📋 FDA Reference

WAVE PTA Balloon Catheter

WAVE Medical AG

Compare similar devices

Summary: The WAVE PTA Balloon Catheter is a percutaneous transluminal angioplasty catheter used to widen narrowed peripheral blood vessels. It is advanced over a guidewire and inflated across a stenosis under fluoroscopic imaging.

FDA Clearance Information

Pathway ? 510(k)
Number ? K260304 ↗
Decision Date ? May 20, 2026
Product Code ? LIT Catheter, Angioplasty, Peripheral, Transluminal
Device Class ? Class 2
Evidence ? 0 studies

FDA-Cleared Indications

  • Percutaneous transluminal angioplasty of stenotic lesions in peripheral arteries.
  • Treatment of peripheral arterial narrowing when balloon dilation is clinically indicated.
  • Use in the peripheral vasculature through catheter-based endovascular access.

Clinical Applications

  • Balloon angioplasty for peripheral arterial stenosis.
  • Treatment of narrowed iliac, femoropopliteal, or other peripheral arteries when the catheter size and labeling are appropriate.
  • Lesion preparation before placement of a peripheral vascular stent.
  • Treatment of residual narrowing after another peripheral endovascular intervention.

Reported off-label uses

  • Balloon angioplasty in dialysis access grafts or fistulas, when the specific device labeling does not include dialysis access and the treating clinician determines that off-label use is appropriate.

Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.

Practical Considerations

  • The available balloon diameters, lengths, shaft configuration, guidewire requirements, and sheath compatibility must be confirmed in the current device labeling.
  • The catheter is used with fluoroscopic imaging and requires vascular access, commonly through the common femoral artery or another appropriate peripheral access site.
  • Balloon inflation pressure should remain within the labeled rated burst pressure; the balloon must be completely deflated before repositioning or removal.
  • MRI safety depends on the device's current labeling and whether the catheter remains in the body; verify MR Safe, MR Conditional, or MR Unsafe status before scanning.
  • Potential complications include vessel dissection, perforation, thrombosis, embolization, bleeding at the access site, restenosis, contrast reaction, and kidney injury.

Procedures that use this device

Frequently Asked Questions

What is the WAVE PTA Balloon Catheter used for?

It is used for balloon angioplasty of narrowed peripheral arteries. The balloon is inflated across the stenosis to improve the vessel opening and blood flow.

Is the WAVE PTA Balloon Catheter MRI safe?

MRI status must be checked in the current manufacturer labeling. Do not assume the catheter is MRI safe or MRI conditional without confirming its exact configuration and whether it remains in the body.

What sizes does the WAVE PTA Balloon Catheter come in?

Balloon diameters, lengths, shaft types, guidewire requirements, and sheath compatibility vary by model. The current device label and product specifications should be reviewed for the exact size needed.

How long does a WAVE PTA Balloon Catheter last?

It is a single-use catheter intended for one procedure and should not be resterilized or reused. The treated artery may narrow again over time, depending on the disease and the intervention.

How much does a WAVE PTA Balloon Catheter cost?

The device price is generally part of the hospital or facility procedure charge rather than a separate patient bill. Patient costs vary with insurance coverage, facility fees, physician fees, imaging, and the treatment performed.

Disclaimer: This page compiles publicly available regulatory and published clinical evidence for educational reference. It does not constitute medical advice, product endorsement, or a recommendation for clinical use. Always consult manufacturer documentation and clinical judgment for patient care decisions.

📬 The IR Device Brief

One email a month: new FDA clearances, recalls and device pages in vascular & interventional radiology.

We'll email you a link to confirm. Unsubscribe any time.

Suggest edits

For manufacturers and their teams. Each field shows what the page says now: add, remove or rewrite anything, and leave the rest as is. LA Vascular reviews every change before it goes live.

About you