Microcatheters

Plato

by Scientia Vascular LLC

A sterile, small-diameter, single-lumen, flexible tube designed for the controlled infusion of fluids (e.g., thrombolytics, diagnostic contrast media) into superselective small vessels (including intracranial, peripheral, or occluded coronary vasculature) for angiography/treatment, and typically also for the delivery of devices (e.g., embolization implants, guidewires) into tortuous vessels or across tight lesions. It may include an ultrasound transducer, a thermal sensor, and a hole for guidewire placement located at the distal tip. It is not a guide-catheter (i.e., is not intended to deliver other catheters or therapeutic leads directly through its lumen). This is a single-use device.

Contact a rep Compare similar devices

Plato models and sizes

From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.

Model / catalog no.SizeMRIStatus
17-160-000Catheter Inner Diameter 0.017 in; Catheter Working Length 160 cm; Outer Diameter 0.57 mm; Pressure 300 Pound per Square Inch MR UnsafeAvailable
17-160-045Catheter Inner Diameter 0.017 in; Catheter Working Length 160 cm; Pressure 300 Pound per Square Inch; Outer Diameter 0.57 mm MR UnsafeAvailable
17-160-090Catheter Inner Diameter 0.017 in; Catheter Working Length 160 cm; Outer Diameter 0.57 mm; Pressure 300 Pound per Square Inch MR UnsafeAvailable
27B— MR UnsafeAvailable

FDA clearances

  • 510(k) K223560 August 2023
  • 510(k) K210601 April 2021
  • 510(k) K170406 April 2017
  • 510(k) K143398 June 2015

Procedures that use microcatheters

Frequently asked questions

What is Plato used for?

A sterile, small-diameter, single-lumen, flexible tube designed for the controlled infusion of fluids (e.g., thrombolytics, diagnostic contrast media) into superselective small vessels (including intracranial, peripheral, or occluded coronary vasculature) for angiography/treatment, and typically also for the delivery of devices (e.g., embolization implants, guidewires) into tortuous vessels or across tight lesions. It may include an ultrasound transducer, a thermal sensor, and a hole for guidewire placement located at the distal tip. It is not a guide-catheter (i.e., is not intended to deliver other catheters or therapeutic leads directly through its lumen). This is a single-use device.

Who makes Plato?

Plato is made by Scientia Vascular LLC. It is listed under microcatheters in our device library.

What sizes does Plato come in?

Sizes listed for Plato: Catheter Inner Diameter: 0.02 in; Catheter Working Length: 160 cm; Outer Diameter: 0.57 mm. Confirm availability with the manufacturer's instructions for use.

Is Plato MRI safe?

The FDA device database lists Plato as MR Unsafe. Always follow the specific MRI conditions in the labeling.

Is Plato FDA cleared?

Plato is covered by FDA submissions K143398, K170406, K210601, K223560.

How do I contact a Scientia Vascular LLC sales representative?

Scientia Vascular LLC has not listed representatives on LA Vascular yet. Visit the Scientia Vascular LLC company page for contact details.

Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.