Medtronic Implantable Pacing Leads W Is-1 Conn
Medtronic Vascular
FDA Clearance Information
The Medtronic implantable pacing leads were cleared via the FDA 510(k) pathway on March 6, 1990. Manufactured by Medtronic Vascular, these devices are classified as Class III under product code DTB.
What It Is
FDA-Cleared Indications
- Use as part of an implantable cardiac pacing system when electrical stimulation of the heart is indicated.
- Use in patients requiring pacing support for bradycardia or cardiac conduction disorders.
- Use with compatible cardiac pulse generators through an IS-1 connector.
Clinical Applications
- Permanent pacemaker implantation for symptomatic bradycardia.
- Pacing support for atrioventricular block and other conduction disorders.
- Connection of a transvenous pacing lead to a compatible cardiac pulse generator.
- Delivery of electrical stimulation to the appropriate heart chamber as part of an implanted pacing system.
Reported off-label uses
- Use in selected congenital or inherited conduction disorders requiring long-term pacing.
- Use in some patients after cardiac surgery or ablation when persistent pacing support is needed.
Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.
Evidence Summary
Reported Outcomes
Safety Profile
Evidence Limitations
Practical Considerations
- The lead must be matched to a compatible generator and connector configuration; the IS-1 connector standard does not by itself establish compatibility with every generator.
- Lead length, diameter, fixation method, insulation, and electrode configuration vary by model and must be confirmed in the specific product labeling.
- Placement is usually performed through venous access with fluoroscopic guidance, followed by testing of sensing, pacing thresholds, and lead impedance.
- MRI eligibility depends on the exact lead model, generator, complete implanted system, and institutional MRI conditions. A lead should not be considered MRI-safe based only on the manufacturer name or IS-1 connector.
- Potential complications include lead dislodgment, fracture, insulation failure, loss of capture or sensing, infection, venous thrombosis, perforation, and complications related to venous access.
Frequently Asked Questions
What are the clinical indications for Medtronic implantable pacing leads?
The leads are indicated for use in patients requiring cardiac pacing, such as those with bradycardia or heart block.
What outcomes have been reported in clinical studies?
Studies report effective pacing but highlight issues with lead failures and device-related complications.
What complications have been reported?
Safety data indicate complications such as lead failures and device-device interference.