GORE EXCLUDER AAA Endoprosthesis with C3 Delivery
by W. L. Gore & Associates, Inc.
A non-bioabsorbable tubular device typically implanted at the junction of the abdominal aorta and the common iliac arteries to reduce pressure on an abdominal aortic aneurysm (AAA) [includes aortoiliac aneurysm]; it does not contain anticoagulants or pharmaceuticals. It is percutaneously inserted via the femoral artery to the site of implantation where it self-expands. It is made of a metallic mesh structure with a polymer tube (endovascular graft) and is typically available as a: 1) single tube for insertion into the aorta and/or one iliac artery; or 2) two-part bifurcation design (e.g., Y-shaped tube) for insertion through both iliac arteries.
GORE EXCLUDER AAA Endoprosthesis with C3 Delivery models and sizes
From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.
| Model / catalog no. | Size | MRI | Status |
|---|---|---|---|
| RLT231212 | Outer Diameter 12 mm; Outer Diameter 23 mm; Length 12 cm | MR Conditional | Available |
| RLT231214 | Length 14 cm; Outer Diameter 23 mm; Outer Diameter 12 mm | MR Conditional | Available |
| RLT231216 | Outer Diameter 12 mm; Outer Diameter 23 mm; Length 16 cm | MR Conditional | Available |
| RLT231218 | Length 18 cm; Outer Diameter 23 mm; Outer Diameter 12 mm | MR Conditional | Available |
| RLT231412 | Outer Diameter 14.5 mm; Outer Diameter 23 mm; Length 12 cm | MR Conditional | Available |
| RLT231414 | Length 14 cm; Outer Diameter 23 mm; Outer Diameter 14.5 mm | MR Conditional | Available |
| RLT231416 | Outer Diameter 14.5 mm; Outer Diameter 23 mm; Length 16 cm | MR Conditional | Available |
| RLT231418 | Length 18 cm; Outer Diameter 23 mm; Outer Diameter 14.5 mm | MR Conditional | Available |
| RLT261212 | Outer Diameter 12 mm; Outer Diameter 26 mm; Length 12 cm | MR Conditional | Available |
| RLT261214 | Length 14 cm; Outer Diameter 26 mm; Outer Diameter 12 mm | MR Conditional | Available |
| RLT261216 | Outer Diameter 12 mm; Outer Diameter 26 mm; Length 16 cm | MR Conditional | Available |
| RLT261218 | Length 18 cm; Outer Diameter 26 mm; Outer Diameter 12 mm | MR Conditional | Available |
| RLT261412 | Outer Diameter 14.5 mm; Outer Diameter 26 mm; Length 12 cm | MR Conditional | Available |
| RLT261414 | Length 14 cm; Outer Diameter 26 mm; Outer Diameter 14.5 mm | MR Conditional | Available |
| RLT261416 | Outer Diameter 14.5 mm; Outer Diameter 26 mm; Length 16 cm | MR Conditional | Available |
| RLT261418 | Length 18 cm; Outer Diameter 26 mm; Outer Diameter 14.5 mm | MR Conditional | Available |
| RLT281212 | Outer Diameter 12 mm; Outer Diameter 28.5 mm; Length 12 cm | MR Conditional | Available |
| RLT281214 | Length 14 cm; Outer Diameter 28.5 mm; Outer Diameter 12 mm | MR Conditional | Available |
| RLT281218 | Length 18 cm; Outer Diameter 28.5 mm; Outer Diameter 12 mm | MR Conditional | Available |
| RLT281412 | Outer Diameter 14.5 mm; Outer Diameter 28.5 mm; Length 12 cm | MR Conditional | Available |
| RLT281414 | Length 14 cm; Outer Diameter 28.5 mm; Outer Diameter 14.5 mm | MR Conditional | Available |
| RLT281416 | Outer Diameter 14.5 mm; Outer Diameter 28.5 mm; Length 16 cm | MR Conditional | Available |
| RLT281418 | Length 18 cm; Outer Diameter 28.5 mm; Outer Diameter 14.5 mm | MR Conditional | Available |
| RLT311413 | Outer Diameter 31 mm; Outer Diameter 14.5 mm; Length 13 cm | MR Conditional | Available |
| RLT311415 | Length 15 cm; Outer Diameter 14.5 mm; Outer Diameter 31 mm | MR Conditional | Available |
| RLT311417 | Outer Diameter 31 mm; Outer Diameter 14.5 mm; Length 17 cm | MR Conditional | Available |
| RLT351414 | Length 14 cm; Outer Diameter 14.5 mm; Outer Diameter 35 mm | MR Conditional | Available |
| RLT351416 | Outer Diameter 35 mm; Outer Diameter 14.5 mm; Length 16 cm | MR Conditional | Available |
| RLT351418 | Length 18 cm; Outer Diameter 14.5 mm; Outer Diameter 35 mm | MR Conditional | Available |
| RMT231212 | Outer Diameter 23 mm; Outer Diameter 12 mm; Length 12 cm | MR Conditional | Available |
| RMT231214 | Length 14 cm; Outer Diameter 12 mm; Outer Diameter 23 mm | MR Conditional | Available |
| RMT231216 | Outer Diameter 23 mm; Outer Diameter 12 mm; Length 16 cm | MR Conditional | Available |
| RMT231412 | Outer Diameter 23 mm; Outer Diameter 14.5 mm; Length 12 cm | MR Conditional | Available |
