Biliary drains

Biliary Plastic Stent Set/ short-wire compatible

by Micro-Tech (Nanjing) Co., Ltd.

A flexible tube intended for percutaneous placement in the abdomen to establish a channel for temporary or prolonged drainage of an obstructed biliary tract, for splinting of the bile duct during healing, or for preventing stricture of the bile duct. It is distally inserted into the common bile duct, hepatic ducts (transhepatic biliary drainage), or gallbladder (cholecystostomy drainage); disposable devices dedicated to drain introduction may be included with the device. It may be used in conjunction with a low negative pressure system and is available in various designs (e.g., silicone Y- or T-tube, catheter-like, with perforations). This is a single-use device.

Ask about this device Where to buy Compare similar devices

Find similar biliary stents

Where to buy Biliary Plastic Stent Set/ short-wire compatible

We do not have contact details for Micro-Tech (Nanjing) Co., Ltd. yet. Send a request and we will route it to the right person for your country.

Request this device

Is this your product? Claim Micro-Tech (Nanjing) Co., Ltd. to list your reps and distributors by country and receive buyer requests from your territories.

Biliary Plastic Stent Set/ short-wire compatible models and sizes

From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.

Model / catalog no.SizeMRIStatus
RBPDS-41993-0703/17Stent Diameter 2.35 mm; Stent Length 30 mm MR SafeAvailable
RBPDS-41993-0705/17Stent Diameter 2.35 mm; Stent Length 50 mm MR SafeAvailable
RBPDS-41993-0707/17Stent Diameter 2.35 mm; Stent Length 70 mm MR SafeAvailable
RBPDS-41993-0710/17Stent Diameter 2.35 mm; Stent Length 100 mm MR SafeAvailable
RBPDS-41993-0712/17Stent Diameter 2.35 mm; Stent Length 120 mm MR SafeAvailable
RBPDS-41993-0715/17Stent Diameter 2.35 mm; Stent Length 150 mm MR SafeAvailable
RBPDS-41993-0803/22Stent Diameter 2.9 mm; Stent Length 30 mm MR SafeAvailable
RBPDS-41993-0805/22Stent Diameter 2.9 mm; Stent Length 50 mm MR SafeAvailable
RBPDS-41993-0807/22Stent Diameter 2.9 mm; Stent Length 70 mm MR SafeAvailable
RBPDS-41993-0810/22Stent Diameter 2.9 mm; Stent Length 100 mm MR SafeAvailable
RBPDS-41993-0812/22Stent Diameter 2.9 mm; Stent Length 120 mm MR SafeAvailable
RBPDS-41993-0815/22Stent Diameter 2.9 mm; Stent Length 150 mm MR SafeAvailable
RBPDS-41993-1003/22Stent Diameter 3.3 mm; Stent Length 30 mm MR SafeAvailable
RBPDS-41993-1005/22Stent Diameter 3.3 mm; Stent Length 50 mm MR SafeAvailable
RBPDS-41993-1007/22Stent Diameter 3.3 mm; Stent Length 70 mm MR SafeAvailable
RBPDS-41993-1010/22Stent Diameter 3.3 mm; Stent Length 100 mm MR SafeAvailable
RBPDS-41993-1012/22Stent Diameter 3.3 mm; Stent Length 120 mm MR SafeAvailable
RBPDS-41993-1015/22Stent Diameter 3.3 mm; Stent Length 150 mm MR SafeAvailable
RBPDS-43114-0705/17Stent Diameter 2.35 mm; Stent Length 50 mm MR SafeAvailable
RBPDS-43114-0707/17Stent Diameter 2.35 mm; Stent Length 70 mm MR SafeAvailable
RBPDS-43114-0709/17Stent Diameter 2.35 mm; Stent Length 90 mm MR SafeAvailable
RBPDS-43114-0712/17Stent Diameter 2.35 mm; Shaft Length 120 mm MR SafeAvailable
RBPDS-43114-0715/17Stent Diameter 2.35 mm; Stent Length 150 mm MR SafeAvailable
RBPDS-43114-0718/17Stent Diameter 2.35 mm; Stent Length 180 mm MR SafeAvailable
RBPDS-43114-0805/22Stent Diameter 2.9 mm; Stent Length 50 mm MR SafeAvailable
RBPDS-43114-0807/22Stent Diameter 2.9 mm; Shaft Length 70 mm MR SafeAvailable
RBPDS-43114-0809/22Stent Diameter 2.9 mm; Stent Length 90 mm MR SafeAvailable
RBPDS-43114-0812/22Stent Diameter 2.9 mm; Stent Length 120 mm MR SafeAvailable
RBPDS-43114-0815/22Stent Diameter 2.9 mm; Stent Length 150 mm MR SafeAvailable
RBPDS-43114-0818/22Stent Diameter 2.9 mm; Stent Length 180 mm MR SafeAvailable
RBPDS-43114-1005/22Stent Diameter 3.3 mm; Stent Length 50 mm MR SafeAvailable
RBPDS-43114-1007/22Stent Diameter 3.3 mm; Stent Length 70 mm MR SafeAvailable
RBPDS-43114-1009/22Stent Diameter 3.3 mm; Stent Length 90 mm MR SafeAvailable
RBPDS-43114-1012/22Stent Diameter 3.3 mm; Stent Length 120 mm MR SafeAvailable
RBPDS-43114-1015/22Stent Diameter 3.3 mm; Stent Length 150 mm MR SafeAvailable
RBPDS-43114-1018/22Stent Diameter 3.3 mm; Stent Length 180 mm MR SafeAvailable
RBPDS-44114-0705/17Stent Diameter 2.35 mm; Stent Length 50 mm MR SafeAvailable
RBPDS-44114-0707/17Stent Diameter 2.35 mm; Stent Length 70 mm MR SafeAvailable
RBPDS-44114-0709/17Stent Diameter 2.35 mm; Stent Length 90 mm MR SafeAvailable
RBPDS-44114-0712/17Stent Diameter 2.35 mm; Stent Length 120 mm MR SafeAvailable
RBPDS-44114-0715/17Stent Diameter 2.35 mm; Stent Length 150 mm MR SafeAvailable
RBPDS-44114-0718/17Stent Diameter 2.35 mm; Stent Length 180 mm MR SafeAvailable
RBPDS-44114-0805/22Stent Diameter 2.9 mm; Stent Length 50 mm MR SafeAvailable
RBPDS-44114-0807/22Stent Diameter 2.9 mm; Stent Length 70 mm MR SafeAvailable
RBPDS-44114-0809/22Stent Diameter 2.9 mm; Stent Length 90 mm MR SafeAvailable
RBPDS-44114-0812/22Stent Diameter 2.9 mm; Stent Length 120 mm MR SafeAvailable
RBPDS-44114-0815/22Stent Diameter 2.9 mm; Stent Length 150 mm MR SafeAvailable
RBPDS-44114-0818/22Stent Diameter 2.9 mm; Stent Length 180 mm MR SafeAvailable
RBPDS-44114-1005/22Stent Diameter 3.3 mm; Stent Length 50 mm MR SafeAvailable
RBPDS-44114-1007/22Stent Diameter 3.3 mm; Stent Length 70 mm MR SafeAvailable
RBPDS-44114-1009/22Stent Diameter 3.3 mm; Stent Length 90 mm MR SafeAvailable
RBPDS-44114-1012/22Stent Diameter 3.3 mm; Stent Length 120 mm MR SafeAvailable
RBPDS-44114-1015/22Stent Diameter 3.3 mm; Stent Length 150 mm MR SafeAvailable
RBPDS-44114-1018/22Stent Diameter 3.3 mm; Stent Length 180 mm MR SafeAvailable

