📋 FDA Reference

Lifeline Pacing Lead Model 467-01

Intermedics

Compare similar devices

Summary: The Lifeline Pacing Lead Model 467-01 is a cardiac pacing lead used in conjunction with pacemakers to manage arrhythmias. It is primarily used by cardiologists in hospital settings.

FDA Clearance Information

Pathway ? 510(k)
Number ? K781499 ↗
Decision Date ? February 1, 1979
Product Code ? DTB
Device Class ? Class 3
Evidence ? 0 studies

The Lifeline Pacing Lead Model 467-01 was cleared through the FDA 510k pathway on February 1, 1979. It is manufactured by Intermedics and classified as a Class III medical device.

What It Is

The Lifeline Pacing Lead Model 467-01 is a medical device used to deliver electrical impulses from a pacemaker to the heart muscle, ensuring proper heart rhythm. It is designed to be implanted into the heart and connected to a pacemaker device. This lead is crucial in managing patients with bradycardia or other arrhythmias, providing consistent pacing to maintain adequate heart rates.

FDA-Cleared Indications

  • Use with a permanent pacemaker system for cardiac pacing in patients with clinically indicated bradycardia or conduction disorders.
  • Placement in the heart to deliver pacing stimuli from an implanted pulse generator to the cardiac muscle.

Clinical Applications

  • Permanent pacemaker implantation for patients with symptomatic bradycardia.
  • Pacing support for conduction disorders such as heart block when a pacemaker is indicated.
  • Pacing in selected patients with sick sinus syndrome when permanent pacing is clinically indicated.
  • Connection of an implanted pacemaker pulse generator to the heart during a cardiac pacing procedure.

Practical Considerations

  • The lead must be compatible with the selected pacemaker pulse generator and the complete pacing system.
  • Correct intracardiac placement, electrical testing, and secure fixation are important for reliable sensing and pacing.
  • Available lead length and configuration should be matched to the patient's anatomy and the intended implantation approach.
  • MRI safety cannot be assumed for this older lead model; the complete implanted system should be evaluated against current manufacturer and MRI labeling before scanning.
  • Potential contraindications and complications include infection, bleeding, venous injury, lead displacement, perforation, pneumothorax, and loss of adequate sensing or capture.

Frequently Asked Questions

What is Lifeline Pacing Lead Model 467-01 used for?

It is used to deliver electrical impulses from a pacemaker to the heart to manage arrhythmias.

What specialties typically use this device?

Cardiologists and electrophysiologists typically use this device in cardiac procedures.

What are the FDA-cleared indications?

It is indicated for patients requiring cardiac pacing due to arrhythmias such as bradycardia.

Disclaimer: This page compiles publicly available regulatory and published clinical evidence for educational reference. It does not constitute medical advice, product endorsement, or a recommendation for clinical use. Always consult manufacturer documentation and clinical judgment for patient care decisions.