A non-bioabsorbable tubular device intended to be implanted within the descending thoracic aorta to repair the vessel [includes repair of thoracic aortic aneurysm (TAA), traumatic transsections/dissections, fistulae, penetrating ulcers]; it is not intended for implantation within the aortic arch. It is typically made of a metal alloy [e.g., nickel-titanium alloy (Nitinol)] that forms an outer mesh structure with an inner synthetic polymer tube (endovascular graft) and is typically designed as a single continuous tube which may be used in singular and/or modular configurations. It is intended for percutaneous introduction; disposable delivery device (e.g., balloon catheter) may be included.

Contact a rep Compare similar devices

Relay Thoracic Stent-Graft with Plus Delivery System models and sizes

From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.

Model / catalog no.SizeMRIStatus
28M322090222290UOuter Diameter 22 mm; Length 90 mm; Catheter Gauge 22 Fr MR ConditionalAvailable
28M322150222290UCatheter Gauge 22 Fr; Length 150 mm; Outer Diameter 22 mm MR ConditionalAvailable
28M322190222290UCatheter Gauge 22 Fr; Length 190 mm; Outer Diameter 22 mm MR ConditionalAvailable
28M322250222390UCatheter Gauge 23 Fr; Length 250 mm; Outer Diameter 22 mm MR ConditionalAvailable
28M324090242290ULength 90 mm; Outer Diameter 24 mm; Catheter Gauge 22 Fr MR ConditionalAvailable
28M324150242290UCatheter Gauge 22 Fr; Length 150 mm; Outer Diameter 24 mm MR ConditionalAvailable
28M324190242290UCatheter Gauge 22 Fr; Length 190 mm; Outer Diameter 24 mm MR ConditionalAvailable
28M324250242390UCatheter Gauge 23 Fr; Length 250 mm; Outer Diameter 24 mm MR ConditionalAvailable
28M326155262290UCatheter Gauge 22 Fr; Length 155 mm; Outer Diameter 26 mm MR ConditionalAvailable
28M326195262290UCatheter Gauge 22 Fr; Length 195 mm; Outer Diameter 26 mm MR ConditionalAvailable
28M326250262390UCatheter Gauge 23 Fr; Length 250 mm; Outer Diameter 26 mm MR ConditionalAvailable
28M328095282290ULength 95 mm; Outer Diameter 28 mm; Catheter Gauge 22 Fr MR ConditionalAvailable
28M328155242290UCatheter Gauge 22 Fr; Length 155 mm; Outer Diameter 28 mm; Outer Diameter 24 mm MR ConditionalAvailable
28M328155282290UCatheter Gauge 22 Fr; Length 155 mm; Outer Diameter 28 mm MR ConditionalAvailable
28M328195242290UOuter Diameter 24 mm; Length 195 mm; Outer Diameter 28 mm; Catheter Gauge 22 Fr MR ConditionalAvailable
28M328195282290UCatheter Gauge 22 Fr; Length 195 mm; Outer Diameter 28 mm MR ConditionalAvailable
28M328250242390UOuter Diameter 24 mm; Length 250 mm; Outer Diameter 28 mm; Catheter Gauge 23 Fr MR ConditionalAvailable
28M328250282390UCatheter Gauge 23 Fr; Length 250 mm; Outer Diameter 28 mm MR ConditionalAvailable
28M330095302290ULength 95 mm; Outer Diameter 30 mm; Catheter Gauge 22 Fr MR ConditionalAvailable
28M330155262290UCatheter Gauge 22 Fr; Length 155 mm; Outer Diameter 30 mm; Outer Diameter 26 mm MR ConditionalAvailable
28M330155302290UCatheter Gauge 22 Fr; Length 155 mm; Outer Diameter 30 mm MR ConditionalAvailable
28M330200262390UCatheter Gauge 23 Fr; Outer Diameter 30 mm; Length 200 mm; Outer Diameter 26 mm MR ConditionalAvailable
28M330200302390UCatheter Gauge 23 Fr; Length 200 mm; Outer Diameter 30 mm MR ConditionalAvailable
28M330250262390UCatheter Gauge 23 Fr; Outer Diameter 30 mm; Length 250 mm; Outer Diameter 26 mm MR ConditionalAvailable
28M330250302390UCatheter Gauge 23 Fr; Length 250 mm; Outer Diameter 30 mm MR ConditionalAvailable
28M332095322290ULength 95 mm; Outer Diameter 32 mm; Catheter Gauge 22 Fr MR ConditionalAvailable
28M332155282290UCatheter Gauge 22 Fr; Length 155 mm; Outer Diameter 32 mm; Outer Diameter 28 mm MR ConditionalAvailable
28M332155322290UCatheter Gauge 22 Fr; Length 155 mm; Outer Diameter 32 mm MR ConditionalAvailable
28M332200282390UOuter Diameter 28 mm; Length 200 mm; Outer Diameter 32 mm; Catheter Gauge 23 Fr MR ConditionalAvailable
28M332200322390UCatheter Gauge 23 Fr; Length 200 mm; Outer Diameter 32 mm MR ConditionalAvailable
28M332250282490UOuter Diameter 28 mm; Length 250 mm; Outer Diameter 32 mm; Catheter Gauge 24 Fr MR ConditionalAvailable
28M332250322490UCatheter Gauge 24 Fr; Length 250 mm; Outer Diameter 32 mm MR ConditionalAvailable
28M334100342390UOuter Diameter 34 mm; Length 100 mm; Catheter Gauge 23 Fr MR ConditionalAvailable
28M334145302390UCatheter Gauge 23 Fr; Length 145 mm; Outer Diameter 34 mm; Outer Diameter 30 mm MR ConditionalAvailable
28M334145342390UCatheter Gauge 23 Fr; Length 145 mm; Outer Diameter 34 mm MR ConditionalAvailable
28M334200302490UCatheter Gauge 24 Fr; Outer Diameter 34 mm; Length 200 mm; Outer Diameter 30 mm MR ConditionalAvailable
28M334200342490UCatheter Gauge 24 Fr; Length 200 mm; Outer Diameter 34 mm MR ConditionalAvailable
