📋 FDA Reference

Infusion Catheter W Side Holes

Target Therapeutics

Compare similar devices

Summary: The infusion catheter with side holes by Target Therapeutics is a medical device used to deliver fluids directly into blood vessels. It is primarily used by interventional radiologists and vascular surgeons in various clinical settings.

FDA Clearance Information

Pathway ? 510(k)
Number ? K854000 ↗
Decision Date ? November 5, 1985
Product Code ? DQY Catheter, Percutaneous
Device Class ? Class 2
Evidence ? 0 studies

This device was cleared through the FDA 510(k) pathway on November 5, 1985. Manufactured by Target Therapeutics, it is classified as a Class 2 medical device under product code DQY.

What It Is

The infusion catheter with side holes is designed to deliver therapeutic agents directly into the vascular system. The side holes allow for even distribution of fluids, which can include medications, contrast agents, or other therapeutic substances. This design helps in achieving targeted delivery, minimizing systemic exposure and potential side effects.

FDA-Cleared Indications

  • Delivery of fluids directly into the vascular system.
  • Infusion of medications, contrast agents, or other therapeutic fluids through a percutaneously placed vascular catheter.

Clinical Applications

  • Controlled vascular infusion during interventional radiology procedures.
  • Delivery of contrast material during angiographic imaging.
  • Administration of therapeutic fluids into a selected blood vessel when percutaneous vascular access is appropriate.
  • Infusion procedures performed in hospital or procedural settings under imaging guidance.

Reported off-label uses

  • Targeted intra-arterial chemotherapy or other regional drug delivery when the specific use is not included in the device labeling.
  • Catheter-directed thrombolytic infusion for selected vascular thrombosis cases when the catheter and treatment plan are not specifically covered by the labeling.

Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.

Practical Considerations

  • The appropriate catheter diameter, length, tip configuration, and number or location of side holes depend on the access route, target vessel, infusion requirements, and vessel size.
  • Compatibility with the introducer sheath, guidewire, injection system, contrast agent, medication, and other vascular devices should be confirmed before use.
  • Insertion and positioning are typically performed with fluoroscopic or other imaging guidance by trained clinicians; incorrect placement can cause ineffective delivery, vessel injury, bleeding, or embolization.
  • MRI safety cannot be determined from the FDA product code alone. The exact catheter model and labeling should be checked for MR Safe, MR Conditional, or MR Unsafe status before MRI.
  • Potential complications include infection, bleeding, thrombosis, vessel perforation or dissection, catheter damage, and unintended infusion into an incorrect vessel. Contraindications and precautions depend on the patient's vascular access site, coagulation status, allergy history, and the intended infusate.

Procedures that use this device

Frequently Asked Questions

What is the infusion catheter with side holes used for?

It is used for delivering therapeutic agents directly into blood vessels, often in procedures requiring precise and localized treatment.

What specialties typically use this device?

Interventional radiologists and vascular surgeons primarily use this device in various vascular interventions.

What are the FDA-cleared indications?

The catheter is indicated for the delivery of fluids directly into the vascular system for patients needing targeted vascular treatment.

Disclaimer: This page compiles publicly available regulatory and published clinical evidence for educational reference. It does not constitute medical advice, product endorsement, or a recommendation for clinical use. Always consult manufacturer documentation and clinical judgment for patient care decisions.

📬 The IR Device Brief

One email a month: new FDA clearances, recalls and device pages in vascular & interventional radiology.

We'll email you a link to confirm. Unsubscribe any time.

Suggest edits

For manufacturers and their teams. Each field shows what the page says now: add, remove or rewrite anything, and leave the rest as is. LA Vascular reviews every change before it goes live.

About you