WEB devices
WEB Detachment Controller
A noninvasive, hand-held, electrically-powered unit intended to deliver a low-level electric current to break the connection between a vascular implantable device (typically a neurovascular or peripheral embolization coil or stent) and its deployment device (i.e., implant inserter or delivery wire) via an electrolytic reaction. It is intended to connect to the proximal end of an appropriate implant inserter (delivery wire) which conducts the current to the electrically-unstable detachment point. This is a single-use device.
Where to buy WEB Detachment Controller
We do not have contact details for Sequent Medical, Inc. yet. Send a request and we will route it to the right person for your country.
WEB Detachment Controller models and sizes
From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.
| Model / catalog no. | Size | MRI | Status |
|---|---|---|---|
| WDC-1 | — | Not stated | Available |
FDA clearances
- PMA P170032 January 2021
Procedures that use web devices
Frequently asked questions
What is WEB Detachment Controller used for?
A noninvasive, hand-held, electrically-powered unit intended to deliver a low-level electric current to break the connection between a vascular implantable device (typically a neurovascular or peripheral embolization coil or stent) and its deployment device (i.e., implant inserter or delivery wire) via an electrolytic reaction. It is intended to connect to the proximal end of an appropriate implant inserter (delivery wire) which conducts the current to the electrically-unstable detachment point. This is a single-use device.
Who makes WEB Detachment Controller?
WEB Detachment Controller is made by Sequent Medical, Inc.. It is listed under intrasaccular flow disruption devices (web) in our device library.
What sizes does WEB Detachment Controller come in?
The FDA device database does not list sizes for WEB Detachment Controller. Check the instructions for use or ask a Sequent Medical, Inc. representative.
Is WEB Detachment Controller MRI safe?
The FDA device database entry for WEB Detachment Controller does not state its MRI safety status. Check the labeling before MRI.
Is WEB Detachment Controller FDA cleared?
WEB Detachment Controller is covered by FDA submission P170032.
How do I contact a Sequent Medical, Inc. sales representative?
Sequent Medical, Inc. has not listed representatives on LA Vascular yet. Visit the Sequent Medical, Inc. company page for contact details.
Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.