Reverse Medical Micro Vascular Plug System
Product: MVP — all models and sizes
FDA Clearance Information
The Reverse Medical Micro Vascular Plug System was cleared by the FDA through the 510(k) pathway on June 18, 2014. It is manufactured by Reverse Medical and is classified as a Class 2 device.
What It Is
FDA-Cleared Indications
- Occlusion of selected blood vessels by endovascular embolization.
- Treatment of arterioportal fistulas.
- Use in neurovascular and other vascular applications where controlled vessel occlusion is indicated.
Clinical Applications
- Embolization of arterioportal fistulas.
- Targeted occlusion of vessels involved in neurovascular pathologies.
- Endovascular treatment of selected vascular anomalies requiring vessel occlusion.
Reported off-label uses
- Embolization of selected visceral artery aneurysms or pseudoaneurysms.
- Internal iliac artery embolization for selected pelvic bleeding or preoperative indications.
- Ovarian vein embolization for pelvic venous disorders.
- Varicocele embolization.
Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.
Evidence Summary
Reported Outcomes
Safety Profile
Evidence Limitations
Practical Considerations
- The plug is delivered through a compatible catheter, with size selection based on the target vessel diameter, anatomy and desired degree of occlusion.
- The procedure is performed under fluoroscopic or other appropriate imaging guidance, usually through percutaneous vascular access.
- Users should confirm catheter compatibility, deployment requirements and the instructions for use for the specific plug size before placement.
- MRI conditions and artifact information should be confirmed in the current manufacturer labeling; do not assume MRI safety from the device category alone.
- Potential contraindications and risks include unsuitable vascular anatomy, inability to safely reach the target vessel, non-target embolization, vessel injury, ischemia and access-site complications.
Procedures that use this device
Frequently Asked Questions
What are the clinical indications for the Reverse Medical Micro Vascular Plug System?
The device is indicated for the occlusion of blood vessels in various vascular pathologies, including neurovascular conditions and arterioportal fistulas.
What outcomes have been reported in clinical studies?
Clinical studies have reported successful embolization of vascular anomalies and effective vessel occlusion in neurovascular pathologies.
What complications have been reported?
Reported complications include those typical of endovascular procedures, but specific adverse events are not detailed in the available evidence.