Angiographic Catheters

Used in: Uterine Artery Embolization (UAE), Internal Iliac Artery Embolization

ProductSizes (FDA GUDID)ModelsMRI
Langston dual lumen catheter
Each LANGSTON dual lumen catheter is indicated for delivery of contrast medium in angiographic studies and for simultaneous pressure measurement from two…
Catheter Gauge: 6–7 Fr4Not stated
Gandras catheters
The GANDRAS catheter is designed to be used for delivering embolic materials and radiopaque media to selected sites in the vascular system.…
Length: 84–86 cm; Catheter Gauge: 5 Fr2Not stated
Gandras catheter
Catheter Gauge: 5 Fr; Length: 82 cm1Not stated
Gandras VISCI-G catheter
The GANDRAS VISCI-G catheter is designed to be used for delivering embolic materials and radiopaque media to selected sites in the vascular…
Catheter Gauge: 5 Fr; Length: 75 cm1Not stated

Embolic Microspheres and Particles (Beads)

Used in: Uterine Artery Embolization (UAE), Prostate Artery Embolization (PAE), Genicular Artery Embolization (GAE), Transarterial Chemoembolization (TACE), Portal Vein Embolization, Middle Meningeal Artery Embolization

ProductSizes (FDA GUDID)ModelsMRI
Gel-Bead Embolization Spheres
β€”10Not stated

Guidewires

Used in: Uterine Artery Embolization (UAE), Peripheral Balloon Angioplasty, Stroke Thrombectomy, Internal Iliac Artery Embolization

ProductSizes (FDA GUDID)ModelsMRI
VSI Tru-Torque guidewire
The VSI Tru-Torque Steerable Guidewire facilitates placement of a catheter during diagnostic angiography and interventional procedures. The VSI Tru-Torque can be accurately…
Length: 150–300 cm; Outer Diameter: 0.04 in9Not stated
Amplatz SST guidewire
The Amplatz SST Steerable Guidewire facilitates placement of a catheter during diagnostic angiography and interventional procedures. The Amplatz SST can be accurately…
Outer Diameter: 0.04 in; Length: 80–260 cm7Not stated
Axis guidewire
To facilitate the placement of devices during diagnostic and interventional procedures.
Length: 90–260 cm; Outer Diameter: 0.04 in5Not stated
Bandit guidewire
Length: 200–300 cm2Not stated
Raider guidewire
The Raider guidewire is a stainless steel core guidewire with a maximum outer diameter of 0.014” and a straight, shapeable tip. It…
Outer Diameter: 0.01 in; Length: 190–300 cm2Not stated
Warrior guidewire
Length: 190–300 cm; Outer Diameter: 0.01 in2Not stated
VSI .025" Guidewire
To facilitate the placement of devices during diagnostic and interventional procedures.
Outer Diameter: 0.03 in; Length: 150 cm1Not stated
VSI Torque Device
The VSI Torque Device is intended for use in manipulating a guidewire that is in the vasculature.
β€”1Not stated
VSI Guidewire
Length: 40 cm; Outer Diameter: 0.02 in1Not stated

Microcatheters

Used in: Uterine Artery Embolization (UAE), Prostate Artery Embolization (PAE), Genicular Artery Embolization (GAE), Ovarian Vein Embolization, Varicocele Embolization, Transarterial Chemoembolization (TACE)

ProductSizes (FDA GUDID)ModelsMRI
SuperCross microcatheter
Length: 130 cm; Catheter Gauge: 1.8 Fr1Not stated

Radial Compression Devices (TR Band)

Used in: Arterial Access Site Closure (TR Band and Closure Devices)

ProductSizes (FDA GUDID)ModelsMRI
Vasc Band hemostat
The Vasc Band hemostat is a compression device to assist hemostasis of arterial, venous and hemodialysis percutaneous access sites.
Length: 21–37 cm5Not stated
Vasc Band inflation syringe
β€”1Not stated
D-Stat Clamp topical hemostat accessory
β€”1Not stated

Sales representatives

Vascular Solutions, Inc. has not listed representatives here yet. Send a request and we will route it to the right person for your country.

Work for Vascular Solutions, Inc.? Add a rep and the areas they cover:

Product lines, models and sizes are compiled from the FDA Global Unique Device Identification Database (GUDID) and FDA clearance records. Descriptions marked "Provided by the manufacturer" come from the company and are reviewed before publishing.

πŸ“¬ The IR Device Brief

One email a month: new FDA clearances, recalls and device pages in vascular & interventional radiology.

We'll email you a link to confirm. Unsubscribe any time.

Suggest edits

For manufacturers and their teams. Each field shows what the page says now: add, remove or rewrite anything, and leave the rest as is. LA Vascular reviews every change before it goes live.

About you