Dialysis access
GORE VIABAHN Endoprosthesis
by W. L. Gore & Associates, Inc.
A non-bioabsorbable tubular device intended to be implanted in a peripheral artery (excludes aorta, coronary, pulmonary, and intracranial arteries) to maintain patency and improve luminal diameter, typically in patients with symptomatic peripheral vascular disease or following the recanalization of a total occlusion. It may be intended for implantation in an artery adjacent to the aorta (e.g., iliac, renal), however it is not a dedicated component of an aortoiliac stent-graft assembly; it may additionally be intended for venous implantation. It is a metallic mesh-like structure with a synthetic polymer tube (endovascular graft); it does not include pharmaceuticals.
GORE VIABAHN Endoprosthesis models and sizes
From the FDA Global Unique Device Identification Database. Confirm with the manufacturer's instructions for use.
| Model / catalog no. | Size | MRI | Status |
|---|---|---|---|
| VBC050202 | Catheter Gauge 7 Fr; Length 2.5 cm; Lumen/Inner Diameter 5 mm | MR Conditional | Available |
| VBC050502 | Catheter Gauge 7 Fr; Length 5 cm; Lumen/Inner Diameter 5 mm | MR Conditional | Available |
| VBC051002 | Lumen/Inner Diameter 5 mm; Length 10 cm; Catheter Gauge 7 Fr | MR Conditional | Available |
| VBC051502 | Catheter Gauge 7 Fr; Length 15 cm; Lumen/Inner Diameter 5 mm | MR Conditional | Available |
| VBC060202 | Lumen/Inner Diameter 6 mm; Length 2.5 cm; Catheter Gauge 7 Fr | MR Conditional | Available |
| VBC060501 | Lumen/Inner Diameter 6 mm; Length 5 cm; Catheter Gauge 7 Fr | MR Conditional | Available |
| VBC060502 | Length 5 cm; Lumen/Inner Diameter 6 mm | MR Conditional | Available |
| VBC061001 | Lumen/Inner Diameter 6 mm; Length 10 cm | MR Conditional | Available |
| VBC061002 | Length 10 cm; Lumen/Inner Diameter 6 mm | MR Conditional | Available |
| VBC061501 | Lumen/Inner Diameter 6 mm; Length 15 cm | MR Conditional | Available |
| VBC061502 | Length 15 cm; Lumen/Inner Diameter 6 mm | MR Conditional | Available |
| VBC070202 | Lumen/Inner Diameter 2.5 mm; Length 15 cm | MR Conditional | Available |
| VBC070501 | Length 5 cm; Lumen/Inner Diameter 7 mm | MR Conditional | Available |
| VBC070502 | Lumen/Inner Diameter 7 mm; Length 5 cm | MR Conditional | Available |
| VBC071001 | Length 10 cm; Lumen/Inner Diameter 7 mm | MR Conditional | Available |
| VBC071002 | Lumen/Inner Diameter 7 mm; Length 10 cm | MR Conditional | Available |
| VBC071501 | Length 15 cm; Lumen/Inner Diameter 7 mm | MR Conditional | Available |
| VBC071502 | Lumen/Inner Diameter 7 mm; Length 15 cm | MR Conditional | Available |
| VBC080202 | Length 2.5 cm; Lumen/Inner Diameter 8 mm | MR Conditional | Available |
| VBC080501 | Lumen/Inner Diameter 8 mm; Length 5 cm | MR Conditional | Available |
| VBC080502 | Length 5 cm; Lumen/Inner Diameter 8 mm | MR Conditional | Available |
| VBC081001 | Lumen/Inner Diameter 8 mm; Length 10 cm | MR Conditional | Available |
| VBC081002 | Length 10 cm; Lumen/Inner Diameter 8 mm | MR Conditional | Available |
| VBC081501 | Lumen/Inner Diameter 8 mm; Length 15 cm | MR Conditional | Available |
| VBC081502 | Length 15 cm; Lumen/Inner Diameter 8 mm | MR Conditional | Available |
| VBC090502 | Lumen/Inner Diameter 9 mm; Length 5 cm | MR Conditional | Available |
| VBC090502A | Length 5 cm; Lumen/Inner Diameter 9 mm | MR Conditional | Available |
| VBC091002 | Length 10 cm; Lumen/Inner Diameter 9 mm | MR Conditional | Available |
| VBC091002A | Outer Diameter 9 mm; Length 10 cm | MR Conditional | Available |
| VBC091502 | Lumen/Inner Diameter 9 mm; Length 15 cm | MR Conditional | Available |
| VBC091502A | Length 15 cm; Outer Diameter 9 mm | MR Conditional | Available |
