Drug-coated balloons

Stellarex

by Philips Image Guided Therapy Corporation

A sterile, flexible tube designed for percutaneous transluminal angioplasty (PTA) to dilate a stenotic peripheral (i.e., non-cerebral, non-coronary) artery by controlled inflation of a distensible balloon(s) at its distal tip, and to simultaneously release a drug intended to inhibit restenosis; it may also be intended for positioning and expansion of a stent/stent-graft. It is available as an over-the-wire (OTW) type with multiple lumens, or a rapid exchange (RX) type with a single-lumen. This is a single-use device.

Contact a rep Compare similar devices

Stellarex models and sizes

From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.

Model / catalog no.SizeMRIStatus
AB35SX040040080Balloon Diameter 4 mm; Balloon Length 40 mm; Catheter Length 80 cm Not statedAvailable
AB35SX040040135Balloon Diameter 4 mm; Balloon Length 40 mm; Catheter Length 135 cm Not statedAvailable
AB35SX040060080Balloon Diameter 4 mm; Balloon Length 60 mm; Catheter Length 80 cm Not statedAvailable
AB35SX040060135Balloon Diameter 4 mm; Balloon Length 60 mm; Catheter Length 135 cm Not statedAvailable
AB35SX040080080Balloon Diameter 4 mm; Balloon Length 80 mm; Catheter Length 80 cm Not statedAvailable
AB35SX040080135Balloon Diameter 4 mm; Balloon Length 80 mm; Catheter Length 135 cm Not statedAvailable
AB35SX040100080Balloon Diameter 4 mm; Balloon Length 100 mm; Catheter Length 80 cm Not statedAvailable
AB35SX040100135Balloon Diameter 4 mm; Balloon Length 100 mm; Catheter Length 135 cm Not statedAvailable
AB35SX040120080Balloon Diameter 4 mm; Balloon Length 120 mm; Catheter Length 80 cm Not statedAvailable
AB35SX040120135Balloon Diameter 4 mm; Balloon Length 120 mm; Catheter Length 135 cm Not statedAvailable
AB35SX040150080Balloon Diameter 4 mm; Balloon Length 150 mm; Catheter Length 80 cm Not statedAvailable
AB35SX040150135Balloon Diameter 4 mm; Balloon Length 150 mm; Catheter Length 135 cm Not statedAvailable
AB35SX040200080Balloon Diameter 4 mm; Balloon Length 200 mm; Catheter Length 80 cm Not statedAvailable
AB35SX040200135Balloon Diameter 4 mm; Balloon Length 200 mm; Catheter Length 135 cm Not statedAvailable
AB35SX050040080Balloon Diameter 5 mm; Balloon Length 40 mm; Catheter Length 80 cm Not statedAvailable
AB35SX050040135Balloon Diameter 5 mm; Balloon Length 40 mm; Catheter Length 135 cm Not statedAvailable
AB35SX050060080Balloon Diameter 5 mm; Balloon Length 60 mm; Catheter Length 80 cm Not statedAvailable
AB35SX050060135Balloon Diameter 5 mm; Balloon Length 60 mm; Catheter Length 135 cm Not statedAvailable
AB35SX050080080Balloon Diameter 5 mm; Balloon Length 80 mm; Catheter Length 80 cm Not statedAvailable
AB35SX050080135Balloon Diameter 5 mm; Balloon Length 80 mm; Catheter Length 135 cm Not statedAvailable
AB35SX050100080Balloon Diameter 5 mm; Balloon Length 100 mm; Catheter Length 80 cm Not statedAvailable
AB35SX050100135Balloon Diameter 5 mm; Balloon Length 100 mm; Catheter Length 135 cm Not statedAvailable
AB35SX050120080Balloon Diameter 5 mm; Balloon Length 120 mm; Catheter Length 80 cm Not statedAvailable
AB35SX050120135Balloon Diameter 5 mm; Balloon Length 120 mm; Catheter Length 135 cm Not statedAvailable
AB35SX050150080Balloon Diameter 5 mm; Balloon Length 150 mm; Catheter Length 80 cm Not statedAvailable
AB35SX050150135Balloon Diameter 5 mm; Balloon Length 150 mm; Catheter Length 135 cm Not statedAvailable
AB35SX050200080Balloon Diameter 5 mm; Balloon Length 200 mm; Catheter Length 80 cm Not statedAvailable
AB35SX050200135Balloon Diameter 5 mm; Balloon Length 200 mm; Catheter Length 135 cm Not statedAvailable
AB35SX060040080Balloon Diameter 6 mm; Balloon Length 40 mm; Catheter Length 80 cm Not statedAvailable
AB35SX060040135Balloon Diameter 6 mm; Balloon Length 40 mm; Catheter Length 135 cm Not statedAvailable
AB35SX060060080Balloon Diameter 6 mm; Balloon Length 60 mm; Catheter Length 80 cm Not statedAvailable
AB35SX060060135Balloon Diameter 6 mm; Balloon Length 60 mm; Catheter Length 135 cm Not statedAvailable
AB35SX060080080Balloon Diameter 6 mm; Balloon Length 80 mm; Catheter Length 80 cm Not statedAvailable
AB35SX060080135Balloon Diameter 6 mm; Balloon Length 80 mm; Catheter Length 135 cm Not statedAvailable
AB35SX060100080Balloon Diameter 6 mm; Balloon Length 100 mm; Catheter Length 80 cm Not statedAvailable
AB35SX060100135Balloon Diameter 6 mm; Balloon Length 100 mm; Catheter Length 135 cm Not statedAvailable
AB35SX060120080Balloon Diameter 6 mm; Balloon Length 120 mm; Catheter Length 80 cm Not statedAvailable
AB35SX060120135Balloon Diameter 6 mm; Balloon Length 120 mm; Catheter Length 135 cm Not statedAvailable
AB35SX060150080Balloon Diameter 6 mm; Balloon Length 150 mm; Catheter Length 80 cm Not statedAvailable
AB35SX060150135Balloon Diameter 6 mm; Balloon Length 150 mm; Catheter Length 135 cm Not statedAvailable
AB35SX060200080Balloon Diameter 6 mm; Balloon Length 200 mm; Catheter Length 80 cm Not statedAvailable
AB35SX060200135Balloon Diameter 6 mm; Balloon Length 200 mm; Catheter Length 135 cm Not statedAvailable

