Guidewires

Zinger Light

by Medtronic, Inc.

A long, thin, sterile wire intended to be percutaneously placed into the cardiac vasculature (ventricles or coronary vessels) to function as a guide for the introduction, positioning, and/or operation of a device (e.g., catheter, pacing lead); it may also be used in the peripheral vasculature. It may be made of metal (e.g., stainless steel, Nitinol), or polymer and/or glass materials to provide MRI-compatibility, with or without coating, and is available in a variety of distal tip designs. It is used for various diagnostic and interventional procedures, and may include devices used to facilitate manipulation (e.g., torque device). This is a single-use device.

Contact a rep Compare similar devices

Zinger Light models and sizes

From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.

Model / catalog no.SizeMRIStatus
LVZRLS180JLength 180.0 cm; Outer Diameter 0.014 in Not statedAvailable
LVZRLS180SOuter Diameter 0.014 in; Length 180.0 cm Not statedAvailable
ZNGRLS180HJOuter Diameter 0.014 in; Length 180.0 cm Not statedAvailable
ZNGRLS180HJLength 180.0 cm; Outer Diameter 0.014 in Not statedAvailable
ZNGRLS180HSOuter Diameter 0.014 in; Length 180.0 cm Not statedAvailable
ZNGRLS180HSOuter Diameter 0.014 in; Length 180.0 cm Not statedAvailable
ZNGRLS180JLength 180.0 cm; Outer Diameter 0.014 in Not statedAvailable
ZNGRLS180JLength 180.0 cm; Outer Diameter 0.014 in Not statedAvailable
ZNGRLS180SLength 180.0 cm; Outer Diameter 0.014 in Not statedAvailable
ZNGRLS180SLength 180.0 cm; Outer Diameter 0.014 in Not statedAvailable
ZNGRLS300HJLength 300.0 cm; Outer Diameter 0.014 in Not statedAvailable
ZNGRLS300HJLength 300.0 cm; Outer Diameter 0.014 in Not statedAvailable
ZNGRLS300HSLength 300.0 cm; Outer Diameter 0.014 in Not statedAvailable
ZNGRLS300HSOuter Diameter 0.014 in; Length 300.0 cm Not statedAvailable
ZNGRLS300JOuter Diameter 0.014 in; Length 300.0 cm Not statedAvailable
ZNGRLS300JLength 300.0 cm; Outer Diameter 0.014 in Not statedAvailable
ZNGRLS300SLength 300.0 cm; Outer Diameter 0.014 in Not statedAvailable
ZNGRLS300SLength 300.0 cm; Outer Diameter 0.014 in Not statedAvailable

FDA clearances

  • 510(k) K140695 June 2014

Procedures that use guidewires

Frequently asked questions

What is Zinger Light used for?

A long, thin, sterile wire intended to be percutaneously placed into the cardiac vasculature (ventricles or coronary vessels) to function as a guide for the introduction, positioning, and/or operation of a device (e.g., catheter, pacing lead); it may also be used in the peripheral vasculature. It may be made of metal (e.g., stainless steel, Nitinol), or polymer and/or glass materials to provide MRI-compatibility, with or without coating, and is available in a variety of distal tip designs. It is used for various diagnostic and interventional procedures, and may include devices used to facilitate manipulation (e.g., torque device). This is a single-use device.

Who makes Zinger Light?

Zinger Light is made by Medtronic, Inc.. It is listed under guidewires in our device library.

What sizes does Zinger Light come in?

Sizes listed for Zinger Light: Outer Diameter: 0.01 in; Length: 180–300 cm. Confirm availability with the manufacturer's instructions for use.

Is Zinger Light MRI safe?

The FDA device database entry for Zinger Light does not state its MRI safety status. Check the labeling before MRI.

Is Zinger Light FDA cleared?

Zinger Light is covered by FDA submission K140695.

How do I contact a Medtronic, Inc. sales representative?

Medtronic, Inc. has not listed representatives on LA Vascular yet. Visit the Medtronic, Inc. company page for contact details.

Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.