| RMT231414 | Length 14 cm; Outer Diameter 14.5 mm; Outer Diameter 23 mm | MR Conditional | Available |
| RMT231416 | Outer Diameter 23 mm; Outer Diameter 14.5 mm; Length 16 cm | MR Conditional | Available |
| RMT231418 | Length 18 cm; Outer Diameter 14.5 mm; Outer Diameter 23 mm | MR Conditional | Available |
| RMT261212 | Outer Diameter 26 mm; Outer Diameter 12 mm; Length 12 cm | MR Conditional | Available |
| RMT261214 | Length 14 cm; Outer Diameter 12 mm; Outer Diameter 26 mm | MR Conditional | Available |
| RMT261216 | Outer Diameter 26 mm; Outer Diameter 12 mm; Length 16 cm | MR Conditional | Available |
| RMT261218 | Length 18 cm; Outer Diameter 12 mm; Outer Diameter 26 mm | MR Conditional | Available |
| RMT261412 | Outer Diameter 26 mm; Outer Diameter 14.5 mm; Length 12 cm | MR Conditional | Available |
| RMT261414 | Length 14 cm; Outer Diameter 14.5 mm; Outer Diameter 26 mm | MR Conditional | Available |
| RMT261416 | Outer Diameter 26 mm; Outer Diameter 14.5 mm; Length 16 cm | MR Conditional | Available |
| RMT261418 | Length 18 cm; Outer Diameter 14.5 mm; Outer Diameter 26 mm | MR Conditional | Available |
| RMT281212 | Outer Diameter 28.5 mm; Outer Diameter 12 mm; Length 12 cm | MR Conditional | Available |
| RMT281214 | Length 14 cm; Outer Diameter 12 mm; Outer Diameter 28.5 mm | MR Conditional | Available |
| RMT281216 | Outer Diameter 28.5 mm; Outer Diameter 12 mm; Length 16 cm | MR Conditional | Available |
| RMT281218 | Length 18 cm; Outer Diameter 12 mm; Outer Diameter 28.5 mm | MR Conditional | Available |
| RMT281412 | Outer Diameter 28.5 mm; Outer Diameter 14.5 mm; Length 12 cm | MR Conditional | Available |
| RMT281414 | Length 14 cm; Outer Diameter 14.5 mm; Outer Diameter 28.5 mm | MR Conditional | Available |
| RMT281416 | Outer Diameter 28.5 mm; Outer Diameter 14.5 mm; Length 16 cm | MR Conditional | Available |
| RMT281418 | Length 18 cm; Outer Diameter 14.5 mm; Outer Diameter 28.5 mm | MR Conditional | Available |
| RMT311413 | Outer Diameter 31 mm; Outer Diameter 14.5 mm; Length 13 cm | MR Conditional | Available |
| RMT311415 | Length 15 cm; Outer Diameter 14.5 mm; Outer Diameter 31 mm | MR Conditional | Available |
| RMT311417 | Outer Diameter 31 mm; Outer Diameter 14.5 mm; Length 17 cm; Height .5 mm | MR Conditional | Available |
FDA clearances
- PMA P020004 September 2006
Procedures that use aortic stent grafts
Frequently asked questions
What is GORE EXCLUDER AAA Endoprosthesis with C3 Delivery used for?
A non-bioabsorbable tubular device typically implanted at the junction of the abdominal aorta and the common iliac arteries to reduce pressure on an abdominal aortic aneurysm (AAA) [includes aortoiliac aneurysm]; it does not contain anticoagulants or pharmaceuticals. It is percutaneously inserted via the femoral artery to the site of implantation where it self-expands. It is made of a metallic mesh structure with a polymer tube (endovascular graft) and is typically available as a: 1) single tube for insertion into the aorta and/or one iliac artery; or 2) two-part bifurcation design (e.g., Y-shaped tube) for insertion through both iliac arteries.
Who makes GORE EXCLUDER AAA Endoprosthesis with C3 Delivery?
GORE EXCLUDER AAA Endoprosthesis with C3 Delivery is made by W. L. Gore & Associates, Inc.. It is listed under aortic stent grafts (evar/tevar) in our device library.
What sizes does GORE EXCLUDER AAA Endoprosthesis with C3 Delivery come in?
Sizes listed for GORE EXCLUDER AAA Endoprosthesis with C3 Delivery: Outer Diameter: 12–35 mm; Length: 12–18 cm; Height: 0.5 mm. Confirm availability with the manufacturer's instructions for use.
Is GORE EXCLUDER AAA Endoprosthesis with C3 Delivery MRI safe?
The FDA device database lists GORE EXCLUDER AAA Endoprosthesis with C3 Delivery as MR Conditional. Always follow the specific MRI conditions in the labeling.
Is GORE EXCLUDER AAA Endoprosthesis with C3 Delivery FDA cleared?
GORE EXCLUDER AAA Endoprosthesis with C3 Delivery is covered by FDA submission P020004.
How do I contact a W. L. Gore & Associates, Inc. sales representative?
W. L. Gore & Associates, Inc. has not listed representatives on LA Vascular yet. Visit the W. L. Gore & Associates, Inc. company page for contact details.
Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.