Natec Medical Ltd

14 product lines across 1 device categories: Angioplasty balloons.

From natec-medical.com, checked October 2026.

Search Natec Medical Ltd PTA balloons

Is this your company? Claim this page to add product descriptions, indications, sizes and your sales reps by territory.

About Natec Medical Ltd

Natec Medical Ltd hasn't added a company description yet.

Peripheral Angioplasty Balloons

Used in: DVT Mechanical Thrombectomy, Venous Stenting (Iliac and Central Veins), Peripheral Balloon Angioplasty, Peripheral Artery Stenting, Peripheral Atherectomy, Fistulogram with Angioplasty

ProductSizes (FDA GUDID)ModelsMRI
Victory 0.035" PTA OTW Catheter
Victory 0.035" PTA OTW Catheter, 4.00 X 150 MM/ Shaft length 150 CM
Balloon Diameter: 3–12 mm; Balloon Length: 20–200 mm168Not stated
Ebony HP PTA OTW 0.035" Catheter
Ebony HP PTA OTW 0.035" Catheter, 5.00 X 80 MM /Shaft Length 75 CM
Balloon Diameter: 3–12 mm; Balloon Length: 20–200 mm164Not stated
Victory HP PTA 0.035" OTW Catheter
Victory HP PTA 0.035" OTW Catheter, 3.00 X 60 MM/ Shaft length 40 CM
Balloon Diameter: 3–12 mm; Balloon Length: 20–200 mm164Not stated
Ebony 0.014" PTA Rx Catheter
Ebony 0.014" PTA Rx Catheter, 5.00 X 150 MM
Balloon Length: 10–200 mm; Balloon Diameter: 1.5–8 mm144Not stated
Victory 0.018" PTA OTW Catheter
Victory 0.018" PTA OTW Catheter, 3.50 X 40 MM/ Shaft length 150 CM
Balloon Diameter: 2–7 mm; Balloon Length: 40–200 mm114Not stated
Amethyst HP PTA OTW 0.035" catheter
Amethyst HP PTA OTW 0.035" catheter, 8.00 X 100 MM /shaft length 75 CM
Balloon Length: 20–100 mm; Balloon Diameter: 4–12 mm105Not stated
USE 0.018" PTA OTW Catheter
USE® 0.018" PTA OTW Catheter, 2.50x80mm /Shaft length 150cm
Outer Diameter: 2–7 mm; Length: 40–200 mm100Not stated
USE 0.035" PTA OTW Catheter
USE® 0.035" PTA OTW Catheter, 7.00x60mm /Shaft length 80cm
Length: 20–200 mm; Outer Diameter: 5–10 mm80Not stated
USE 0.014" PTA OTW Catheter
USE® 0.014" PTA OTW Catheter, 2.50x200mm /Shaft length 250cm
Length: 20–200 mm; Outer Diameter: 1.5–4 mm72Not stated
Victory 0.014" PTA OTW Catheter
Victory 0.014" PTA OTW Catheter, 2.00 X 100 MM/ Shaft length 150 CM
Balloon Diameter: 1.5–4 mm; Balloon Length: 20–200 mm72Not stated
USE 0.014" PTA RX Catheter
USE® 0.014" PTA RX Catheter, 3.00x100mm /Shaft length 150cm
Length: 20–200 mm; Outer Diameter: 2–4 mm40Not stated
Ebony 0.018" PTA OTW Catheter
Ebony 0.018" PTA OTW Catheter, 3.50 x 200mm/ Shaft length 150cm
Balloon Diameter: 2–6 mm; Balloon Length: 40–200 mm29Not stated
Ebony 0.014" PTA OTW Catheter
Ebony 0.014" PTA OTW Catheter, 3.00 x 60mm/ Shaft length 150cm
Balloon Diameter: 2–4 mm; Balloon Length: 40–200 mm18Not stated
Ebony 0.035" PTA OTW Catheter
Ebony 0.035" PTA OTW Catheter, 5.00 x 40mm/ Shaft length 80cm
Balloon Diameter: 5–6 mm; Balloon Length: 40–200 mm10Not stated

Sales representatives

Natec Medical Ltd has not listed representatives here yet. Contact the company directly:

From natec-medical.com, checked October 2026.

Outside their markets or no reply? Send us a request.

Work for Natec Medical Ltd? Add a rep and the areas they cover:

Product lines, models and sizes are compiled from the FDA Global Unique Device Identification Database (GUDID) and FDA clearance records. Descriptions marked "Provided by the manufacturer" come from the company and are reviewed before publishing.

📬 The IR Device Brief

One email a month: new FDA clearances, recalls and device pages in vascular & interventional radiology.

We'll email you a link to confirm. Unsubscribe any time.

Suggest edits

For manufacturers and their teams. Each field shows what the page says now: add, remove or rewrite anything, and leave the rest as is. LA Vascular reviews every change before it goes live.