EverCross
by EV3, Inc · 420 matching models
Wire 0.035" · 3–12 mm diameter · 20–200 mm long · 40–135 cm shaft · sheath 5–7 Fr
Device Finder
Find angioplasty balloons by diameter, length, shaft length and guidewire, and by compliance, pressure, drug coating and arterial or venous use.
25 product lines · 0.035" guidewire compatibility
by EV3, Inc · 420 matching models
Wire 0.035" · 3–12 mm diameter · 20–200 mm long · 40–135 cm shaft · sheath 5–7 Fr
by Bard Peripheral Vascular, Inc. · 361 matching models
Wire 0.035" · 3–12 mm diameter · 10–300 mm long · 40–150 cm shaft
by Lutonix, Inc. · 197 matching models
Wire 0.035" · 4–12 mm diameter · 40–220 mm long · 40–130 cm shaft · sheath 5 Fr
by Cordis US Corp. · 174 matching models
Wire 0.035" · 3–12 mm diameter · 20–300 mm long · 40–135 cm shaft
by Natec Medical Ltd · 168 matching models
Wire 0.035" · 3–12 mm diameter · 20–200 mm long · 80–150 cm shaft
by Natec Medical Ltd · 164 matching models
Wire 0.035" · 3–12 mm diameter · 20–200 mm long · 40–135 cm shaft
by Natec Medical Ltd · 164 matching models
Wire 0.035" · 3–12 mm diameter · 20–200 mm long · 40–135 cm shaft
by Kaneka Corporation · 162 matching models
Wire 0.035" · sheath 5–7 Fr
by Covidien LP · 140 matching models
Wire 0.035" · 3–12 mm diameter · 20–200 mm long · 40–80 cm shaft · sheath 5–7 Fr
by Medtronic, Inc. · 140 matching models
Wire 0.035" · 3–12 mm diameter · 20–200 mm long · 40–135 cm shaft · sheath 5–7 Fr
by Arravasc Limited · 106 matching models
Wire 0.035" · 3–100 mm diameter · 20–200 mm long
by Natec Medical Ltd · 105 matching models
Wire 0.035" · 4–12 mm diameter · 20–100 mm long · 50–135 cm shaft
by Natec Medical Ltd · 80 matching models
Wire 0.035" · 5–10 mm diameter · 20–200 mm long · 80–130 cm shaft
by Lutonix, Inc. · 76 matching models
Wire 0.035" · 4–12 mm diameter · 20–100 mm long · 40–100 cm shaft
by Covidien LP · 74 matching models
Wire 0.035" · 4–12 mm diameter · 40–135 cm shaft · sheath 6–7 Fr
by Nexstep Medical · 48 matching models
Wire 0.035" · 4–10 mm diameter · 20–400 mm long · 12–120 cm shaft · sheath 6–7 Fr
by Kaneka Corporation · 44 matching models
Wire 0.035" · sheath 6 Fr
by Philips Image Guided Therapy Corporation · 42 matching models
Wire 0.035" · 4–6 mm diameter · 40–200 mm long · 80–135 cm shaft
by Spectranetics Corporation · 42 matching models
Wire 0.035" · 4–6 mm diameter · 40–200 mm long · 80–135 cm shaft
by Philips Image Guided Therapy Corporation · 42 matching models
Wire 0.035" · 4–6 mm diameter · 40–200 mm long · 80–135 cm shaft
by BrosMed Medical Co.,Ltd. · 28 matching models
Wire 0.035"
by Natec Medical Ltd · 10 matching models
Wire 0.035" · 5–6 mm diameter · 40–200 mm long · 80 cm shaft
by AV Medical Technologies Ltd · 7 matching models
Wire 0.035" · 5–12 mm diameter · 40 mm long · 75 cm shaft · sheath 5.9–7 Fr
by Verge Medical, Inc. · 3 matching models
Wire 0.035" · 6–7 mm diameter · 12–17 mm long · 135 cm shaft
by BrosMed Medical Co.,Ltd. · 1 matching model
Wire 0.035"
As diameter x length in millimeters (for example 8 x 40 mm), plus the shaft or working length in centimeters and the guidewire it runs on (0.014, 0.018 or 0.035 inch). Longer shafts reach farther from the access site.
A compliant balloon keeps growing as pressure rises; a non-compliant balloon holds its labeled diameter even at high pressure, which suits resistant lesions such as dialysis access stenoses.
A balloon coated with a drug, usually paclitaxel, that is pressed into the vessel wall during angioplasty to reduce re-narrowing. Indications and approvals differ by device and country.
We list 25 product lines of 0.035 pta balloons registered with the FDA, from manufacturers including EV3, Inc, Bard Peripheral Vascular, Inc., Lutonix, Inc., Cordis US Corp., Natec Medical Ltd.
Open a product and use Where to buy: it lists the manufacturer's website, contact and distributor pages and any reps who cover your country. Approvals such as the CE mark vary by country, so confirm availability with the manufacturer.
From the FDA Global Unique Device Identification Database, which lists every model and its labeled sizes. Attributes such as coating or covering come from the FDA text, the manufacturer's own pages, or the manufacturer directly; always confirm with the instructions for use.
Manufacturers can correct their products by claiming their company page. Anyone can send a sourcing request and we will look into it.
Sizes from the FDA Global Unique Device Identification Database (GUDID). Always confirm sizes, compatibility and approval in your country with the manufacturer's instructions for use.
One email a month: new FDA clearances, recalls and device pages in vascular & interventional radiology.
We'll email you a link to confirm. Unsubscribe any time.