📊 Evidence-Based Reference

Gore Excluder Aaa Endoprosthesis

W. L. Gore & Associates, Inc.

Product: GORE EXCLUDER AAA Endoprosthesis — all models and sizes

Contact a rep Compare similar devices

Summary: The Gore Excluder AAA Endoprosthesis is a device used for endovascular aneurysm repair. It is primarily used to treat infrarenal aortic aneurysms. Key evidence highlights its long-term performance and safety profile.

FDA Clearance Information

Pathway ? PMA
Number ? P020004 ↗
Decision Date ? September 21, 2006
Product Code ? MIH System, Endovascular Graft, Aortic Aneurysm Treatment
Device Class ? Class 3
Evidence ? 40 studies

The Gore Excluder AAA Endoprosthesis was cleared by the FDA via the PMA pathway on September 21, 2006. It is manufactured by W.L. Gore & Associates and is classified as a Class 3 medical device.

What It Is

The Gore Excluder AAA Endoprosthesis is an endovascular stent graft designed to treat abdominal aortic aneurysms. It functions by excluding the aneurysm from blood flow, thereby reducing the risk of rupture. It is intended for use in patients with infrarenal aortic aneurysms.

FDA-Cleared Indications

  • Endovascular treatment of abdominal aortic aneurysms using an endovascular graft system.
  • Use in patients whose aortic and iliac anatomy meets the device-specific requirements in the current instructions for use.
  • The 2006 FDA record identifies a change to an acceptance criterion for a component used in manufacturing the device; it does not provide a new clinical indication in the supplied FDA text.

Clinical Applications

  • Endovascular aneurysm repair of selected infrarenal abdominal aortic aneurysms.
  • Treatment of abdominal aortic aneurysms in patients whose proximal aortic neck, aneurysm morphology, and iliac access vessels meet the device labeling.
  • Use as a modular endovascular graft system with a main body and iliac limb components to exclude the aneurysm from circulation.
  • Repair performed through catheter access, typically through the common femoral arteries, when anatomy is suitable for the labeled device configuration.

Reported off-label uses

  • Use outside the device's labeled anatomic requirements, including selected anatomies with inadequate proximal neck or iliac landing zones, has been described in clinical practice but is off-label and may carry additional risks.
  • Selected emergency or complex aortic applications outside the original abdominal aortic aneurysm labeling have been reported for endovascular grafts, but require case-specific specialist judgment and are not established indications for this device record.

Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.

Evidence Summary

The available literature includes 14 studies, encompassing randomized controlled trials, prospective and retrospective studies, and case series. These studies span from 2022 to 2026, providing a comprehensive overview of the device's performance.

Reported Outcomes

Published studies report that the Gore Excluder AAA Endoprosthesis demonstrates favorable long-term outcomes in terms of aneurysm exclusion and patient survival. The device has shown efficacy in reducing aneurysm-related mortality and maintaining patency over extended follow-up periods.

Safety Profile

Reported complications include inflammatory responses and potential for serious adverse events, particularly in older patients. Some studies noted the occurrence of inflammatory aneurysms related to elevated serum levels of Immunoglobulin G4 post-procedure.

Evidence Limitations

Evidence gaps include a need for more diverse patient populations and longer follow-up periods to better understand the device's performance across different demographics. Further research is needed to explore the relationship between inflammatory responses and the device.

Practical Considerations

  • The device is modular and available in multiple diameters and lengths; component selection must match the patient's aortic neck, aneurysm, and iliac artery measurements.
  • Preprocedure CT angiography is generally used to assess landing zones, vessel diameter, tortuosity, calcification, thrombus, and femoral or iliac access.
  • Important contraindications or limitations may include anatomy outside the instructions for use, unsuitable landing zones, inadequate iliac access, active infection, or inability to tolerate contrast, anticoagulation, or the procedure.
  • Follow-up imaging is required to monitor for endoleak, graft migration, limb obstruction, aneurysm enlargement, or other late device-related complications.
  • MRI safety and scanning conditions depend on the exact GORE EXCLUDER component and labeling for the implanted configuration; the current device-specific MRI conditions should be checked before scanning.

Linked Studies (20)

PubMed • 2026

Long Term Real World Performance of the Gore Excluder AAA Endoprosthesis Featuring the C3 Delivery System: Ten Year Results from the European C3 Module of the GREAT Registry.

European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Mid-Term Outcomes of EVAR in Hostile Neck Anatomy: Impact of Graft Adaptability on Type III Endoleak, Aortic Remodeling, and Distal Sealing.

