Natec Medical Ltd
14 product lines across 1 device categories: Angioplasty balloons.
Is this your company? Claim this page to add product descriptions, indications, sizes and your sales reps by territory.
Peripheral Angioplasty Balloons
Used in: DVT Mechanical Thrombectomy, Venous Stenting (Iliac and Central Veins), Peripheral Balloon Angioplasty, Peripheral Artery Stenting, Peripheral Atherectomy, Fistulogram with Angioplasty
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| Victory 0.035" PTA OTW Catheter Victory 0.035" PTA OTW Catheter, 4.00 X 150 MM/ Shaft length 150 CM | Balloon Diameter: 3–12 mm; Balloon Length: 20–200 mm | 168 | Not stated |
| Ebony HP PTA OTW 0.035" Catheter Ebony HP PTA OTW 0.035" Catheter, 5.00 X 80 MM /Shaft Length 75 CM | Balloon Diameter: 3–12 mm; Balloon Length: 20–200 mm | 164 | Not stated |
| Victory HP PTA 0.035" OTW Catheter Victory HP PTA 0.035" OTW Catheter, 3.00 X 60 MM/ Shaft length 40 CM | Balloon Diameter: 3–12 mm; Balloon Length: 20–200 mm | 164 | Not stated |
| Ebony 0.014" PTA Rx Catheter Ebony 0.014" PTA Rx Catheter, 5.00 X 150 MM | Balloon Length: 10–200 mm; Balloon Diameter: 1.5–8 mm | 144 | Not stated |
| Victory 0.018" PTA OTW Catheter Victory 0.018" PTA OTW Catheter, 3.50 X 40 MM/ Shaft length 150 CM | Balloon Diameter: 2–7 mm; Balloon Length: 40–200 mm | 114 | Not stated |
| Amethyst HP PTA OTW 0.035" catheter Amethyst HP PTA OTW 0.035" catheter, 8.00 X 100 MM /shaft length 75 CM | Balloon Length: 20–100 mm; Balloon Diameter: 4–12 mm | 105 | Not stated |
| USE 0.018" PTA OTW Catheter USE® 0.018" PTA OTW Catheter, 2.50x80mm /Shaft length 150cm | Outer Diameter: 2–7 mm; Length: 40–200 mm | 100 | Not stated |
| USE 0.035" PTA OTW Catheter USE® 0.035" PTA OTW Catheter, 7.00x60mm /Shaft length 80cm | Length: 20–200 mm; Outer Diameter: 5–10 mm | 80 | Not stated |
| USE 0.014" PTA OTW Catheter USE® 0.014" PTA OTW Catheter, 2.50x200mm /Shaft length 250cm | Length: 20–200 mm; Outer Diameter: 1.5–4 mm | 72 | Not stated |
| Victory 0.014" PTA OTW Catheter Victory 0.014" PTA OTW Catheter, 2.00 X 100 MM/ Shaft length 150 CM | Balloon Diameter: 1.5–4 mm; Balloon Length: 20–200 mm | 72 | Not stated |
| USE 0.014" PTA RX Catheter USE® 0.014" PTA RX Catheter, 3.00x100mm /Shaft length 150cm | Length: 20–200 mm; Outer Diameter: 2–4 mm | 40 | Not stated |
| Ebony 0.018" PTA OTW Catheter Ebony 0.018" PTA OTW Catheter, 3.50 x 200mm/ Shaft length 150cm | Balloon Diameter: 2–6 mm; Balloon Length: 40–200 mm | 29 | Not stated |
| Ebony 0.014" PTA OTW Catheter Ebony 0.014" PTA OTW Catheter, 3.00 x 60mm/ Shaft length 150cm | Balloon Diameter: 2–4 mm; Balloon Length: 40–200 mm | 18 | Not stated |
| Ebony 0.035" PTA OTW Catheter Ebony 0.035" PTA OTW Catheter, 5.00 x 40mm/ Shaft length 80cm | Balloon Diameter: 5–6 mm; Balloon Length: 40–200 mm | 10 | Not stated |
Sales representatives
No representatives listed yet. Manufacturers can add their reps by territory.
Product lines, models and sizes are compiled from the FDA Global Unique Device Identification Database (GUDID) and FDA clearance records. Descriptions marked "Provided by the manufacturer" come from the company and are reviewed before publishing.