26 product lines across 5 device categories: Angiographic catheters, Guidewires, Thrombectomy devices, Microcatheters, Neuro aspiration catheters.
Angiographic Catheters
Used in: Uterine Artery Embolization (UAE), Internal Iliac Artery Embolization
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| Zoom 6F Insert Catheter, VRT Zoom 6F Insert Catheter, VRT, 137cm | Lumen/Inner Diameter: 0.04 in; Outer Diameter: 0.08 in; Catheter Length: 137 cm | 1 | Not stated |
| Zoom 6F Insert Catheter, VTK Zoom 6F Insert Catheter, VTK, 140cm | Catheter Length: 140 cm; Outer Diameter: 0.08 in; Lumen/Inner Diameter: 0.04 in | 1 | Not stated |
| Zoom 6F Insert Catheter, SIM Zoom 6F Insert Catheter, SIM, 143cm | Catheter Length: 143 cm; Outer Diameter: 0.08 in; Lumen/Inner Diameter: 0.04 in | 1 | Not stated |
Guidewires
Used in: Uterine Artery Embolization (UAE), Peripheral Balloon Angioplasty, Stroke Thrombectomy, Internal Iliac Artery Embolization
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| Ikon 14 Pro Guidewire Imperative Care Neurovascular Guidewire-Support, 0.014", 200cm | Outer Diameter: 0.01 in; Guidewire Length: 300 cm | 2 | MR Unsafe |
| Ikon 18 Pro Guidewire Imperative Care Neurovascular Guidewire-Support, 0.018", 260cm | Outer Diameter: 0.01 in; Guidewire Length: 300 cm | 2 | MR Unsafe |
| Ikon 14 Guidewire Imperative Care Neurovascular Guidewire-Standard, 0.014", 300cm | Outer Diameter: 0.01 in; Guidewire Length: 300 cm | 2 | MR Unsafe |
| Ikon 18 Guidewire Imperative Care Neurovascular Guidewire-Standard, 0.018", 200cm | Outer Diameter: 0.01 in; Guidewire Length: 300 cm | 1 | MR Unsafe |
| Ikon 24 Pro Guidewire Imperative Care Neurovascular Guidewire-Support, 0.024", 200cm | Outer Diameter: 0.01 in; Guidewire Length: 300 cm | 1 | MR Unsafe |
| Ikon 24 Guidewire Imperative Care Neurovascular Guidewire-Standard, 0.024", 200cm | Outer Diameter: 0.01 in; Guidewire Length: 300 cm | 1 | MR Unsafe |
Mechanical Thrombectomy Devices
Used in: DVT Mechanical Thrombectomy, Pulmonary Embolism Thrombectomy, Dialysis Graft and Fistula Thrombectomy
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| Prodigy Catheter 8F Prodigy™ Catheter Length: 90 cm Inner Diameter: 0.088 in Outer Diameter: 0.110 in (2.80 mm) | Catheter Length: 50–160 cm; Catheter Inner Diameter: 0.06–0.09 in; Outer Diameter: 0.07–0.11 in | 4 | Not stated |
| Symphony Catheter 24F Symphony™ Catheter w/ Dilator | Introducer Sheath Compatibility: 16–24 Fr; Catheter Working Length: 82–117 cm | 4 | Not stated |
| Prodigy Twist 8F Short Prodigy Twist™, 67 cm | Length: 67–177 cm | 4 | Not stated |
| Symphony ProHelix 16F Symphony™ ProHelix™ | Length: 102–139 cm | 2 | Not stated |
| Symphony Clot Container | — | 1 | Not stated |
| Symphony Advance Long Dilator 24F Symphony™ Advance™ Long Dilator | Introducer Sheath Compatibility: 24 Fr | 1 | Not stated |
| Hotshot Controller Prodigy Hotshot™ Controller | — | 1 | Not stated |
Microcatheters
Used in: Uterine Artery Embolization (UAE), Prostate Artery Embolization (PAE), Genicular Artery Embolization (GAE), Ovarian Vein Embolization, Varicocele Embolization, Transarterial Chemoembolization (TACE)
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| TracStar Large Distal Platform TracStar™ 6F 088 LDP, 90 cm | Lumen/Inner Diameter: 0.09 in; Outer Diameter: 0.11–0.11 in; Catheter Length: 90–110 cm | 5 | Not stated |
| TRX Long Sheath TRX™ 6F Long Sheath, 80 cm | Catheter Length: 80 cm; Outer Diameter: 0.11 in; Lumen/Inner Diameter: 0.09 in | 1 | Not stated |
Neurovascular Aspiration Catheters
Used in: Stroke Thrombectomy
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| ZOOM Reperfusion Catheter ZOOM 071 137 cm RC | Lumen/Inner Diameter: 0.04–0.07 in; Outer Diameter: 0.05–0.08 in; Catheter Length: 137–160 cm | 4 | Not stated |
| Zoom Catheter Zoom 071 137 cm RC | Lumen/Inner Diameter: 0.04–0.07 in; Outer Diameter: 0.05–0.08 in; Catheter Length: 137–160 cm | 4 | Not stated |
| Zoom RDL Radial Access System, 95cm Zoom RDL, 95cm with dilator | Lumen/Inner Diameter: 0.09 in; Outer Diameter: 0.11 in; Catheter Length: 95–110 cm | 4 | Not stated |
| Zoom 4S Catheter Zoom 4S Reperfusion Catheter, 125cm | Lumen/Inner Diameter: 0.05 in; Outer Diameter: 0.06 in; Catheter Length: 125–160 cm | 3 | Not stated |
| ZOOM 88 Large Distal Platform ZOOM™ 88 088 LDP, 100 cm | Lumen/Inner Diameter: 0.09 in; Outer Diameter: 0.11 in; Catheter Length: 100–110 cm | 2 | Not stated |
| Zoom 7X Catheter Zoom 7X Catheter, 137cm | Lumen/Inner Diameter: 0.07 in; Outer Diameter: 0.08 in; Catheter Length: 137 cm | 1 | Not stated |
| ZOOM 88-T Large Distal Platform ZOOM™ 88-T 6F 088 LDP, 110 cm | Lumen/Inner Diameter: 0.09 in; Outer Diameter: 0.11 in; Catheter Length: 110 cm | 1 | Not stated |
| Zoom 88 Large Distal Platform Support Zoom 88 088 LDP Support, 100 cm | Lumen/Inner Diameter: 0.09 in; Outer Diameter: 0.11 in; Catheter Length: 100 cm | 1 | Not stated |
Sales representatives
No representatives listed yet. Manufacturers can add their reps by territory.
FDA clearances and approvals
Product lines, models and sizes are compiled from the FDA Global Unique Device Identification Database (GUDID) and FDA clearance records. Descriptions marked "Provided by the manufacturer" come from the company and are reviewed before publishing.