Venous stents
Vici Venous Stent System
by Veniti Inc
A non-bioabsorbable, tubular device made of metal intended to be implanted in a peripheral (typically the iliac and/or femoral) vein to maintain patency in patients with constrained venous outflow; it is not intended for coronary or intracranial venous stenting. It is inserted and advanced to the site of implantation with a dedicated catheter where it self-expands upon release. It is typically made of nickel-titanium alloy (Nitinol) and has radiopaque marker(s) for visualization; it is available in a variety of diameters and lengths. Disposable devices associated with implantation may be included.
Vici Venous Stent System models and sizes
From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.
| Model / catalog no. | Size | MRI | Status |
|---|---|---|---|
| H74912060100 | Length 100 cm; Stent Length 60 mm; Stent Diameter 12 mm | MR Conditional | Available |
| H74912090100 | Stent Length 90 mm; Length 100 cm; Stent Diameter 12 mm | MR Conditional | Available |
| H74912120100 | Stent Diameter 12 mm; Stent Length 120 mm; Length 100 cm | MR Conditional | Available |
| H74914060100 | Stent Diameter 14 mm; Length 100 cm; Stent Length 60 mm | MR Conditional | Available |
| H74914090100 | Stent Diameter 14 mm; Stent Length 90 mm; Length 100 cm | MR Conditional | Available |
| H74914120100 | Stent Length 120 mm; Stent Diameter 14 mm; Length 100 cm | MR Conditional | Available |
| H74916060100 | Stent Length 60 mm; Stent Diameter 16 mm; Length 100 cm | MR Conditional | Available |
| H74916090100 | Length 100 cm; Stent Length 90 mm; Stent Diameter 16 mm | MR Conditional | Available |
| H74916120100 | Stent Length 120 mm; Stent Diameter 16 mm; Length 100 cm | MR Conditional | Available |
FDA clearances
- PMA P180013 June 2021
Procedures that use venous stents
Frequently asked questions
What is Vici Venous Stent System used for?
A non-bioabsorbable, tubular device made of metal intended to be implanted in a peripheral (typically the iliac and/or femoral) vein to maintain patency in patients with constrained venous outflow; it is not intended for coronary or intracranial venous stenting. It is inserted and advanced to the site of implantation with a dedicated catheter where it self-expands upon release. It is typically made of nickel-titanium alloy (Nitinol) and has radiopaque marker(s) for visualization; it is available in a variety of diameters and lengths. Disposable devices associated with implantation may be included.
Who makes Vici Venous Stent System?
Vici Venous Stent System is made by Veniti Inc. It is listed under venous stents in our device library.
What sizes does Vici Venous Stent System come in?
Sizes listed for Vici Venous Stent System: Stent Length: 60–120 mm; Stent Diameter: 12–16 mm; Length: 100 cm. Confirm availability with the manufacturer's instructions for use.
Is Vici Venous Stent System MRI safe?
The FDA device database lists Vici Venous Stent System as MR Conditional. Always follow the specific MRI conditions in the labeling.
Is Vici Venous Stent System FDA cleared?
Vici Venous Stent System is covered by FDA submission P180013.
How do I contact a Veniti Inc sales representative?
Veniti Inc has not listed representatives on LA Vascular yet. Visit the Veniti Inc company page for contact details.
Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.