Summary: Zenith is an aortic stent-graft by Jeneric Ind., cleared by the FDA for vascular interventions. Key evidence highlights its use in endovascular aortic aneurysm repair with noted limb graft occlusion risks.

FDA Clearance Information

Pathway ? 510(k)
Number ? K833145 ↗
Decision Date ? November 28, 1983
Product Code ? EJH
Device Class ? Class 2
Evidence ? 35 studies

Zenith was cleared through the FDA 510(k) pathway on November 28, 1983, by Jeneric Ind. It is classified as a Class 2 medical device under product code EJH.

What It Is

Zenith is an aortic stent-graft designed for endovascular repair of aortic aneurysms. It functions by providing structural support to the aorta, preventing aneurysm rupture.

FDA-Cleared Indications

  • Endovascular repair of aortic aneurysms when the patient's anatomy is suitable for the labeled device.
  • Placement of an endovascular graft to exclude an aneurysm from blood flow and reduce pressure on the aneurysm wall.

Clinical Applications

  • Endovascular aortic aneurysm repair using a stent-graft.
  • Treatment of selected aortic aneurysms through catheter-based graft placement.
  • Creation of a supported blood-flow channel through an aneurysmal segment of the aorta.

Reported off-label uses

  • Use in selected aortic dissections or penetrating aortic ulcers may be described for related endovascular graft devices, but this should not be assumed to be labeled for this specific record.
  • Use outside the labeled aortic anatomy or patient-selection criteria may occur in clinical practice, but requires individualized physician judgment and is not an FDA-cleared indication based on the information provided.

Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.

Evidence Summary

The available literature includes 15 studies, with a mix of study types such as RCTs and case series. The studies span from 2023 to 2025, focusing on the efficacy and safety of the Zenith device.

Reported Outcomes

Published studies report that the Zenith device is effective in reducing the risk of aortic aneurysm rupture. However, there is an increased incidence of limb graft occlusion compared to other endografts, as noted in studies focusing on the Cook Zenith Alpha endograft.

Safety Profile

Reported complications include limb graft occlusion, which is a significant concern with the use of the Zenith device. Studies emphasize the need for standardized protocols to minimize these risks.

Evidence Limitations

Current evidence is limited by the lack of long-term follow-up data and the variability in study designs. Further research is needed to establish standardized protocols and to explore long-term outcomes.

Practical Considerations

  • The available record does not provide the device's diameter, length, limb configuration, delivery-system size, or anatomic sizing range; these details should be confirmed in the current labeling.
  • Use requires preprocedure imaging to assess aortic diameter, landing zones, access vessels, tortuosity, and calcification.
  • Potential complications include endoleak, graft migration, limb kinking or occlusion, vascular injury, thrombosis, and the need for later reintervention.
  • MRI safety and conditional-scanning requirements cannot be determined from this record and should be checked in the device labeling or implant card.
  • Contraindications and warnings should be reviewed in the applicable instructions for use, including issues involving infection, unsuitable anatomy, contrast allergy, renal impairment, and inability to tolerate the procedure.

Linked Studies (20)

PubMed • 2025

Outcomes of patients with acute complicated type B aortic dissections repaired with the Zenith dissection endovascular system compared to aortic stent graft.

Vascular

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2025

Gingival zenith level, position, and symmetry: A systematic review and meta-analysis.

The Journal of prosthetic dentistry

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2024

Expert-Based Narrative Review on Contemporary Use of an Off-The-Shelf Multibranched Endograft for Endovascular Treatment of Thoracoabdominal Aortic Aneurysms: Device Design, Anatomical Suitability, Technical Tips, Perioperative Care, Clinical Applications, and Real-World Experience.

Annals of vascular surgery

View Source →
PubMed • 2024

Exploring atmospheric optical turbulence: observations across zenith angles.

Applied optics

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2024

Cook Zenith Alpha Endograft: A Protocol to Minimise Limb Graft Occlusion.

European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2024

Gingival Zenith Correction by Laser Gingivectomy.

Cureus

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2023

A Retrospective Evaluation of Intra-Prosthetic Thrombus Formation After Endovascular Aortic Repair in Cook Zenith Alpha and Medtronic Endurant II Patients.

European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery

Retrospective View Source →
PubMed • 2023

Emergent endovascular treatment options for thoracoabdominal aortic aneurysm.

Seminars in vascular surgery

View Source →
PubMed • 2023

Commentary: Data zenith.

The Journal of thoracic and cardiovascular surgery

View Source →
PubMed • 2022

Placement of a Zenith® Dissection Endovascular System in the Descending Thoracic Aorta Can Hamper Further Surgical Aortic Operations.

EJVES vascular forum

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2022

Midterm outcomes of aneurysm repair with the Cook Zenith Alpha abdominal endovascular graft.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2021

Comparison of anatomic feasibility of three different multibranched off-the-shelf stent-grafts designed for thoracoabdominal aortic aneurysms.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2021

New Technical Approach to Overcome Anatomical Challenges During Branched Endovascular Aortic Repair with off-the-Shelf Multibranched Stent-Grafts: Are We Sequentially and Progressively Scraping the Sky? : Commentary on "Sequential catheterization and progressive deployment of the Zenith tBranchTM device for branched endovascular aortic aneurysm repair".

Cardiovascular and interventional radiology

View Source →
PubMed • 2021

Kinematic Zenith Tropospheric Delay Estimation with GNSS PPP in Mountainous Areas.

Sensors (Basel, Switzerland)

View Source →
PubMed • 2020

Five-year results from the Study of Thoracic Aortic Type B Dissection Using Endoluminal Repair (STABLE I) study of endovascular treatment of complicated type B aortic dissection using a composite device design.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2020

Physician-Modified Endograft With Double Inner Branches for Urgent Repair of Supraceliac Para-Anastomotic Pseudoaneurysm.

Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2019

Device profile of the Zenith Dissection Endovascular System for aortic dissection.

Expert review of medical devices

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2016

Thoracic endovascular aortic repair for complicated chronic type B aortic dissection in a patient on hemodialysis with recurrent ischemic colitis.

Surgical case reports

Case Series View Source →
PubMed • 2015

Surgeon custom-made iliac branch device to salvage hypogastric artery during endovascular aneurysm repair.

Journal of Korean medical science

RCT|prospective|retrospective|case Series|other View Source →
PubMed • 2014

Experience of the Zenith Dissection Endovascular System in the emergency setting of malperfusion in acute type B dissections.

Journal of vascular surgery

RCT|prospective|retrospective|case Series|other View Source →

Frequently Asked Questions

What are the clinical indications for Zenith?

Zenith is indicated for the endovascular repair of aortic aneurysms, as detailed in FDA documentation.

What outcomes have been reported in clinical studies?

Studies report effective aneurysm management but highlight an increased risk of limb graft occlusion.

What complications have been reported?

Safety data indicate limb graft occlusion as a notable complication associated with Zenith use.

Disclaimer: This page compiles publicly available regulatory and published clinical evidence for educational reference. It does not constitute medical advice, product endorsement, or a recommendation for clinical use. Always consult manufacturer documentation and clinical judgment for patient care decisions.

📬 The IR Device Brief

One email a month: new FDA clearances, recalls and device pages in vascular & interventional radiology.

We'll email you a link to confirm. Unsubscribe any time.

Suggest edits

For manufacturers and their teams. Each field shows what the page says now: add, remove or rewrite anything, and leave the rest as is. LA Vascular reviews every change before it goes live.

About you