📊 Evidence-Based Reference

Oria Zenith

Ortho Tec

Compare similar devices

Summary: The Oria Zenith is an aortic stent-graft designed for endovascular repair of thoracoabdominal aortic aneurysms. Key evidence highlights its efficacy in complex aortic repairs with some reported complications.

FDA Clearance Information

Pathway ? 510(k)
Number ? K030500 ↗
Decision Date ? March 20, 2003
Product Code ? KWQ
Device Class ? Class 2
Evidence ? 35 studies

The Oria Zenith was cleared by the FDA through the 510(k) pathway on March 20, 2003. It is manufactured by Ortho Tec and classified as a Class 2 medical device.

What It Is

The Oria Zenith is an aortic stent-graft used in endovascular procedures to treat thoracoabdominal aortic aneurysms. It is designed to provide a minimally invasive option for repairing complex aortic aneurysms.

FDA-Cleared Indications

  • Endovascular repair of thoracoabdominal aortic aneurysms, as described in the available FDA summary.

Clinical Applications

  • Endovascular placement across a thoracoabdominal aortic aneurysm to exclude the aneurysm from blood flow.
  • Treatment of selected complex thoracoabdominal aortic aneurysms when anatomy is suitable for stent-graft repair.
  • Use as a minimally invasive alternative to open surgical aneurysm repair in appropriately selected patients.

Reported off-label uses

  • Use in selected aneurysms or dissections outside the specific labeled thoracoabdominal indication has been described for some aortic stent-graft systems, but this should not be assumed to be cleared for the Oria Zenith.

Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.

Evidence Summary

The available literature includes a mix of randomized controlled trials, prospective and retrospective studies, and case series, with a total of 8 studies published between 2023 and 2025.

Reported Outcomes

Published studies report that the Oria Zenith is effective in the endovascular repair of thoracoabdominal aortic aneurysms, with successful outcomes in complex cases. The device has shown promise in reducing procedural risks associated with open surgery.

Safety Profile

Reported complications include device-related adverse events such as distal stent-graft induced new entry (dSINE) and issues related to the structural integrity of the aortic wall. These complications highlight the need for careful patient selection and monitoring.

Evidence Limitations

The evidence is limited by the small number of studies and the variability in study design. Further research is needed to establish long-term outcomes and to refine patient selection criteria.

Practical Considerations

  • The available record does not provide the device's full size range, delivery-system specifications, or detailed anatomic requirements; clinicians should consult the official labeling.
  • Treatment requires suitable aortic landing zones, access vessels, and branch-vessel anatomy, which are assessed with contrast-enhanced CT angiography or another appropriate imaging study.
  • Placement is performed under fluoroscopic imaging, usually through femoral or iliac arterial access, with anesthesia or sedation selected according to the procedure and patient.
  • MRI safety and conditional scanning requirements must be confirmed from the device labeling; do not assume the graft is safe under all MRI conditions.
  • Potential issues include endoleak, graft migration or obstruction, branch-vessel compromise, access-site injury, renal injury from contrast, and the need for lifelong imaging surveillance.

Linked Studies (20)

PubMed • 2025

Outcomes of patients with acute complicated type B aortic dissections repaired with the Zenith dissection endovascular system compared to aortic stent graft.

Vascular

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Gingival zenith level, position, and symmetry: A systematic review and meta-analysis.

The Journal of prosthetic dentistry

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2024

Expert-Based Narrative Review on Contemporary Use of an Off-The-Shelf Multibranched Endograft for Endovascular Treatment of Thoracoabdominal Aortic Aneurysms: Device Design, Anatomical Suitability, Technical Tips, Perioperative Care, Clinical Applications, and Real-World Experience.

Annals of vascular surgery

View Source →
PubMed • 2024

Exploring atmospheric optical turbulence: observations across zenith angles.

Applied optics

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2024

Cook Zenith Alpha Endograft: A Protocol to Minimise Limb Graft Occlusion.

European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2024

Gingival Zenith Correction by Laser Gingivectomy.

Cureus

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2023

A Retrospective Evaluation of Intra-Prosthetic Thrombus Formation After Endovascular Aortic Repair in Cook Zenith Alpha and Medtronic Endurant II Patients.

European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery

Retrospective View Source →
PubMed • 2023

Emergent endovascular treatment options for thoracoabdominal aortic aneurysm.

Seminars in vascular surgery

View Source →
PubMed • 2023

Commentary: Data zenith.

The Journal of thoracic and cardiovascular surgery

View Source →
PubMed • 2022

Placement of a Zenith® Dissection Endovascular System in the Descending Thoracic Aorta Can Hamper Further Surgical Aortic Operations.

EJVES vascular forum

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2022

Midterm outcomes of aneurysm repair with the Cook Zenith Alpha abdominal endovascular graft.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2021

Comparison of anatomic feasibility of three different multibranched off-the-shelf stent-grafts designed for thoracoabdominal aortic aneurysms.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2021

New Technical Approach to Overcome Anatomical Challenges During Branched Endovascular Aortic Repair with off-the-Shelf Multibranched Stent-Grafts: Are We Sequentially and Progressively Scraping the Sky? : Commentary on "Sequential catheterization and progressive deployment of the Zenith tBranchTM device for branched endovascular aortic aneurysm repair".

Cardiovascular and interventional radiology

View Source →
PubMed • 2021

Kinematic Zenith Tropospheric Delay Estimation with GNSS PPP in Mountainous Areas.

Sensors (Basel, Switzerland)

View Source →
PubMed • 2020

Five-year results from the Study of Thoracic Aortic Type B Dissection Using Endoluminal Repair (STABLE I) study of endovascular treatment of complicated type B aortic dissection using a composite device design.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2020

Physician-Modified Endograft With Double Inner Branches for Urgent Repair of Supraceliac Para-Anastomotic Pseudoaneurysm.

Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2019

Device profile of the Zenith Dissection Endovascular System for aortic dissection.

Expert review of medical devices

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2016

Thoracic endovascular aortic repair for complicated chronic type B aortic dissection in a patient on hemodialysis with recurrent ischemic colitis.

Surgical case reports

Case Series View Source →
PubMed • 2015

Surgeon custom-made iliac branch device to salvage hypogastric artery during endovascular aneurysm repair.

Journal of Korean medical science

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2014

Experience of the Zenith Dissection Endovascular System in the emergency setting of malperfusion in acute type B dissections.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →

Frequently Asked Questions

What are the clinical indications for Oria Zenith?

The Oria Zenith is indicated for the endovascular repair of thoracoabdominal aortic aneurysms, particularly in patients where open surgery is not an option.

What outcomes have been reported in clinical studies?

Clinical studies have reported successful repair of complex aortic aneurysms with the Oria Zenith, demonstrating its efficacy in reducing procedural risks.

What complications have been reported?

Safety data from evidence indicate complications such as distal stent-graft induced new entry (dSINE) and issues with aortic wall integrity.

Disclaimer: This page compiles publicly available regulatory and published clinical evidence for educational reference. It does not constitute medical advice, product endorsement, or a recommendation for clinical use. Always consult manufacturer documentation and clinical judgment for patient care decisions.