Sterling Monorail PTA Balloon Dilatation Catheter Model H74939031-Xxxxxx
Contact Boston Scientific Corporation ↗ Compare similar devices
FDA Clearance Information
The Sterling Monorail PTA Balloon Dilatation Catheter, manufactured by Boston Scientific, received FDA clearance through the 510(k) pathway on December 16, 2005. It is classified as a Class 2 device under product code DQY.
What It Is
FDA-Cleared Indications
- Dilation of stenotic lesions in peripheral blood vessels during PTA.
- Treatment of peripheral vascular narrowing in vessels appropriate for the selected catheter and balloon size.
Clinical Applications
- Balloon angioplasty of peripheral arterial stenoses.
- Treatment of flow-limiting narrowing associated with peripheral artery disease.
- Dilation of selected lesions in the femoral, popliteal, and tibial arterial territories when the anatomy and device size are appropriate.
- Use with a compatible guidewire and vascular access system during image-guided endovascular treatment.
Reported off-label uses
- Balloon dilation of selected venous stenoses, such as iliac or central venous narrowing, may be performed in clinical practice but is not established here as a specific FDA-labeled indication.
- Use in other vascular territories or lesion types outside the device labeling may occur in specialized practice, based on physician judgment and available evidence.
Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.
Practical Considerations
- The catheter is available in multiple balloon diameters and working lengths; the selected size must match the target vessel and lesion.
- The monorail design is used over a compatible guidewire and requires appropriate introducer sheath and imaging equipment.
- Device handling, balloon inflation pressure, and lesion preparation should follow the current manufacturer instructions for use.
- MRI safety depends on the exact device configuration and labeling; verify the current Boston Scientific MRI information before scanning.
- Potential complications include dissection, perforation, thrombosis, embolization, bleeding at the access site, vessel recoil, and restenosis. Contraindications and warnings should be reviewed in the current labeling.
Frequently Asked Questions
What is the Sterling Monorail PTA Balloon Dilatation Catheter used for?
It is used for dilating narrowed or blocked blood vessels in peripheral artery disease (PAD) during percutaneous transluminal angioplasty (PTA) procedures.
What specialties typically use this device?
Interventional radiologists and vascular surgeons commonly use this device in their procedures.
What are the FDA-cleared indications?
The device is indicated for dilating stenotic segments of peripheral blood vessels, particularly in patients with peripheral artery disease (PAD).