| VBC100202 | Length 2.5 cm; Lumen/Inner Diameter 10 mm | MR Conditional | Available |
| VBC100202A | Lumen/Inner Diameter 10 mm; Length 2.5 cm | MR Conditional | Available |
| VBC100502 | Lumen/Inner Diameter 10 mm; Length 5 cm | MR Conditional | Available |
| VBC100502A | Length 5 cm; Lumen/Inner Diameter 10 mm | MR Conditional | Available |
| VBC101002 | Length 10 cm; Lumen/Inner Diameter 10 mm | MR Conditional | Available |
| VBC101002A | Lumen/Inner Diameter 10 mm; Length 10 cm | MR Conditional | Available |
| VBC101502 | Lumen/Inner Diameter 10 mm; Length 15 cm | MR Conditional | Available |
| VBC101502A | Length 15 cm; Outer Diameter 10 mm | MR Conditional | Available |
| VBC110202 | Length 2.5 cm; Lumen/Inner Diameter 11 mm | MR Conditional | Available |
| VBC110202A | Outer Diameter 11 mm; Length 2.5 cm | MR Conditional | Available |
| VBC110502 | Lumen/Inner Diameter 11 mm; Length 5 cm | MR Conditional | Available |
| VBC110502A | Length 5 cm; Lumen/Inner Diameter 11 mm | MR Conditional | Available |
| VBC111002 | Length 10 cm; Lumen/Inner Diameter 11 mm | MR Conditional | Available |
| VBC111002A | Outer Diameter 11 mm; Length 10 cm | MR Conditional | Available |
| VBC130202 | Lumen/Inner Diameter 13 mm; Length 2.5 cm | MR Conditional | Available |
| VBC130202A | Length 2.5 cm; Lumen/Inner Diameter 13 mm | MR Conditional | Available |
| VBC130502 | Length 2.5 cm; Lumen/Inner Diameter 13 mm | MR Conditional | Available |
| VBC130502A | Length 5 cm; Lumen/Inner Diameter 13 mm | MR Conditional | Available |
| VBC131002 | Lumen/Inner Diameter 13 mm; Length 10 cm | MR Conditional | Available |
| VBC131002A | Outer Diameter 13 mm; Length 10 cm | MR Conditional | Available |
| VBCR050202A | Length 2.5 cm; Lumen/Inner Diameter 5 mm | MR Conditional | Available |
| VBCR050502A | Lumen/Inner Diameter 5 mm; Length 5 cm | MR Conditional | Available |
| VBCR051002A | Length 10 cm; Lumen/Inner Diameter 5 mm | MR Conditional | Available |
| VBCR051502A | Lumen/Inner Diameter 5 mm; Length 15 cm | MR Conditional | Available |
| VBCR060202A | Length 2.5 cm; Lumen/Inner Diameter 6 mm | MR Conditional | Available |
| VBCR060501A | Lumen/Inner Diameter 6 mm; Length 5 cm | MR Conditional | Available |
| VBCR060502A | Length 5 cm; Lumen/Inner Diameter 6 mm | MR Conditional | Available |
| VBCR061001A | Lumen/Inner Diameter 6 mm; Length 10 cm | MR Conditional | Available |
| VBCR061002A | Length 10 cm; Lumen/Inner Diameter 6 mm | MR Conditional | Available |
| VBCR061501A | Lumen/Inner Diameter 6 mm; Length 15 cm | MR Conditional | Available |
| VBCR061502A | Length 15 cm; Lumen/Inner Diameter 6 mm | MR Conditional | Available |
| VBCR070202A | Lumen/Inner Diameter 7 mm; Length 2.5 cm | MR Conditional | Available |
| VBCR070501A | Length 5 cm; Lumen/Inner Diameter 7 mm | MR Conditional | Available |
| VBCR070502A | Lumen/Inner Diameter 7 mm; Length 5 cm | MR Conditional | Available |
| VBCR071001A | Length 10 cm; Outer Diameter 7 mm | MR Conditional | Available |
| VBCR071002A | Lumen/Inner Diameter 7 mm; Length 10 cm | MR Conditional | Available |
| VBCR071501A | Length 15 cm; Outer Diameter 7 mm | MR Conditional | Available |
| VBCR071502A | Lumen/Inner Diameter 7 mm; Length 15 cm | MR Conditional | Available |
| VBCR080202A | Length 2.5 cm; Lumen/Inner Diameter 8 mm | MR Conditional | Available |
| VBCR080501A | Outer Diameter 8 mm; Length 5 cm | MR Conditional | Available |
| VBCR080502A | Length 5 cm; Lumen/Inner Diameter 8 mm | MR Conditional | Available |
| VBCR081001A | Lumen/Inner Diameter 8 mm; Length 10 cm | MR Conditional | Available |
| VBCR081002A | Length 10 cm; Lumen/Inner Diameter 8 mm | MR Conditional | Available |