28M334250302490UCatheter Gauge 24 Fr; Outer Diameter 34 mm; Length 250 mm; Outer Diameter 30 mm MR ConditionalAvailable
28M334250342490UCatheter Gauge 24 Fr; Length 250 mm; Outer Diameter 34 mm MR ConditionalAvailable
28M336100362390ULength 100 mm; Outer Diameter 36 mm; Catheter Gauge 23 Fr MR ConditionalAvailable
28M336145322490UCatheter Gauge 24 Fr; Length 145 mm; Outer Diameter 36 mm; Outer Diameter 32 mm MR ConditionalAvailable
28M336145362490UCatheter Gauge 24 Fr; Length 145 mm; Outer Diameter 36 mm MR ConditionalAvailable
28M336190322490UOuter Diameter 32 mm; Length 190 mm; Outer Diameter 36 mm; Catheter Gauge 24 Fr MR ConditionalAvailable
28M336190362490UCatheter Gauge 24 Fr; Length 190 mm; Outer Diameter 36 mm MR ConditionalAvailable
28M336250322490UOuter Diameter 32 mm; Length 250 mm; Outer Diameter 36 mm; Catheter Gauge 24 Fr MR ConditionalAvailable
28M336250362490UCatheter Gauge 24 Fr; Length 250 mm; Outer Diameter 36 mm MR ConditionalAvailable
28M338100382490ULength 100 mm; Outer Diameter 38 mm; Catheter Gauge 24 Fr MR ConditionalAvailable
28M338145342490UCatheter Gauge 24 Fr; Length 145 mm; Outer Diameter 38 mm; Outer Diameter 34 mm MR ConditionalAvailable
28M338145382490UCatheter Gauge 24 Fr; Length 145 mm; Outer Diameter 38 mm MR ConditionalAvailable
28M338190342590UCatheter Gauge 25 Fr; Outer Diameter 38 mm; Length 190 mm; Outer Diameter 34 mm MR ConditionalAvailable
28M338190382590UCatheter Gauge 25 Fr; Length 190 mm; Outer Diameter 38 mm MR ConditionalAvailable
28M338250342590UCatheter Gauge 25 Fr; Outer Diameter 38 mm; Length 250 mm; Outer Diameter 34 mm MR ConditionalAvailable
28M338250382590UCatheter Gauge 25 Fr; Length 250 mm; Outer Diameter 38 mm MR ConditionalAvailable
28M340105402490ULength 105 mm; Outer Diameter 40 mm; Catheter Gauge 24 Fr MR ConditionalAvailable
28M340145362590UOuter Diameter 40 mm; Length 145 mm; Catheter Gauge 25 Fr; Outer Diameter 36 mm MR ConditionalAvailable
28M340145402590UCatheter Gauge 25 Fr; Length 145 mm; Outer Diameter 40 mm MR ConditionalAvailable
28M340195362590UOuter Diameter 36 mm; Length 195 mm; Outer Diameter 40 mm; Catheter Gauge 25 Fr MR ConditionalAvailable
28M340195402590UCatheter Gauge 25 Fr; Length 195 mm; Outer Diameter 40 mm MR ConditionalAvailable
28M340250362590UOuter Diameter 36 mm; Length 250 mm; Outer Diameter 40 mm; Catheter Gauge 25 Fr MR ConditionalAvailable
28M340250402590UCatheter Gauge 25 Fr; Length 250 mm; Outer Diameter 40 mm MR ConditionalAvailable
28M342105422590ULength 105 mm; Outer Diameter 42 mm; Catheter Gauge 25 Fr MR ConditionalAvailable
28M342150382590UOuter Diameter 38 mm; Length 150 mm; Outer Diameter 42 mm; Catheter Gauge 25 Fr MR ConditionalAvailable
28M342150422590UCatheter Gauge 25 Fr; Length 150 mm; Outer Diameter 42 mm MR ConditionalAvailable
28M342195382590UCatheter Gauge 25 Fr; Outer Diameter 42 mm; Length 195 mm; Outer Diameter 38 mm MR ConditionalAvailable
28M342195422590UCatheter Gauge 25 Fr; Length 195 mm; Outer Diameter 42 mm MR ConditionalAvailable
28M342250382590UCatheter Gauge 25 Fr; Outer Diameter 42 mm; Length 250 mm; Outer Diameter 38 mm MR ConditionalAvailable
28M342250422590UCatheter Gauge 25 Fr; Length 250 mm; Outer Diameter 42 mm MR ConditionalAvailable
28M344105442590UCatheter Gauge 25 Fr; Length 105 mm; Outer Diameter 44 mm MR ConditionalAvailable
28M344155402590UOuter Diameter 40 mm; Length 155 mm; Outer Diameter 44 mm; Catheter Gauge 25 Fr MR ConditionalAvailable
28M344155442590UCatheter Gauge 25 Fr; Length 155 mm; Outer Diameter 44 mm MR ConditionalAvailable
28M344200402590UOuter Diameter 40 mm; Length 200 mm; Outer Diameter 44 mm; Catheter Gauge 25 Fr MR ConditionalAvailable
28M344200442590UCatheter Gauge 25 Fr; Length 200 mm; Outer Diameter 44 mm MR ConditionalAvailable
28M344250402690UOuter Diameter 40 mm; Length 250 mm; Outer Diameter 44 mm; Catheter Gauge 26 Fr MR ConditionalAvailable
28M344250442690UCatheter Gauge 26 Fr; Length 250 mm; Outer Diameter 44 mm MR ConditionalAvailable
28M346105462690UCatheter Gauge 26 Fr; Length 105 mm; Outer Diameter 46 mm MR ConditionalAvailable
28M346155422690UOuter Diameter 42 mm; Outer Diameter 46 mm; Length 155 mm; Catheter Gauge 26 Fr MR ConditionalAvailable
28M346155462690UCatheter Gauge 26 Fr; Length 155 mm; Outer Diameter 46 mm MR ConditionalAvailable
28M346200422690UCatheter Gauge 26 Fr; Outer Diameter 46 mm; Length 200 mm; Outer Diameter 42 mm MR ConditionalAvailable
28M346200462690UCatheter Gauge 26 Fr; Length 200 mm; Outer Diameter 46 mm MR ConditionalAvailable
28M346250422690UCatheter Gauge 26 Fr; Outer Diameter 46 mm; Length 250 mm; Outer Diameter 42 mm MR ConditionalAvailable
28M346250462690UCatheter Gauge 26 Fr; Length 250 mm; Outer Diameter 46 mm MR ConditionalAvailable
28M3260954262290ULength 95 mm; Outer Diameter 26 mm; Catheter Gauge 22 Fr MR ConditionalAvailable