Journal of clinical medicine

View Source →
PubMed • 2025

Conformable Endovascular Aneurysm Repair (EVAR) Stability in Hostile Neck Abdominal Aortic Aneurysms: A Single-Center Experience.

Cureus

View Source →
PubMed • 2025

Early results from the pivotal trial substudy of the GORE EXCLUDER conformable endoprosthesis in angulated necks.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

British Society of Endovascular Therapy ConformabLe EndoVascular Aneurysm Repair Registry: An Analysis of Aortic Neck Coverage of the GORE® EXCLUDER® Conformable AAA Endoprosthesis With ACTIVE CONTROL System.

Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Inflammatory Aneurysm of the Common Iliac Artery With Elevated Serum Levels of Immunoglobulin G4 Manifesting After Endovascular Aneurysm Repair: A Case Report.

Cureus

View Source →
PubMed • 2025

One-year outcomes from the pivotal trial of a four-branch off-the-shelf solution to treat pararenal and extent IV thoracoabdominal aortic aneurysms.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Wire wrap involving the celiac and superior mesenteric artery portals of the GORE EXCLUDER thoracoabdominal branch endoprosthesis: A multi-center case series.

Journal of vascular surgery cases and innovative techniques

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Total transfemoral approach for Gore Excluder thoracoabdominal branch endoprosthesis (TAMBE), external tour de graft technique.

Journal of vascular surgery cases and innovative techniques

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Component use of the GORE TAG thoracic branch endoprosthesis, GORE TAG conformable thoracic stent graft, GORE EXCLUDER thoracoabdominal branch endoprosthesis, and GORE EXCLUDER iliac branch endoprosthesis for the treatment of an extent II thoracoabdominal aortic aneurysm.

Journal of vascular surgery cases and innovative techniques

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2024

Three-year outcomes of a US pivotal trial substudy for conformable endoprosthesis in ≥10 mm nonangulated neck anatomy.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2023

Long-term Outcomes of the Endurant and Excluder Stent Grafts for Endovascular Aneurysm Repair in a Japanese Cohort.

Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2023

Use of real-world data and clinical registries to identify new uses of existing vascular endografts: combined use of GORE EXCLUDER Iliac Branch Endoprosthesis and GORE VIABAHN VBX Balloon Expandable Endoprosthesis.

BMJ surgery, interventions, & health technologies

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2023

Emergent endovascular treatment options for thoracoabdominal aortic aneurysm.

Seminars in vascular surgery

View Source →
PubMed • 2023

Technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the Gore Excluder conformable device in angulated and short landing zones.

Journal of vascular surgery cases and innovative techniques

Case Series View Source →
PubMed • 2022

One-year results of the GORE EXCLUDER Conformable AAA Endoprosthesis system in the United States regulatory trial.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2022

Excluder Stent Graft-Related Outcomes in Patients with Aortic Neck Anatomy Outside of Instructions For Use (IFU) within the Global Registry for Endovascular Aortic Treatment (GREAT): Mid-term Follow-Up Results.

Annals of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2022

Protocol for GUo's renovisceral Artery reconstruction-1: a prospective, multicentre, single-arm clinical trial to evaluate the safety and efficacy of a multibRANched sTEnt graft systEm for thoracoabdominal aortic aneurysm (GUARANTEE study).

BMJ open

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2022

Outcomes of Gore iliac branch endoprosthesis with internal iliac component versus Gore Viabahn VBX.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2021

Comparison of anatomic feasibility of three different multibranched off-the-shelf stent-grafts designed for thoracoabdominal aortic aneurysms.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →

Frequently Asked Questions

What are the clinical indications for Gore Excluder AAA Endoprosthesis?

The device is indicated for the endovascular repair of infrarenal abdominal aortic aneurysms in patients who meet specific anatomical criteria.

What outcomes have been reported in clinical studies?

Clinical studies have reported favorable long-term outcomes, including reduced aneurysm-related mortality and sustained device patency.

What complications have been reported?

Safety data indicate complications such as inflammatory responses and serious adverse events, particularly in older patients.

Disclaimer: This page compiles publicly available regulatory and published clinical evidence for educational reference. It does not constitute medical advice, product endorsement, or a recommendation for clinical use. Always consult manufacturer documentation and clinical judgment for patient care decisions.

📬 The IR Device Brief

One email a month: new FDA clearances, recalls and device pages in vascular & interventional radiology.

We'll email you a link to confirm. Unsubscribe any time.

Suggest edits

For manufacturers and their teams. Each field shows what the page says now: add, remove or rewrite anything, and leave the rest as is. LA Vascular reviews every change before it goes live.

About you