Indigo R Aspiration System Lightning Flash Aspiration Tubing Indigo R Aspiration System Lightning Bolt Aspiration Tubing
Product: Indigo System Lightning Bolt 16 — all models and sizes
FDA Clearance Information
The Indigo R Aspiration System received FDA clearance through the 510k pathway on October 16, 2025. It is manufactured by Penumbra and is classified as a Class 2 medical device.
What It Is
FDA-Cleared Indications
- Mechanical thrombectomy with aspiration for removing thrombus from the peripheral vasculature.
- Use in the peripheral venous system when catheter-based aspiration thrombectomy is clinically appropriate.
Clinical Applications
- Aspiration thrombectomy for selected lower-extremity deep vein thrombosis.
- Aspiration thrombectomy for selected pulmonary embolism involving the pulmonary arteries.
- Aspiration thrombectomy for selected thrombosed dialysis grafts or fistulas when the treated anatomy and device configuration are compatible with the labeling.
Reported off-label uses
- Aspiration thrombectomy in other peripheral venous segments not specifically covered by the device labeling may be reported in clinical practice, but this is off-label and should be evaluated by the treating specialist.
Off-label use: these uses are reported in practice or the literature but are not part of the FDA-cleared indications. Physicians may use a cleared device off-label based on their medical judgment; the manufacturer may not promote off-label uses.
Practical Considerations
- The system includes different aspiration tubing configurations, including Lightning Flash and Lightning Bolt, and the treating physician selects components based on vessel anatomy, clot burden and procedural access.
- The system is used with catheterization techniques under fluoroscopic or other appropriate imaging guidance, generally through venous access such as the femoral or jugular vein.
- Device sizing, aspiration settings and compatibility with the intended catheter and ancillary equipment must be confirmed in the current manufacturer instructions for use.
- MRI safety depends on the specific implanted or retained components; the device is used during a procedure rather than left permanently in the body. MRI conditions should be verified in the current labeling before scanning.
- Contraindications, warnings and bleeding risks must be reviewed in the current FDA-cleared labeling. Mechanical thrombectomy may not be appropriate for every patient, and medication or surgical treatment may also be considered.
Related Literature
Procedures that use this device
Linked Studies (20)
Randomized Controlled Trial of Mechanical Thrombectomy With Anticoagulation Versus Anticoagulation Alone for Acute Intermediate-High Risk Pulmonary Embolism: Primary Outcomes From the STORM-PE Trial.
Circulation
RCT|prospective View Source →A New Technique for Mechanical Thrombectomy in Patients With Acute Pulmonary Embolism: A Case Series.
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Case Series View Source →Rescue catheter directed treatment for floating right atrial thrombi and deep vein thrombosis in patient with high-risk acute pulmonary embolism: a case report of multidisciplinary approach.
European heart journal. Case reports
RCT|prospective|retrospective|case Series|other View Source →Percutaneous vacuum-assisted tumor thrombectomy using angiovac and penumbra lightning 12 aspiration systems.
Radiology case reports
RCT|prospective|retrospective|case Series|other View Source →Safety and efficacy of mechanical aspiration thrombectomy for patients with acute lower extremity ischemia.
Journal of vascular surgery
RCT|prospective|retrospective|case Series|other View Source →Neuro-tracking catheter technology for coronary thrombus extraction: Indigo CAT RX Continuous Aspiration System - first use in Poland.
Postepy w kardiologii interwencyjnej = Advances in interventional cardiology
View Source →[Interventional therapy of pulmonary embolism - update].
Deutsche medizinische Wochenschrift (1946)
RCT|prospective|retrospective|case Series|other View Source →Super-Elderly Case of Acute Lower Limb Ischemia Treated with Indigo Aspiration System in Japan.
Annals of vascular diseases
Case Series View Source →Procedure-Related Mortality in Aspiration Thrombectomy for Pulmonary Embolism: A MAUDE Database Analysis of the Inari FlowTriever and Penumbra Indigo Systems.
Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
RCT|prospective|retrospective|case Series|other View Source →Endovascular thrombectomy for cerebral venous sinus thrombosis using the Penumbra Indigo® Aspiration System.
Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences
RCT|prospective|retrospective|case Series|other View Source →Use of the Indigo CAT RX aspiration system during percutaneous coronary intervention.
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Other View Source →Anesthetic Management for Aspiration Thrombectomy Using the Penumbra Indigo System in Pediatric Patients with Congenital Heart Disease.
Journal of cardiothoracic and vascular anesthesia
Other View Source →Penumbra Indigo® system to safely remove intracardiac thrombus in a 7-month-old infant with severe immunodeficiency disorder.
Cardiology in the young
RCT|prospective|retrospective|case Series|other View Source →Case Report: Catheter-based mechanical thrombectomy using the Indigo aspiration system in a case of systemic-to-pulmonary shunt thrombosis.
Frontiers in pediatrics
Case Report View Source →Mechanical Venous Thrombectomy Using Indigo Aspiration System: A Case Report.
Cureus
View Source →Indigo® Aspiration System for thrombectomy in pulmonary embolism.
Future cardiology
RCT|prospective|retrospective|case Series|other View Source →Penumbra Indigo Percutaneous Aspiration Thrombectomy System in the treatment of Aortic Endograft Iliac Limb Occlusion: Results from an Italian Multicentre Registry.
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery
RCT|prospective|retrospective|case Series|other View Source →Aspiration Thrombectomy with the Indigo System for Acute Lower Limb Ischemia: Preliminary experience and analysis of parameters affecting the outcome.
Annals of vascular surgery
RCT|prospective|retrospective|case Series|other View Source →Complications and Failure Modes of the Penumbra Indigo CAT RX Aspiration System in Percutaneous Coronary Intervention: Insights From the MAUDE Database.
Cardiovascular revascularization medicine : including molecular interventions
View Source →Technical success and short-term results from mechanical thrombectomy for lower extremity iliofemoral deep vein thrombosis using a computer aided mechanical aspiration thrombectomy device.
Journal of vascular surgery. Venous and lymphatic disorders
RCT|prospective|retrospective|case Series|other View Source →Frequently Asked Questions
What is the Indigo R Aspiration System used for?
It is used for mechanical thrombectomy in the venous system, particularly for conditions like deep vein thrombosis and pulmonary embolism.
What specialties typically use this device?
Interventional radiologists and vascular surgeons commonly use this device in hospital settings.
What are the FDA-cleared indications?
The device is indicated for mechanical thrombectomy in venous thromboembolic conditions, such as pulmonary embolism and deep vein thrombosis.