Summary: The Philips M3001A Multi Measurement Server is a medical device used for monitoring vital signs such as ECG, SpO2, and blood pressure. It is commonly used by clinicians in hospital settings to provide continuous patient monitoring.

FDA Clearance Information

Pathway 510K
Decision Date May 4, 2009
Product Code DQA
Device Class Class 2
Evidence 419 studies

The Philips M3001A was cleared through the FDA 510(k) pathway on May 4, 2009. It is manufactured by Philips Medizin Systeme Boblingen and is classified as a Class 2 device under product code DQA.

What It Is

The Philips M3001A Multi Measurement Server is a versatile monitoring device that integrates with patient monitoring systems to measure and display vital signs including electrocardiogram (ECG), oxygen saturation (SpO2), and non-invasive blood pressure. It is designed to provide real-time data to healthcare providers, aiding in the assessment and management of patients' physiological status.

Clinical Applications

This device is commonly used in intensive care units, emergency departments, and during surgical procedures to monitor patients' vital signs continuously. It is particularly valuable in settings where rapid changes in a patient's condition can occur, such as in critical care or during anesthesia. The device is used across various specialties including cardiology, anesthesiology, and emergency medicine.

Indications for Use

The FDA indications for the Philips M3001A include its use in monitoring vital signs for patients requiring continuous observation. It is suitable for patients in critical care settings or those undergoing surgical procedures where real-time monitoring is essential.

Practical Considerations

The Philips M3001A is compatible with various Philips patient monitoring systems. It is important for clinicians to ensure proper connection and calibration to obtain accurate readings. The device is designed to be user-friendly, with intuitive interfaces for ease of use in fast-paced clinical environments.

Related Literature

The linked study discusses a voluntary device correction issued by Philips in 2006 regarding phantom pulse oximetry readings with their physiologic monitors using multi-measurement servers. The study highlights the importance of accurate readings in patient monitoring and the manufacturer's commitment to addressing potential device issues. Limitations include the lack of an available abstract and detailed findings.

Linked Studies (20)

PubMed • 2025

Onyx Liquid Embolic Agent: Basic Knowledge for Its Use in Interventional Neuroradiology.

Journal of neuroendovascular therapy

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Performance evaluation of quantitative hemoglobin A2 and fetal hemoglobin testing using commercially lyophilized vs. in-house whole blood controls in Chinese clinical laboratories: a 12-year analysis of National External Quality Assessment Data.

Clinical chemistry and laboratory medicine

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Clinical progress note: Haemophilus influenzae type b.

Journal of hospital medicine

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Pilot study of social media promotion of home-based self-testing for syphilis.

Sexually transmitted diseases

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Clinical development and performance of the First to Know Syphilis Self-Test for over-the-counter usage: a de novo rapid test for treponemal antibody.

Journal of clinical microbiology

View Source →
PubMed • 2025

Implementation of an Opt-Out and Rapid Point-of-Care Syphilis Testing Program for Pregnant Patients Presenting to the Emergency Department.

Sexually transmitted diseases

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Evaluation of Rapid Syphilis Testing Using the Syphilis Health Check in Florida, 2015-2016.

Florida public health review

View Source →
PubMed • 2025

Multiplex droplet digital PCR for the detection and quantitation of Streptococcus pneumoniae, Mycoplasma pneumoniae, and Haemophilus influenzae.

Frontiers in cellular and infection microbiology

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Palm Multidiagnostic of Mycoplasma pneumoniae, Chlamydia pneumoniae, Haemophilus influenzae, and Streptococcus pneumoniae Using One-Tube CRISPR/Cas12a.

Transboundary and emerging diseases

View Source →
PubMed • 2025

Tp40: a new potential prognostic and diagnostic marker for syphilis.

Microbiology spectrum

View Source →
PubMed • 2025

Serotonin sets up neutrophil extracellular traps to promote neuroendocrine prostate cancer metastasis in the liver.

The Journal of clinical investigation

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Application value of Philips Ingenuity TF PET/CT scanner imaging agent FAP in evaluating renal fibrosis.

Hellenic journal of nuclear medicine

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Message from Dr. Philippe T. Georgel, Guest Editor for the Marshall University Collection, Brad D. Smith, President of Marshall University, and Dr. Anivandan Mukherjee, Provost of Marshall University.

Biochemistry and cell biology = Biochimie et biologie cellulaire

View Source →
PubMed • 2025

Editorial - Philippe Ascher (1936-2022).

Neuroscience

View Source →
PubMed • 2025

Improved patient comfort and procedural efficiency using chlorhexidine-coated hydrophilic urethral catheters: a randomized controlled trial.

Journal of Yeungnam medical science

RCT View Source →
PubMed • 2025

pTx-Pulseq in hybrid sequences: Accessible and advanced hybrid open-source MRI sequences on Philips scanners.

Magnetic resonance in medicine

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Comparative connectomics of Drosophila descending and ascending neurons.

Nature

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Hydrophilic-coated sheaths for reducing radial artery spasm during transradial procedures: A systematic review and meta-analysis.

Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences

View Source →
PubMed • 2025

History of antineutrophil cytoplasmic autoantibodies : Milestones in rheumatology.

Zeitschrift fur Rheumatologie

View Source →
PubMed • 2025

A Hydrophilic Polyurethane Foam Containing Nigella sativa Oil as a Wound Dressing.

BioMed research international

RCT|prospective|retrospective|case Series|other View Source →

Frequently Asked Questions

What is the Philips M3001A Multi Measurement Server used for?

It is used for continuous monitoring of vital signs such as ECG, SpO2, and blood pressure in clinical settings.

What specialties typically use this device?

Specialties such as cardiology, anesthesiology, and emergency medicine commonly use this device.

What are the FDA-cleared indications?

The device is indicated for monitoring vital signs in patients requiring continuous observation, particularly in critical care and surgical settings.

Disclaimer: This page compiles publicly available regulatory and published clinical evidence for educational reference. It does not constitute medical advice, product endorsement, or a recommendation for clinical use. Always consult manufacturer documentation and clinical judgment for patient care decisions.

📬 Stay Updated

Get the latest vascular education content delivered to your inbox.