Bard Utraverse Small Vessel PTA Balloon Dilatation Catheter
FDA Clearance Information
The Bard Utraverse Small Vessel PTA Balloon was cleared through the FDA 510(k) pathway on February 13, 2001. Manufactured by C.R. Bard, it is classified as a Class 2 medical device under product code DQY.
What It Is
FDA-Cleared Indications
- Use in percutaneous transluminal angioplasty of peripheral small vessels.
- Dilation of stenotic or obstructed peripheral arteries to improve blood flow.
- Use during endovascular treatment of peripheral vascular disease when balloon angioplasty is indicated.
Clinical Applications
- Balloon angioplasty of narrowed small peripheral arteries.
- Endovascular treatment of peripheral arterial stenosis or occlusion.
- Treatment of lower-extremity peripheral artery disease when the target vessel is appropriate for the catheter's size range.
- Adjunctive balloon dilation during a peripheral vascular intervention.
Reported off-label uses
- Use in selected venous angioplasty procedures, such as treatment of focal venous stenosis, may occur in clinical practice but is not necessarily covered by the device's small-vessel arterial labeling.
- Use in vessels or clinical situations outside the labeled size, anatomy, or indication may be considered off-label and should be based on clinician judgment, available evidence, and institutional policy.
Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.
Practical Considerations
- Select the balloon diameter and length to match the target vessel and follow the product labeling for rated burst pressure and inflation technique.
- The catheter is used over a compatible guidewire under fluoroscopic or other appropriate imaging guidance, generally through percutaneous arterial access.
- Do not use if the device is damaged, expired, or incompatible with the planned guidewire, sheath, contrast medium, or inflation system.
- MRI safety depends on the specific catheter and whether any device components remain in the patient; confirm the current labeling before MRI.
- Potential complications include vessel dissection, perforation, thrombosis, embolization, bleeding, restenosis, and allergic or kidney-related complications from contrast.
Related Literature
Procedures that use this device
Frequently Asked Questions
What is the Bard Utraverse Small Vessel PTA Balloon used for?
It is used for percutaneous transluminal angioplasty to open narrowed or blocked small vessels, particularly in patients with peripheral artery disease.
What specialties typically use this device?
Interventional radiologists and vascular surgeons commonly use this device in endovascular procedures.
What are the FDA-cleared indications?
The device is indicated for use in percutaneous transluminal angioplasty to treat narrowed or blocked small vessels in patients with peripheral artery disease.