Model 483-02 Pacing Lead

Intermedics

Compare similar devices

Summary: The Model 483-02 pacing lead is a cardiac device used for pacing the heart. It is primarily utilized by cardiologists in patients requiring cardiac rhythm management.

FDA Clearance Information

Pathway ? 510(k)
Number ? K844269 ↗
Decision Date ? March 28, 1985
Product Code ? DTB
Device Class ? Class 3
Evidence ? 0 studies

The Model 483-02 pacing lead was cleared through the FDA 510(k) pathway on March 28, 1985. Manufactured by Intermedics, it is classified as a Class III device.

What It Is

The Model 483-02 pacing lead is a medical device designed to deliver electrical impulses to the heart to maintain an adequate heart rate. It is typically used in conjunction with a pacemaker. The lead is inserted into the heart via a vein and is crucial for patients with arrhythmias or heart block.

FDA-Cleared Indications

  • Cardiac pacing in patients who require electrical stimulation to maintain an adequate heart rate.
  • Use with a compatible pacemaker system for management of slow heart rhythms or heart block.

Clinical Applications

  • Permanent transvenous cardiac pacing when a pacemaker is clinically indicated.
  • Placement in the heart through a venous access route for delivery of pacing impulses.
  • Pacing support for patients with bradycardia or heart block, as specified by the compatible pacing system labeling.

Practical Considerations

  • Confirm compatibility with the intended pacemaker generator and the complete pacing system before implantation.
  • Select an appropriate lead length and configuration for the patient's anatomy and the planned cardiac chamber.
  • Placement requires fluoroscopic or other suitable imaging guidance and careful testing of electrical performance.
  • MRI safety cannot be determined from this historical device record alone; verify the complete system's current MRI labeling before scanning.
  • Assess for standard pacing-lead risks and contraindications, including infection, venous access problems, bleeding risk, lead dislodgement, perforation, and device malfunction.

Frequently Asked Questions

What is Model 483-02 pacing lead used for?

It is used for cardiac pacing in patients with arrhythmias or heart block to maintain a regular heart rate.

What specialties typically use this device?

Cardiologists, particularly those specializing in electrophysiology and cardiac surgery, commonly use this device.

What are the FDA-cleared indications?

The device is indicated for patients requiring cardiac pacing due to slow heart rhythms or heart block.

Disclaimer: This page compiles publicly available regulatory and published clinical evidence for educational reference. It does not constitute medical advice, product endorsement, or a recommendation for clinical use. Always consult manufacturer documentation and clinical judgment for patient care decisions.