FDA clearances

  • 510(k) K230127 September 2023

Procedures that use biliary drains

Frequently asked questions

What is Biliary Plastic Stent Set/ short-wire compatible used for?

A flexible tube intended for percutaneous placement in the abdomen to establish a channel for temporary or prolonged drainage of an obstructed biliary tract, for splinting of the bile duct during healing, or for preventing stricture of the bile duct. It is distally inserted into the common bile duct, hepatic ducts (transhepatic biliary drainage), or gallbladder (cholecystostomy drainage); disposable devices dedicated to drain introduction may be included with the device. It may be used in conjunction with a low negative pressure system and is available in various designs (e.g., silicone Y- or T-tube, catheter-like, with perforations). This is a single-use device.

Who makes Biliary Plastic Stent Set/ short-wire compatible?

Biliary Plastic Stent Set/ short-wire compatible is made by Micro-Tech (Nanjing) Co., Ltd.. It is listed under biliary drainage catheters in our device library.

What sizes does Biliary Plastic Stent Set/ short-wire compatible come in?

Sizes listed for Biliary Plastic Stent Set/ short-wire compatible: Stent Diameter: 2.35–3.3 mm; Stent Length: 30–180 mm; Shaft Length: 70–120 mm. Confirm availability with the manufacturer's instructions for use.

Is Biliary Plastic Stent Set/ short-wire compatible MRI safe?

The FDA device database lists Biliary Plastic Stent Set/ short-wire compatible as MR Safe. Always follow the specific MRI conditions in the labeling.

Is Biliary Plastic Stent Set/ short-wire compatible FDA cleared?

Biliary Plastic Stent Set/ short-wire compatible is covered by FDA submission K230127.

How do I contact a Micro-Tech (Nanjing) Co., Ltd. sales representative?

Micro-Tech (Nanjing) Co., Ltd. has not listed representatives on LA Vascular yet. Visit the Micro-Tech (Nanjing) Co., Ltd. company page for contact details.

Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.

πŸ“¬ The IR Device Brief

One email a month: new FDA clearances, recalls and device pages in vascular & interventional radiology.

We'll email you a link to confirm. Unsubscribe any time.

Suggest edits