Microcatheters

Neuron

by Penumbra, Inc.

A sterile, small-diameter, single-lumen, flexible tube designed for the controlled infusion of fluids (e.g., thrombolytics, diagnostic contrast media) into superselective small vessels (including intracranial, peripheral, or occluded coronary vasculature) for angiography/treatment, and typically also for the delivery of devices (e.g., embolization implants, guidewires) into tortuous vessels or across tight lesions. It may include an ultrasound transducer, a thermal sensor, and a hole for guidewire placement located at the distal tip. It is not a guide-catheter (i.e., is not intended to deliver other catheters or therapeutic leads directly through its lumen). This is a single-use device.

Contact a rep Compare similar devices

Neuron models and sizes

From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.

Model / catalog no.SizeMRIStatus
PNMD8F0881004β€” Not statedAvailable
PNMD8F0881004Mβ€” Not statedAvailable
PNMD8F088704β€” Not statedAvailable
PNMD8F088704Mβ€” Not statedAvailable
PNMD8F088804β€” Not statedAvailable
PNMD8F088804Mβ€” Not statedAvailable
PNMD8F088904β€” Not statedAvailable
PNMD8F088904Mβ€” Not statedAvailable
PNML6F0881004β€” Not statedAvailable
PNML6F0881004-Rβ€” Not statedAvailable
PNML6F0881004Mβ€” Not statedAvailable
PNML6F0881004M-Rβ€” Not statedAvailable
PNML6F0881004MRβ€” Not statedAvailable
PNML6F0881004Rβ€” Not statedAvailable
PNML6F088704β€” Not statedAvailable
PNML6F088704Mβ€” Not statedAvailable
PNML6F088704MRβ€” Not statedAvailable
PNML6F088704Rβ€” Not statedAvailable
PNML6F088804β€” Not statedAvailable
PNML6F088804-Rβ€” Not statedAvailable
PNML6F088804Mβ€” Not statedAvailable
PNML6F088804M-Rβ€” Not statedAvailable
PNML6F088804MRβ€” Not statedAvailable
PNML6F088804Rβ€” Not statedAvailable
PNML6F088904β€” Not statedAvailable
PNML6F088904-Rβ€” Not statedAvailable
PNML6F088904Mβ€” Not statedAvailable
PNML6F088904M-Rβ€” Not statedAvailable
PNML6F088904MRβ€” Not statedAvailable
PNML6F088904Rβ€” Not statedAvailable
PNS5F120BERβ€” Not statedAvailable
PNS5F120BER-ALength 120 cm Not statedAvailable
PNS5F120BER-Rβ€” Not statedAvailable
PNS5F120H1β€” Not statedAvailable
PNS5F120H1-Rβ€” Not statedAvailable
PNS5F120SIMβ€” Not statedAvailable
PNS5F120SIM-Rβ€” Not statedAvailable
PNS5F130BERβ€” Not statedAvailable
PNS5F130BER-Rβ€” Not statedAvailable
PNS5F130H1β€” Not statedAvailable
PNS5F130H1-Rβ€” Not statedAvailable
PNS5F130SIMβ€” Not statedAvailable
PNS5F130SIM-Rβ€” Not statedAvailable
PNS6F105BERβ€” Not statedAvailable
PNS6F105BER-RLength 105 cm Not statedAvailable
PNS6F105H1β€” Not statedAvailable
PNS6F105H1-RLength 105 cm Not statedAvailable
PNS6F105SIMβ€” Not statedAvailable
PNS6F105SIMVβ€” Not statedAvailable
PNS6F125BERβ€” Not statedAvailable
PNS6F125BER-RLength 125 cm Not statedAvailable
PNS6F125H1β€” Not statedAvailable
PNS6F125H1-RLength 125 cm Not statedAvailable
PNS6F125SIMβ€” Not statedAvailable
PNS6F125SIM-RLength 125 cm Not statedAvailable
PNS6F125SIMVβ€” Not statedAvailable
PNS6F125SIMV-RLength 120 cm Not statedAvailable

FDA clearances

Procedures that use microcatheters

Frequently asked questions

What is Neuron used for?

A sterile, small-diameter, single-lumen, flexible tube designed for the controlled infusion of fluids (e.g., thrombolytics, diagnostic contrast media) into superselective small vessels (including intracranial, peripheral, or occluded coronary vasculature) for angiography/treatment, and typically also for the delivery of devices (e.g., embolization implants, guidewires) into tortuous vessels or across tight lesions. It may include an ultrasound transducer, a thermal sensor, and a hole for guidewire placement located at the distal tip. It is not a guide-catheter (i.e., is not intended to deliver other catheters or therapeutic leads directly through its lumen). This is a single-use device.

Who makes Neuron?

Neuron is made by Penumbra, Inc.. It is listed under microcatheters in our device library.

What sizes does Neuron come in?

Sizes listed for Neuron: Length: 105–125 cm. Confirm availability with the manufacturer's instructions for use.

Is Neuron MRI safe?

The FDA device database entry for Neuron does not state its MRI safety status. Check the labeling before MRI.

Is Neuron FDA cleared?

Neuron is covered by FDA submissions K070970, K111380, K083125.

How do I contact a Penumbra, Inc. sales representative?

Penumbra, Inc. has not listed representatives on LA Vascular yet. Visit the Penumbra, Inc. company page for contact details.

Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.