Guidewires
Hi-Torque Floppy
A long, thin, sterile wire intended to be percutaneously placed into the cardiac vasculature (ventricles or coronary vessels) to function as a guide for the introduction, positioning, and/or operation of a device (e.g., catheter, pacing lead); it may also be used in the peripheral vasculature. It may be made of metal (e.g., stainless steel, Nitinol), or polymer and/or glass materials to provide MRI-compatibility, with or without coating, and is available in a variety of distal tip designs. It is used for various diagnostic and interventional procedures, and may include devices used to facilitate manipulation (e.g., torque device). This is a single-use device.
Hi-Torque Floppy models and sizes
From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.
| Model / catalog no. | Size | MRI | Status |
|---|---|---|---|
| 22219M-904 | Length 2.0 cm; Length 50 cm | Not stated | Available |
| 22299H | Guidewire Diameter 0.0140 in; Guidewire Length 190.0000 cm | Not stated | Available |
| 22299M | Guidewire Diameter 0.0140 in; Guidewire Length 190.0000 cm | Not stated | Available |
| 22299M-901 | Guidewire Diameter 0.0140 in; Guidewire Length 190.0000 cm | Not stated | Available |
| 22339H | Guidewire Diameter 0.0140 in; Guidewire Length 190.0000 cm | Not stated | Available |
| 22339M | Guidewire Diameter 0.0140 in; Guidewire Length 190.0000 cm | Not stated | Available |
| 22339M-901 | Length 2.0 cm; Length 50 cm | Not stated | Available |
| 22339M-903 | Guidewire Length 190.0000 cm; Guidewire Diameter 0.0140 in | Not stated | Available |
| 22339MJ | Length 2.0 cm; Length 190 cm | Not stated | Available |
| 22359M | Guidewire Length 300.0000 cm; Guidewire Diameter 0.0140 in | Not stated | Available |
| 22359M-901 | Guidewire Length 300.0000 cm; Guidewire Diameter 0.0140 in | Not stated | Available |
| 22359MJ | Guidewire Length 300.0000 cm; Guidewire Diameter 0.0140 in | Not stated | Available |
FDA clearances
- 510(k) K974773 March 1998
Procedures that use guidewires
Frequently asked questions
What is Hi-Torque Floppy used for?
A long, thin, sterile wire intended to be percutaneously placed into the cardiac vasculature (ventricles or coronary vessels) to function as a guide for the introduction, positioning, and/or operation of a device (e.g., catheter, pacing lead); it may also be used in the peripheral vasculature. It may be made of metal (e.g., stainless steel, Nitinol), or polymer and/or glass materials to provide MRI-compatibility, with or without coating, and is available in a variety of distal tip designs. It is used for various diagnostic and interventional procedures, and may include devices used to facilitate manipulation (e.g., torque device). This is a single-use device.
Who makes Hi-Torque Floppy?
Hi-Torque Floppy is made by Abbott Vascular Inc.. It is listed under guidewires in our device library.
What sizes does Hi-Torque Floppy come in?
Sizes listed for Hi-Torque Floppy: Guidewire Diameter: 0.01 in; Guidewire Length: 190–300 cm; Length: 2–190 cm. Confirm availability with the manufacturer's instructions for use.
Is Hi-Torque Floppy MRI safe?
The FDA device database entry for Hi-Torque Floppy does not state its MRI safety status. Check the labeling before MRI.
Is Hi-Torque Floppy FDA cleared?
Hi-Torque Floppy is covered by FDA submission K974773.
How do I contact a Abbott Vascular Inc. sales representative?
Abbott Vascular Inc. has not listed representatives on LA Vascular yet. Visit the Abbott Vascular Inc. company page for contact details.
Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.