📊 Evidence-Based Reference

monaco

Impac Medical Systems

Summary: Monaco is a treatment planning system used in radiotherapy. It is primarily used for creating high-quality radiotherapy treatment plans. Key evidence highlights its accuracy in dose calculation and optimization processes.

FDA Clearance Information

Pathway 510K
Decision Date July 7, 2015
Product Code MUJ
Device Class Class 2
Evidence 0 studies

Monaco was cleared by the FDA through the 510(k) pathway on July 7, 2015. It is manufactured by Impac Medical Systems and is classified as a Class 2 device.

What It Is

Monaco is a treatment planning system that utilizes Monte Carlo dose calculation for radiotherapy. It is designed to optimize treatment plans for various radiotherapy techniques, including 3D CRT, IMRT, VMAT, SRS, and SBRT.

Clinical Applications

Monaco is commonly used in clinical settings for planning radiotherapy treatments. It is particularly useful in scenarios requiring precise dose calculations and optimization, such as in cancer treatment.

Evidence Summary

The available literature includes 15 studies, primarily focusing on the optimization and accuracy of the Monaco treatment planning system. The studies range from 2018 to 2025, highlighting advancements in technology and application.

Reported Outcomes

Published studies report that Monaco provides high accuracy in dose distribution and optimization for radiotherapy treatments. The system's Monte Carlo algorithm is noted for its precision in aligning planned doses with actual irradiated doses.

Safety Profile

Reported complications include potential inaccuracies in dose calculation if transmission probability filters are not optimized. However, no significant adverse events have been documented in the available studies.

Evidence Limitations

The evidence is limited by a lack of large-scale clinical trials directly assessing patient outcomes. Further research is needed to evaluate long-term safety and efficacy in diverse patient populations.

Frequently Asked Questions

What are the clinical indications for Monaco?

Monaco is indicated for use in planning radiotherapy treatments, including 3D CRT, IMRT, VMAT, SRS, and SBRT.

What outcomes have been reported in clinical studies?

Studies report high accuracy in dose calculation and optimization, enhancing treatment precision.

What complications have been reported?

Safety data indicate potential inaccuracies in dose calculation if system parameters are not optimized, but no significant adverse events have been reported.

Disclaimer: This page compiles publicly available regulatory and published clinical evidence for educational reference. It does not constitute medical advice, product endorsement, or a recommendation for clinical use. Always consult manufacturer documentation and clinical judgment for patient care decisions.

📬 Stay Updated

Get the latest vascular education content delivered to your inbox.