FDA clearances

  • PMA P110038 September 2014

Procedures that use aortic stent grafts

Frequently asked questions

What is Relay Thoracic Stent-Graft with Plus Delivery System used for?

A non-bioabsorbable tubular device intended to be implanted within the descending thoracic aorta to repair the vessel [includes repair of thoracic aortic aneurysm (TAA), traumatic transsections/dissections, fistulae, penetrating ulcers]; it is not intended for implantation within the aortic arch. It is typically made of a metal alloy [e.g., nickel-titanium alloy (Nitinol)] that forms an outer mesh structure with an inner synthetic polymer tube (endovascular graft) and is typically designed as a single continuous tube which may be used in singular and/or modular configurations. It is intended for percutaneous introduction; disposable delivery device (e.g., balloon catheter) may be included.

Who makes Relay Thoracic Stent-Graft with Plus Delivery System?

Relay Thoracic Stent-Graft with Plus Delivery System is made by Bolton Medical Inc.. It is listed under aortic stent grafts (evar/tevar) in our device library.

What sizes does Relay Thoracic Stent-Graft with Plus Delivery System come in?

Sizes listed for Relay Thoracic Stent-Graft with Plus Delivery System: Outer Diameter: 22–46 mm; Catheter Gauge: 22–26 Fr; Length: 90–250 mm. Confirm availability with the manufacturer's instructions for use.

Is Relay Thoracic Stent-Graft with Plus Delivery System MRI safe?

The FDA device database lists Relay Thoracic Stent-Graft with Plus Delivery System as MR Conditional. Always follow the specific MRI conditions in the labeling.

Is Relay Thoracic Stent-Graft with Plus Delivery System FDA cleared?

Relay Thoracic Stent-Graft with Plus Delivery System is covered by FDA submission P110038.

How do I contact a Bolton Medical Inc. sales representative?

Bolton Medical Inc. has not listed representatives on LA Vascular yet. Visit the Bolton Medical Inc. company page for contact details.

Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.