18 product lines across 5 device categories: Angiographic catheters, Embolic beads, Guidewires, Microcatheters, TR bands.
Angiographic Catheters
Used in: Uterine Artery Embolization (UAE), Internal Iliac Artery Embolization
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| Langston dual lumen catheter Each LANGSTON dual lumen catheter is indicated for delivery of contrast medium in angiographic studies and for simultaneous pressure measurement from two… | Catheter Gauge: 6β7 Fr | 4 | Not stated |
| Gandras catheters The GANDRAS catheter is designed to be used for delivering embolic materials and radiopaque media to selected sites in the vascular system.… | Length: 84β86 cm; Catheter Gauge: 5 Fr | 2 | Not stated |
| Gandras catheter | Catheter Gauge: 5 Fr; Length: 82 cm | 1 | Not stated |
| Gandras VISCI-G catheter The GANDRAS VISCI-G catheter is designed to be used for delivering embolic materials and radiopaque media to selected sites in the vascular… | Catheter Gauge: 5 Fr; Length: 75 cm | 1 | Not stated |
Embolic Microspheres and Particles (Beads)
Used in: Uterine Artery Embolization (UAE), Prostate Artery Embolization (PAE), Genicular Artery Embolization (GAE), Transarterial Chemoembolization (TACE), Portal Vein Embolization, Middle Meningeal Artery Embolization
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| Gel-Bead Embolization Spheres | β | 10 | Not stated |
Guidewires
Used in: Uterine Artery Embolization (UAE), Peripheral Balloon Angioplasty, Stroke Thrombectomy, Internal Iliac Artery Embolization
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| VSI Tru-Torque guidewire The VSI Tru-Torque Steerable Guidewire facilitates placement of a catheter during diagnostic angiography and interventional procedures. The VSI Tru-Torque can be accurately… | Length: 150β300 cm; Outer Diameter: 0.04 in | 9 | Not stated |
| Amplatz SST guidewire The Amplatz SST Steerable Guidewire facilitates placement of a catheter during diagnostic angiography and interventional procedures. The Amplatz SST can be accurately… | Outer Diameter: 0.04 in; Length: 80β260 cm | 7 | Not stated |
| Axis guidewire To facilitate the placement of devices during diagnostic and interventional procedures. | Length: 90β260 cm; Outer Diameter: 0.04 in | 5 | Not stated |
| Bandit guidewire | Length: 200β300 cm | 2 | Not stated |
| Raider guidewire The Raider guidewire is a stainless steel core guidewire with a maximum outer diameter of 0.014β and a straight, shapeable tip. It… | Outer Diameter: 0.01 in; Length: 190β300 cm | 2 | Not stated |
| Warrior guidewire | Length: 190β300 cm; Outer Diameter: 0.01 in | 2 | Not stated |
| VSI .025" Guidewire To facilitate the placement of devices during diagnostic and interventional procedures. | Outer Diameter: 0.03 in; Length: 150 cm | 1 | Not stated |
| VSI Torque Device The VSI Torque Device is intended for use in manipulating a guidewire that is in the vasculature. | β | 1 | Not stated |
| VSI Guidewire | Length: 40 cm; Outer Diameter: 0.02 in | 1 | Not stated |
Microcatheters
Used in: Uterine Artery Embolization (UAE), Prostate Artery Embolization (PAE), Genicular Artery Embolization (GAE), Ovarian Vein Embolization, Varicocele Embolization, Transarterial Chemoembolization (TACE)
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| SuperCross microcatheter | Length: 130 cm; Catheter Gauge: 1.8 Fr | 1 | Not stated |
Radial Compression Devices (TR Band)
Used in: Arterial Access Site Closure (TR Band and Closure Devices)
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| Vasc Band hemostat The Vasc Band hemostat is a compression device to assist hemostasis of arterial, venous and hemodialysis percutaneous access sites. | Length: 21β37 cm | 5 | Not stated |
| Vasc Band inflation syringe | β | 1 | Not stated |
| D-Stat Clamp topical hemostat accessory | β | 1 | Not stated |
Sales representatives
No representatives listed yet. Manufacturers can add their reps by territory.
Product lines, models and sizes are compiled from the FDA Global Unique Device Identification Database (GUDID) and FDA clearance records. Descriptions marked "Provided by the manufacturer" come from the company and are reviewed before publishing.