularly useful in procedures requiring precise device placement within the vasculature.

FDA-Cleared Indications

  • Facilitates placement of embolization coils within the vasculature.

Clinical Applications

  • Vascular access for procedures that place embolization coils.
  • Access during endovascular treatment of selected aneurysms.
  • Access during embolization of selected vascular malformations.

Reported off-label uses

  • Use as an access sheath for delivery of other compatible embolization devices or interventional catheters may occur in clinical practice, but this should not be assumed to be FDA-cleared for this specific device.

Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.

Practical Considerations

  • Available sizes and usable lengths should be selected according to the target vessel, access route, anatomy, and embolization device requirements.
  • The sheath and dilator must be compatible with the intended catheter, coil-delivery system, guidewire, and other procedural equipment.
  • Use requires sterile technique, imaging guidance, and trained vascular-interventional personnel.
  • Potential access-related complications include bleeding, hematoma, vessel injury, thrombosis, infection, and contrast or embolic complications related to the underlying procedure.
  • MRI compatibility and conditions should be confirmed in the current Edwards labeling before MRI examination; do not assume the set is safe in an MR environment.

Procedures that use this device

Frequently Asked Questions

What is the Edwards eSheath Optima Introducer Set used for?

It is used for vascular access during embolization procedures, facilitating the introduction of embolization coils.

What specialties typically use this device?

Interventional radiologists and cardiologists typically use this device in procedures requiring vascular access.

What are the FDA-cleared indications?

The device is indicated for facilitating the placement of embolization coils in the vasculature for treating conditions like aneurysms.

Disclaimer: This page compiles publicly available regulatory and published clinical evidence for educational reference. It does not constitute medical advice, product endorsement, or a recommendation for clinical use. Always consult manufacturer documentation and clinical judgment for patient care decisions.