A long, thin, sterile wire intended to be percutaneously placed into the cardiac vasculature (ventricles or coronary vessels) to function as a guide for the introduction, positioning, and/or operation of a device (e.g., catheter, pacing lead); it may also be used in the peripheral vasculature. It may be made of metal (e.g., stainless steel, Nitinol), or polymer and/or glass materials to provide MRI-compatibility, with or without coating, and is available in a variety of distal tip designs. It is used for various diagnostic and interventional procedures, and may include devices used to facilitate manipulation (e.g., torque device). This is a single-use device.

Contact a rep Compare similar devices

Navilyst models and sizes

From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.

Model / catalog no.SizeMRIStatus
45746Length 70 cm; Outer Diameter 0.018 in Not statedAvailable
45747Length 145 cm; Outer Diameter 0.018 in Not statedAvailable
96000217Outer Diameter 0.035 in; Length 150 cm Not statedAvailable
96000218Length 150 cm; Outer Diameter 0.035 in Not statedAvailable
96000301Outer Diameter 0.035 in; Length 150 cm Not statedAvailable
96000302Length 150 cm; Outer Diameter 0.035 in Not statedAvailable
96000303Outer Diameter 0.035 in; Length 150 cm Not statedAvailable
96000304Length 150 Feet; Outer Diameter 0.035 in Not statedAvailable
96000603Length 150 cm; Outer Diameter 0.035 in Not statedAvailable
96000604Outer Diameter 0.035 in; Length 150 cm Not statedAvailable
97000101Length 145 cm; Outer Diameter 0.035 in Not statedAvailable
97000102Outer Diameter 0.035 in; Length 145 cm Not statedAvailable
97000103Outer Diameter 0.038 in; Length 145 cm Not statedAvailable
97000104Outer Diameter 0.038 in; Length 145 cm Not statedAvailable
97000105Length 145 cm; Outer Diameter 0.035 in Not statedAvailable
97000106Length 145 cm; Outer Diameter 0.038 in Not statedAvailable
97000107Length 145 cm; Outer Diameter 0.025 in Not statedAvailable
97000108Length 60 cm; Outer Diameter 0.018 in Not statedAvailable
97000109Outer Diameter 0.025 in; Length 60 cm Not statedAvailable
97000112Outer Diameter 0.038 in; Length 145 cm Not statedAvailable
97000113Length 60 cm; Outer Diameter 0.032 in Not statedAvailable
97000201Length 175 cm; Outer Diameter 0.035 in Not statedAvailable
97000202Length 145 cm; Outer Diameter 0.035 in Not statedAvailable
97000203Outer Diameter 0.035 in; Length 145 cm Not statedAvailable
97000205Length 145 cm; Outer Diameter 0.038 in Not statedAvailable
97000206Outer Diameter 0.038 in; Length 145 cm Not statedAvailable
97000208Length 145 cm; Outer Diameter 0.035 in Not statedAvailable
97000210Outer Diameter 0.035 in; Length 175 cm Not statedAvailable
97000211Length 175 cm; Outer Diameter 0.038 in Not statedAvailable
97000216Length 145 cm; Outer Diameter 0.025 in Not statedAvailable
97000217Outer Diameter 0.035 in; Length 145 cm Not statedAvailable
97000219Outer Diameter 0.035 in; Length 145 cm Not statedAvailable
97000222Length 145 cm; Outer Diameter 0.035 in Not statedAvailable
97000232Outer Diameter 0.032 in; Length 145 cm Not statedAvailable
97000233Length 145 cm; Outer Diameter 0.038 in Not statedAvailable
97000235Length 145 cm; Outer Diameter 0.035 in Not statedAvailable
97000302Outer Diameter 0.038 in; Length 145 cm Not statedAvailable
97000303Length 145 cm; Outer Diameter 0.035 in Not statedAvailable
97000307Length 145 cm; Outer Diameter 0.035 in Not statedAvailable
97000401Outer Diameter 0.035 in; Length 260 cm Not statedAvailable
97000402Outer Diameter 0.038 in; Length 260 cm Not statedAvailable
97000405Outer Diameter 0.035 in; Length 260 cm Not statedAvailable
97000406Outer Diameter 0.038 in; Length 260 cm Not statedAvailable
97000501Outer Diameter 0.035 in; Length 145 cm Not statedAvailable
97000503Outer Diameter 0.038 in; Length 145 cm Not statedAvailable
97000504Length 145 cm; Outer Diameter 0.038 in Not statedAvailable
97000505Outer Diameter 0.035 in; Length 145 cm Not statedAvailable
97000507Outer Diameter 0.032 in; Length 145 cm Not statedAvailable
97000508Outer Diameter 0.038 in; Length 175 cm Not statedAvailable
97000601Outer Diameter 0.035 in; Length 145 cm Not statedAvailable
97000602Length 145 cm; Outer Diameter 0.038 in Not statedAvailable

Procedures that use guidewires

Frequently asked questions

What is Navilyst used for?

A long, thin, sterile wire intended to be percutaneously placed into the cardiac vasculature (ventricles or coronary vessels) to function as a guide for the introduction, positioning, and/or operation of a device (e.g., catheter, pacing lead); it may also be used in the peripheral vasculature. It may be made of metal (e.g., stainless steel, Nitinol), or polymer and/or glass materials to provide MRI-compatibility, with or without coating, and is available in a variety of distal tip designs. It is used for various diagnostic and interventional procedures, and may include devices used to facilitate manipulation (e.g., torque device). This is a single-use device.

Who makes Navilyst?

Navilyst is made by Navilyst Medical, Inc.. It is listed under guidewires in our device library.

What sizes does Navilyst come in?

Sizes listed for Navilyst: Outer Diameter: 0.02–0.04 in; Length: 60–260 cm; Length: 150 Feet. Confirm availability with the manufacturer's instructions for use.

Is Navilyst MRI safe?

The FDA device database entry for Navilyst does not state its MRI safety status. Check the labeling before MRI.

Is Navilyst FDA cleared?

Navilyst is registered in the FDA's Global Unique Device Identification Database (GUDID).

How do I contact a Navilyst Medical, Inc. sales representative?

Navilyst Medical, Inc. has not listed representatives on LA Vascular yet. Visit the Navilyst Medical, Inc. company page for contact details.

Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.

📬 The IR Device Brief

One email a month: new FDA clearances, recalls and device pages in vascular & interventional radiology.

We'll email you a link to confirm. Unsubscribe any time.

Suggest edits

For manufacturers and their teams. Each field shows what the page says now: add, remove or rewrite anything, and leave the rest as is. LA Vascular reviews every change before it goes live.

About you