Inari Medical, Inc.
29 product lines across 2 device categories: Thrombectomy devices, PE devices.
Is this your company? Claim this page to add product descriptions, indications, sizes and your sales reps by territory.
Mechanical Thrombectomy Devices
Used in: DVT Mechanical Thrombectomy, Pulmonary Embolism Thrombectomy, Dialysis Graft and Fistula Thrombectomy
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| ClotTriever Sheath, 16 Fr ClotTriever Sheath, 16 Fr, 15 cm length | Catheter Gauge: 13–16 Fr; Catheter Working Length: 15 cm; Outer Diameter: 4.6 mm | 4 | Not stated |
| Artix AX Artix™ AX | Length: 85–115 cm | 2 | Not stated |
| Artix MT Artix™ MT | — | 2 | Not stated |
| ClotTriever Catheter ClotTriever Catheter, 16 mm, 105 cm | Outer Diameter: 16 mm; Length: 105 cm | 1 | Not stated |
| InThrill Thrombectomy Catheter | — | 1 | Not stated |
| RevCore Thrombectomy Catheter RevCore Thrombectomy Catheter (Thrombectomy Catheter) | — | 1 | Not stated |
| Triever 24 Triever24 Catheter, 24 Fr, 90 cm, Gen4 | Outer Diameter: 7.6 mm; Catheter Working Length: 90 cm | 1 | Not stated |
| FlowTriever Catheter, Large FlowTriever Catheter, 18 mm | Outer Diameter: 18 mm | 1 | Not stated |
| FlowTriever Catheter, M FlowTriever Catheter, 14 mm | Outer Diameter: 14 mm | 1 | Not stated |
| ClotTriever BOLD Catheter | — | 1 | Not stated |
| ClotTriever XL Catheter | — | 1 | Not stated |
| FlowTriever Catheter, S | Outer Diameter: 10 mm | 1 | Not stated |
| Triever 20 Curve Triever 20 Catheter, 20 Fr, 105 cm | Outer Diameter: 6.5 mm; Catheter Working Length: 105 cm | 1 | Not stated |
| Triever20 | Outer Diameter: 6.7 mm | 1 | Not stated |
| Large Bore Syringe Large Bore 60 cc Syringe | — | 1 | Not stated |
| Triever20 Curve | — | 1 | Not stated |
| VenaCore Thrombectomy Catheter | — | 1 | Not stated |
| InThrill Sheath InThrill Sheath (AS-01403) | — | 1 | Not stated |
| FlowTriever 2 Catheter, M FlorTriever 2 Catheter, Medium, 12Fr, 120 cm | Outer Diameter: 4 mm; Length: 120 cm | 1 | Not stated |
| Triever24 | — | 1 | Not stated |
| FlowTriever Catheter, XL FlowTriever Catheter, 25 mm | Outer Diameter: 14–25 mm | 1 | Not stated |
| Triever16 Curve Triever16 Curve (FlowTriever Retrieval/Aspiration System) | — | 1 | Not stated |
| Protrieve Sheath Protrieve™ Sheath (Sheath) | — | 1 | Not stated |
Pulmonary Embolism Devices
Used in: Pulmonary Embolism Thrombectomy
| Product | Sizes (FDA GUDID) | Models | MRI |
|---|---|---|---|
| FlowTriever Catheter, Large FlowTriever Catheter, 18 mm | Outer Diameter: 18 mm | 1 | Not stated |
| FlowTriever Catheter, M FlowTriever Catheter, 14 mm | Outer Diameter: 14 mm | 1 | Not stated |
| FlowTriever Catheter, S | Outer Diameter: 10 mm | 1 | Not stated |
| FlowTriever 2 Catheter, M FlorTriever 2 Catheter, Medium, 12Fr, 120 cm | Outer Diameter: 4 mm; Length: 120 cm | 1 | Not stated |
| FlowTriever Catheter, XL FlowTriever Catheter, 25 mm | Outer Diameter: 14–25 mm | 1 | Not stated |
| Triever16 Curve Triever16 Curve (FlowTriever Retrieval/Aspiration System) | — | 1 | Not stated |
Sales representatives
No representatives listed yet. Manufacturers can add their reps by territory.
FDA clearances and approvals
- clottriever bold catheter 510K K230494, 2023
- mini-clottriever thrombectomy system 510K K220887, 2022
Product lines, models and sizes are compiled from the FDA Global Unique Device Identification Database (GUDID) and FDA clearance records. Descriptions marked "Provided by the manufacturer" come from the company and are reviewed before publishing.