FDA clearances

Procedures that use drug-coated balloons

Frequently asked questions

What is Stellarex used for?

A sterile, flexible tube designed for percutaneous transluminal angioplasty (PTA) to dilate a stenotic peripheral (i.e., non-cerebral, non-coronary) artery by controlled inflation of a distensible balloon(s) at its distal tip, and to simultaneously release a drug intended to inhibit restenosis; it may also be intended for positioning and expansion of a stent/stent-graft. It is available as an over-the-wire (OTW) type with multiple lumens, or a rapid exchange (RX) type with a single-lumen. This is a single-use device.

Who makes Stellarex?

Stellarex is made by Philips Image Guided Therapy Corporation. It is listed under drug-coated balloons in our device library.

What sizes does Stellarex come in?

Sizes listed for Stellarex: Balloon Diameter: 4–6 mm; Balloon Length: 40–200 mm; Catheter Length: 80–135 cm. Confirm availability with the manufacturer's instructions for use.

Is Stellarex MRI safe?

The FDA device database entry for Stellarex does not state its MRI safety status. Check the labeling before MRI.

Is Stellarex FDA cleared?

Stellarex is covered by FDA submission P160049.

How do I contact a Philips Image Guided Therapy Corporation sales representative?

Philips Image Guided Therapy Corporation has not listed representatives on LA Vascular yet. Visit the Philips Image Guided Therapy Corporation company page for contact details.

Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.

📬 The IR Device Brief

One email a month: new FDA clearances, recalls and device pages in vascular & interventional radiology.

We'll email you a link to confirm. Unsubscribe any time.

Suggest edits

For manufacturers and their teams. Each field shows what the page says now: add, remove or rewrite anything, and leave the rest as is. LA Vascular reviews every change before it goes live.

About you