Angiographic catheters

Goodale-Lubin

by Medtronic, Inc.

A thin, flexible tube designed to inject a contrast medium into select blood vessels of the cerebral, visceral, or peripheral vasculature during an angiographic procedure in order to facilitate the clear visualization of the vascular system of a targeted organ or area of the body. It is introduced percutaneously, has a radiopaque marker(s) for positioning, and may include disposable devices dedicated to catheter introduction/function [e.g., sheath(s)]. It may also be used for simultaneous pressure measurements to determine the transvalvular, intravascular, and intraventricular pressure gradients. This is a single-use device.

Contact a rep Compare similar devices

Goodale-Lubin models and sizes

From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.

Model / catalog no.SizeMRIStatus
001279Lumen/Inner Diameter 0.889 mm; Catheter Gauge 5.0 Fr; Length 80.0 cm Not statedAvailable
001279Catheter Gauge 5.0 Fr; Length 80.0 cm; Lumen/Inner Diameter 0.889 mm Not statedAvailable
001283Lumen/Inner Diameter 1.194 mm; Catheter Gauge 6.0 Fr; Length 80.0 cm Not statedAvailable
001283Catheter Gauge 6.0 Fr; Length 80.0 cm; Lumen/Inner Diameter 1.194 mm Not statedAvailable
001284Length 100.0 cm; Catheter Gauge 6.0 Fr; Lumen/Inner Diameter 1.194 mm Not statedAvailable
001284Length 100.0 cm; Lumen/Inner Diameter 1.194 mm; Catheter Gauge 6.0 Fr Not statedAvailable
001288Lumen/Inner Diameter 1.499 mm; Length 100.0 cm; Catheter Gauge 7.0 Fr Not statedAvailable
001288Catheter Gauge 7.0 Fr; Lumen/Inner Diameter 1.499 mm; Length 100.0 cm Not statedAvailable
001453Catheter Gauge 5.0 Fr; Length 50.0 cm; Lumen/Inner Diameter 0.711 mm Not statedAvailable
001453Length 50.0 cm; Lumen/Inner Diameter 0.711 mm; Catheter Gauge 5.0 Fr Not statedAvailable
001458Catheter Gauge 6.0 Fr; Lumen/Inner Diameter 0.965 mm; Length 100.0 cm Not statedAvailable
001458Length 100.0 cm; Lumen/Inner Diameter 0.965 mm; Catheter Gauge 6.0 Fr Not statedAvailable
007459Length 100.0 cm; Catheter Gauge 7.0 Fr; Lumen/Inner Diameter 1.219 mm Not statedAvailable
007459Lumen/Inner Diameter 1.219 mm; Catheter Gauge 7.0 Fr; Length 100.0 cm Not statedAvailable
007460Length 125.0 cm; Lumen/Inner Diameter 1.219 mm; Catheter Gauge 7.0 Fr Not statedAvailable
007460Length 125.0 cm; Lumen/Inner Diameter 1.219 mm; Catheter Gauge 7.0 Fr Not statedAvailable
007462Length 125.0 cm; Catheter Gauge 8.0 Fr; Lumen/Inner Diameter 1.448 mm Not statedAvailable
007462Length 125.0 cm; Catheter Gauge 8.0 Fr; Lumen/Inner Diameter 1.448 mm Not statedAvailable
990102Catheter Gauge 5.0 Fr; Length 60.0 cm; Lumen/Inner Diameter 0.711 mm Not statedAvailable
990102Lumen/Inner Diameter 0.711 mm; Catheter Gauge 5.0 Fr; Length 60.0 cm Not statedAvailable
990104Lumen/Inner Diameter 1.219 mm; Catheter Gauge 7.0 Fr; Length 80.0 cm Not statedAvailable
990104Catheter Gauge 7.0 Fr; Length 80.0 cm; Lumen/Inner Diameter 1.219 mm Not statedAvailable
990105Lumen/Inner Diameter 0.965 mm; Catheter Gauge 6.0 Fr; Length 60.0 cm Not statedAvailable
990105Catheter Gauge 6.0 Fr; Length 60.0 cm; Lumen/Inner Diameter 0.965 mm Not statedAvailable
990106Length 125.0 cm; Catheter Gauge 6.0 Fr; Lumen/Inner Diameter 0.965 mm Not statedAvailable
990106Lumen/Inner Diameter 0.965 mm; Length 125.0 cm; Catheter Gauge 6.0 Fr Not statedAvailable
990108Lumen/Inner Diameter 1.219 mm; Length 60.0 cm; Catheter Gauge 7.0 Fr Not statedAvailable
990108Lumen/Inner Diameter 1.219 mm; Catheter Gauge 7.0 Fr; Length 60.0 cm Not statedAvailable
990109Length 100.0 cm; Lumen/Inner Diameter 1.448 mm; Catheter Gauge 8.0 Fr Not statedAvailable

Procedures that use angiographic catheters

Frequently asked questions

What is Goodale-Lubin used for?

A thin, flexible tube designed to inject a contrast medium into select blood vessels of the cerebral, visceral, or peripheral vasculature during an angiographic procedure in order to facilitate the clear visualization of the vascular system of a targeted organ or area of the body. It is introduced percutaneously, has a radiopaque marker(s) for positioning, and may include disposable devices dedicated to catheter introduction/function [e.g., sheath(s)]. It may also be used for simultaneous pressure measurements to determine the transvalvular, intravascular, and intraventricular pressure gradients. This is a single-use device.

Who makes Goodale-Lubin?

Goodale-Lubin is made by Medtronic, Inc.. It is listed under angiographic catheters in our device library.

What sizes does Goodale-Lubin come in?

Sizes listed for Goodale-Lubin: Catheter Gauge: 5–8 Fr; Length: 50–125 cm; Lumen/Inner Diameter: 0.71–1.5 mm. Confirm availability with the manufacturer's instructions for use.

Is Goodale-Lubin MRI safe?

The FDA device database entry for Goodale-Lubin does not state its MRI safety status. Check the labeling before MRI.

Is Goodale-Lubin FDA cleared?

Goodale-Lubin is registered in the FDA's Global Unique Device Identification Database (GUDID).

How do I contact a Medtronic, Inc. sales representative?

Medtronic, Inc. has not listed representatives on LA Vascular yet. Visit the Medtronic, Inc. company page for contact details.

Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.