| VBCR081501A | Lumen/Inner Diameter 8 mm; Length 15 cm | MR Conditional | Available |
| VBCR081502A | Length 15 cm; Outer Diameter 8 mm | MR Conditional | Available |
| VBCR090502A | Catheter Working Length 120 cm; Catheter Gauge 8 Fr; Length 5 cm; Lumen/Inner Diameter 9 mm | MR Conditional | Available |
| VBCR091002A | Lumen/Inner Diameter 9 mm; Length 10 cm; Catheter Gauge 8 Fr; Catheter Working Length 120 cm | MR Conditional | Available |
| VBCR091502A | Lumen/Inner Diameter 9 mm; Length 15 cm; Catheter Gauge 8 Fr; Catheter Working Length 120 cm | MR Conditional | Available |
| VBCR100502A | Lumen/Inner Diameter 10 mm; Length 5 cm; Catheter Gauge 8 Fr; Catheter Working Length 120 cm | MR Conditional | Available |
| VBCR101002A | Catheter Working Length 120 cm; Catheter Gauge 8 Fr; Length 10 cm; Lumen/Inner Diameter 10 mm | MR Conditional | Available |
| VBCR101502A | Lumen/Inner Diameter 10 mm; Length 15 cm; Catheter Gauge 8 Fr; Catheter Working Length 120 cm | MR Conditional | Available |
| VBCR110502A | Catheter Working Length 120 cm; Catheter Gauge 10 Fr; Length 5 cm; Lumen/Inner Diameter 11 mm | MR Conditional | Available |
| VBCR111002A | Lumen/Inner Diameter 11 mm; Length 10 cm; Catheter Gauge 10 Fr; Catheter Working Length 120 cm | MR Conditional | Available |
| VBCR130502A | Lumen/Inner Diameter 13 mm; Length 5 cm; Catheter Gauge 10 Fr; Catheter Working Length 120 cm | MR Conditional | Available |
| VBCR131002A | Catheter Working Length 120 cm; Catheter Gauge 10 Fr; Length 10 cm; Lumen/Inner Diameter 13 mm | MR Conditional | Available |
FDA clearances
- PMA P040037 May 2019
- PMA P130006 April 2014
Procedures that use dialysis access
Frequently asked questions
What is GORE VIABAHN Endoprosthesis used for?
A non-bioabsorbable tubular device intended to be implanted in a peripheral artery (excludes aorta, coronary, pulmonary, and intracranial arteries) to maintain patency and improve luminal diameter, typically in patients with symptomatic peripheral vascular disease or following the recanalization of a total occlusion. It may be intended for implantation in an artery adjacent to the aorta (e.g., iliac, renal), however it is not a dedicated component of an aortoiliac stent-graft assembly; it may additionally be intended for venous implantation. It is a metallic mesh-like structure with a synthetic polymer tube (endovascular graft); it does not include pharmaceuticals.
Who makes GORE VIABAHN Endoprosthesis?
GORE VIABAHN Endoprosthesis is made by W. L. Gore & Associates, Inc.. It is listed under dialysis access devices, peripheral artery stents and covered stents in our device library.
What sizes does GORE VIABAHN Endoprosthesis come in?
Sizes listed for GORE VIABAHN Endoprosthesis: Length: 2.5–15 cm; Lumen/Inner Diameter: 2.5–13 mm; Catheter Gauge: 7–10 Fr. Confirm availability with the manufacturer's instructions for use.
Is GORE VIABAHN Endoprosthesis MRI safe?
The FDA device database lists GORE VIABAHN Endoprosthesis as MR Conditional. Always follow the specific MRI conditions in the labeling.
Is GORE VIABAHN Endoprosthesis FDA cleared?
GORE VIABAHN Endoprosthesis is covered by FDA submissions P040037, P130006.
How do I contact a W. L. Gore & Associates, Inc. sales representative?
W. L. Gore & Associates, Inc. has not listed representatives on LA Vascular yet. Visit the W. L. Gore & Associates, Inc. company page for contact details.
Models, sizes and MRI status come from the FDA Global Unique Device Identification Database (GUDID); descriptions marked "provided by the manufacturer" are reviewed before publishing. Not an endorsement; follow the manufacturer's instructions for use.