Micro-Tech (Nanjing) Co., Ltd.
10 product lines across 2 device categories: Biliary drains, Biopsy needles.
Is this your company? Claim this page to add product descriptions, indications, sizes and your sales reps by territory.
Biliary Drainage Catheters
Used in: Percutaneous Biliary Drainage (PTBD)
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| Biliary Plastic Stent TPU,Center bend,7Fr,12cm | Stent Diameter: 2.3β3.8 mm; Stent Length: 30β180 mm; Shaft Length: 70β150 mm | 90 | MR Safe |
| Biliary Plastic Stent Set TPU,Straight,8.5Fr,18cm working length with 2200mm introducer | Stent Diameter: 2.35β3.8 mm; Stent Length: 30β180 mm | 90 | MR Safe |
| Biliary Plastic Stent Set/ short-wire compatible TPU,Side bend,8.5Fr,9cm working length with 2200mm introducer | Stent Diameter: 2.35β3.3 mm; Stent Length: 30β180 mm; Shaft Length: 70β120 mm | 54 | MR Safe |
| Sterile Biliary Stone Retrieval Balloon Catheter Sterile Biliary Stone Retrieval Balloon Catheter with triple-lumen, Work diameter 9mm/12mm/15mm, Working Length 2000mm, | Balloon Diameter: 9β21 mm; Catheter Working Length: 2,000 mm | 28 | Not stated |
| Reliant(TM) Multistage Dilatation Balloon Catheter the balloon diameter is 15-16.5-18mm,the balloon length is 55mm,the catheter diameter is 7 Fr., and the working length is 2300mm,with stainless steel… | Balloon Length: 30β80 mm | 22 | Not stated |
| Dilation Balloon Catheter Working Length 2900mm, Maximum Outer Diameter of Insertion Part less than 1.8mm, Balloon Length 30mm, Balloon OD 8mm, Rated Pressure 6atm, Burst… | Balloon Diameter: 4β8 mm; Balloon Length: 20β40 mm | 9 | Not stated |
| Biliary Plastic Stent Introducer 8.5Fr Introducer diameter,40cm Max length of plastic stent can be introduced,2200mm Working length | Outer Diameter: 2.35β3.8 mm; Length: 170β220 cm | 4 | Not stated |
| Biliary Plastic Stent Introducer/ short-wire compatible 8.5Fr The outside diameter,40cm Max length of Biliary catheter can be introduced,2200mm Working length | Outer Diameter: 2.35β3.3 mm; Length: 1,700β2,200 mm | 3 | Not stated |
Biopsy Needles and Systems
Used in: Image-Guided Needle Biopsy
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| Trident(TM) Endoscopic Ultrasound Biopsy Needle (FNB) Maximum insertion portion diameter:2.3mm,Needle:19G,Maximum needle length:80mm,Working channel: Greater than or equal to 2.8mm,Working Length:1197~1237mm, FNB needle | Needle Gauge: 19β25 G | 9 | Not stated |
| Trident(TM) Adapt Endoscopic Ultrasound Biopsy Needle(FNB) Maximum insertion portion diameter:2.5mm,Needle:19G,Maximum needle length:80mm,Needle structure: Butted needle, Working channel: Greater than or equal to 2.8mm,Working Length:1197~1237mm, FNB needle | Needle Gauge: 19β22 G | 6 | Not stated |
Sales representatives
No representatives listed yet. Manufacturers can add their reps by territory.
Product lines, models and sizes are compiled from the FDA Global Unique Device Identification Database (GUDID) and FDA clearance records. Descriptions marked "Provided by the manufacturer" come from the company and are reviewed before publishing.