Microcatheters

Bendit2.7 Steerable Microcatheter

by Bend It Technologies Ltd

A sterile, small-diameter, single-lumen, flexible tube designed for the controlled infusion of fluids (e.g., thrombolytics, diagnostic contrast media) into superselective small vessels (including intracranial, peripheral, or occluded coronary vasculature) for angiography/treatment, and typically also for the delivery of devices (e.g., embolization implants, guidewires) into tortuous vessels or across tight lesions. It may include an ultrasound transducer, a thermal sensor, and a hole for guidewire placement located at the distal tip. It is not a guide-catheter (i.e., is not intended to deliver other catheters or therapeutic leads directly through its lumen). This is a single-use device.

Contact a rep Compare similar devices

Bendit2.7 Steerable Microcatheter models and sizes

From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.

Model / catalog no.SizeMRIStatus
BDT01200— MR UnsafeAvailable

FDA clearances

  • 510(k) K200582 June 2020

Procedures that use microcatheters

Frequently asked questions

What is Bendit2.7 Steerable Microcatheter used for?

A sterile, small-diameter, single-lumen, flexible tube designed for the controlled infusion of fluids (e.g., thrombolytics, diagnostic contrast media) into superselective small vessels (including intracranial, peripheral, or occluded coronary vasculature) for angiography/treatment, and typically also for the delivery of devices (e.g., embolization implants, guidewires) into tortuous vessels or across tight lesions. It may include an ultrasound transducer, a thermal sensor, and a hole for guidewire placement located at the distal tip. It is not a guide-catheter (i.e., is not intended to deliver other catheters or therapeutic leads directly through its lumen). This is a single-use device.

Who makes Bendit2.7 Steerable Microcatheter?

Bendit2.7 Steerable Microcatheter is made by Bend It Technologies Ltd. It is listed under microcatheters in our device library.

What sizes does Bendit2.7 Steerable Microcatheter come in?

The FDA device database does not list sizes for Bendit2.7 Steerable Microcatheter. Check the instructions for use or ask a Bend It Technologies Ltd representative.

Is Bendit2.7 Steerable Microcatheter MRI safe?

The FDA device database lists Bendit2.7 Steerable Microcatheter as MR Unsafe. Always follow the specific MRI conditions in the labeling.

Is Bendit2.7 Steerable Microcatheter FDA cleared?

Bendit2.7 Steerable Microcatheter is covered by FDA submission K200582.

How do I contact a Bend It Technologies Ltd sales representative?

Bend It Technologies Ltd has not listed representatives on LA Vascular yet. Visit the Bend It Technologies Ltd company page for contact details.

Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.